The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

6076–6100 of 7643

  • SevereNHTSA·13V209000·2013-05-17

    Elite Recalls 2012 Livestock Trailers Due to Brake Actuator Wear

    Elite Trailer Manufacturing is recalling 2012 Livestock Gooseneck trailers because a manufacturing defect in the hydraulic brake actuator could cause a loss of braking ability.

    Product
    ELITE — ELITE LIVESTOCK TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V214000·2013-05-17

    Pierce Emergency Vehicles Recalled for Door Handle Spring Defect

    Pierce is recalling 2007-2013 Velocity, Impel, and Dash CF emergency vehicles because door handle springs may be too weak to prevent doors from opening in a crash.

    Product
    PIERCE — PIERCE VELOCITY, IMPEL, DASH CF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V206000·2013-05-16

    Isuzu Recalls 2013 N-Series Trucks Due to Transmission Defect

    Isuzu is recalling 1,161 model year 2013 N-Series trucks because a transmission retaining ring may dislodge, potentially causing the vehicle to stall and increasing crash risk.

    Product
    ISUZU — ISUZU N-SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V225000·2013-05-15

    GM Recalls 2011-2013 Chevrolet Express and GMC Savana Vans for Fire Risk

    General Motors is recalling 2011-2013 Chevrolet Express and GMC Savana vans with factory-installed CNG systems due to a corroding fuel connector that may cause a fire.

    Product
    GMC — GMC, CHEVROLET SAVANA, EXPRESS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V204000·2013-05-15

    John Evans Recalls 2013-2014 Chassis and Trailers for Lug Nut Torque Defect

    John Evans is recalling 380 model year 2013-2014 chassis and trailers because wheel lug nuts may not be properly torqued, posing a crash risk.

    Product
    JOHN EVANS — JOHN EVANS, CHEETAH RMFD CHASSIS/TRAILER, CHASSIS/TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V199000·2013-05-14

    Starcraft Allstar Buses Recalled for Wheelchair Lift Cable Fire Risk

    Starcraft is recalling 2006-2012 Allstar buses because a wheelchair lift cable may not clear the lift, potentially causing a short circuit and fire.

    Product
    STARCRAFT — STARCRAFT ALLSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V197000·2013-05-14

    Gulf Stream Motorhomes Recalled for Electrical Wiring Fire Risk

    Gulf Stream is recalling 2001 model year motorhomes because improperly secured electrical wiring may cause wear, heat, and potential fire or injury.

    Product
    GULF STREAM — GULF STREAM ULTRA SUPREME, CONQUEST, ULTRA, CAVALIER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V191000·2013-05-13

    New Heights Recalls Equipter RB4000 Dump Trailers for Brake Defect

    New Heights LLC is recalling Equipter RB4000 dump trailers manufactured in December 2011 because a defective hydraulic brake actuator could cause a loss of braking ability.

    Product
    SERVICE BRAKES, HYDRAULIC recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V194000·2013-05-13

    Subaru Recalls 2013 Outback and Legacy for Steering Column Defect

    Subaru is recalling 2013 Outback and Legacy vehicles because the steering column shafts may disengage, causing loss of steering control.

    Product
    SUBARU — SUBARU OUTBACK, LEGACY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V196000·2013-05-13

    Maserati Recalls 2005-2008 Models for Rear Tie Rod Corrosion Risk

    Maserati is recalling 7,438 vehicles due to insufficient anti-corrosion material on rear tie rods, which may weaken and fail, increasing crash risk.

    Product
    MASERATI — MASERATI, ALFA ROMEO QUATTROPORTE, 8C, GRANTURISMO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V187000·2013-05-09

    KME Emergency Vehicles Recalled for Steering Column Grease Fitting Defect

    Kovatch is recalling specific KME emergency vehicles because a grease fitting in the steering column may tear the cover, potentially causing a loss of steering control.

    Product
    KME — KME PREDATOR SS, ARFF, PREDATOR, PANTHER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V188000·2013-05-09

    Magic Tilt Boat Trailer Hydraulic Brake Actuator Recall

    Magic Tilt is recalling boat trailers with defective hydraulic brake actuators that may fail, causing loss of braking ability and increasing crash risk.

    Product
    SERVICE BRAKES, HYDRAULIC recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V182000·2013-05-08

    Spartan Motorhome Chassis Recall for Steering Bracket Cracking

    Spartan Motors is recalling 2006-2011 K2, K3, and MM motorhome chassis because steering brackets may crack and detach, causing loss of steering.

    Product
    SPARTAN — SPARTAN K3, K2, MM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V185000·2013-05-08

    Temsa Recalls TS35C Coach Buses Due to Fuel Tank Leak Risk

    Temsa is recalling 172 model year 2011-2013 TS35C coach buses because a production error may cause the fuel tank to leak, posing a fire risk.

    Product
    TEMSA — TEMSA TS35C
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V184000·2013-05-08

    Autocar Recalls 2005-2013 Trucks Due to Missing Air Brake Drain Valves

    Autocar is recalling 82 model year 2005-2013 ACX, WX, and WXLL trucks because their air brake systems lack required drain valves, potentially reducing brake performance.

    Product
    AUTOCAR — AUTOCAR WXLL, WX, ACX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V175000·2013-05-07

    Chrysler Recalls Jeep Grand Cherokee and Commander for Electrical Defect

    Chrysler is recalling 2005-2010 Jeep Grand Cherokee and 2006-2010 Jeep Commander vehicles because an electrical failure may cause the transfer case to shift into neutral, increasing crash risk.

    Product
    JEEP — JEEP GRAND CHEROKEE, COMMANDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V179000·2013-05-07

    Lion Bus Recalls One 2014 Model 360 Bus for Brake Line Chafing

    Lion Bus is recalling one 2014 model year 360 bus because the air compressor and hydraulic brake lines may chafe, causing a hole in the brake line and increasing crash risk.

    Product
    LION — LION 360
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V174000·2013-05-06

    Dutchmen Recalls 2013 Breckenridge RVs Due to Awning Motor Defect

    Dutchmen is recalling 2013 Breckenridge recreational vehicles because an awning motor defect may cause the awning to unfurl unexpectedly, increasing the risk of injury or a crash.

    Product
    BRECKENRIDGE — BRECKENRIDGE BRECKENRIDGE
    Category
    Vehicle
    Distribution
    Distributed nationwide