The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

3401–3425 of 7638

  • SevereNHTSA·18V703000·2018-10-05

    Daimler Trucks Recalls 2018-2019 Models for Loose Brake Caliper Bolts

    Daimler Trucks North America is recalling 2018-2019 Freightliner, Western Star, and FCCC trucks because brake caliper mounting bolts may be insufficiently tightened, increasing crash risk.

    Product
    FREIGHTLINER — FREIGHTLINER, FCCC, WESTERN STAR 114SD, XBS, XCM, XCP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V702000·2018-10-05

    Thomas Built Buses Recalls 2018-2019 Models Due to Brake Caliper Bolts

    Daimler Trucks North America is recalling 2018-2019 Thomas Built school buses because brake caliper mounting bolts may be insufficiently tightened, increasing crash risk.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES SAF-T-LINER EFX, SAF-T-LINER HDX, SAF-T-LINER C2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V704000·2018-10-05

    Hyundai Recalls Ioniq Hybrids for Potential Fire Risk

    Hyundai is recalling 2017-2018 Ioniq Hybrid and 2018 Plug-In Hybrid vehicles because a faulty relay may overheat the rear seat, increasing the risk of a fire.

    Product
    HYUNDAI — HYUNDAI IONIQ HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V684000·2018-10-04

    Toyota Recalls Prius and Prius V for Hybrid System Shutdown Risk

    Toyota is recalling 2010-2014 Prius and 2012-2014 Prius V vehicles because excessive voltage may cause the hybrid system to shut down, increasing crash risk.

    Product
    TOYOTA — TOYOTA PRIUS, PRIUS V
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V694000·2018-10-04

    Suzuki Recalls 2017-2018 Motorcycles for Fuel Pump O-Ring Defect

    Suzuki is recalling 2017-2018 DL650, GSX-R1000, and GSX-S750 motorcycles because a twisted fuel pump O-ring may cause a fuel leak, increasing fire risk.

    Product
    SUZUKI — SUZUKI DL650, GSX-R1000, GSX-S750
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V685000·2018-10-04

    Toyota Recalls 2018-2019 Models for Air Bag Software Defect

    Toyota is recalling specific 2018-2019 Avalon, Sequoia, Tundra, and Avalon Hybrid vehicles because the air bag software may prevent deployment in a crash.

    Product
    TOYOTA — TOYOTA AVALON, SEQUOIA, TUNDRA, AVALON HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V692000·2018-10-03

    MCI Recalls 2018-2019 J4500 Motorcoaches for Emergency Exit Window Defect

    Motor Coach Industries is recalling 2018-2019 MCI J4500 motorcoaches with 60-passenger seating due to insufficient emergency egress windows, which may delay passenger exit during an emergency.

    Product
    MCI — MCI J4500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V682000·2018-10-01

    Winnebago Recalls Minnie Drop Trailers Due to Propane Line Fire Risk

    Winnebago is recalling 2017-2019 Minnie Drop trailers because a missing clamp may allow the propane line to contact the refrigerator burner, posing a fire risk.

    Product
    WINNEBAGO — WINNEBAGO MINNIE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V680000·2018-09-28

    BMW Recalls 2019 X6 and X6 M for Rear Suspension Defect

    BMW is recalling 2019 X6 and X6 M vehicles because improperly hardened rear suspension bolts may break, increasing crash risk.

    Product
    BMW — BMW X6, X6 M
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V681000·2018-09-28

    KZRV Sonic Travel Trailer Recall for Propane Manifold Fire Risk

    KZRV is recalling 2017-2019 Sonic 190VRB travel trailers because the liquid propane manifold may be located close to the axle tube, posing a fire risk.

    Product
    KZRV — KZRV SONIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalNHTSA·18V662000·2018-09-27

    Honda Recalls 2010-2014 Vehicles for Air Bag Inflator Explosion Risk

    Honda is recalling 2010-2014 Ridgeline, Element, and Acura RL vehicles because the passenger air bag inflator may explode, posing a risk of serious injury or death.

    Product
    ACURA — ACURA, HONDA RL, RIDGELINE, ELEMENT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V678000·2018-09-27

    Forest River Recalls 2019 Flagstaff and Rockwood Trailers for Brake Defect

    Forest River is recalling 2019 Flagstaff and Rockwood recreational trailers because incorrectly oriented brake mounting flanges may cause premature brake failure, increasing crash risk.

    Product
    FOREST RIVER — FOREST RIVER FLAGSTAFF, ROCKWOOD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V661000·2018-09-27

    Honda Recalls Vehicles for Frontal Air Bag Inflator Explosion Risk

    Honda is recalling specific 2010-2015 models because the passenger frontal air bag inflator may explode, potentially causing serious injury or death.

    Product
    HONDA — HONDA, ACURA ACCORD, CROSSTOUR, FCX CLARITY, INSIGHT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V670000·2018-09-26

    Nova Bus Recalls 2017 LFS Hybrid Buses for Transmission Defect

    Nova Bus is recalling 2017 LFS Hybrid and LFS Arctic Hybrid buses because pressure switches may fail, causing a loss of drive and increasing crash risk.

    Product
    NOVA BUS — NOVA BUS LFS, LFS ARTIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V677000·2018-09-26

    Daimler FCCC MC Motorhome Chassis Recall for Air Gauge Line Misconnection

    Daimler Trucks North America is recalling 2017-2019 FCCC MC motorhome chassis because primary and secondary air lines were incorrectly connected to the pressure gauges, increasing crash risk.

    Product
    FCCC — FCCC MC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V669000·2018-09-25

    Maintainer Service Mechanic Bodies Recalled for Driveshaft Interference Risk

    Maintainer is recalling 2017-2018 Service Mechanic Bodies mounted on Ford F-Series Super Duty trucks because a hydraulic pump may interfere with the front axle driveshaft, potentially causing separation and increasing crash risk.

    Product
    MAINTAINER — MAINTAINER SERVICE/MECHANICBODY FORD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V668000·2018-09-25

    Volvo Recalls VNL Trucks Due to Fuel Line Burst Risk

    Volvo is recalling 2016-2019 VNL trucks with Cummins ISX15 engines because a restricted fuel pump cooling circuit screen may cause the fuel line to burst.

    Product
    VOLVO — VOLVO VNL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V667000·2018-09-25

    Suzuki Recalls 2006 Grand Vitara for Power Steering Belt Tensioner Defect

    Suzuki is recalling 2006 Grand Vitara vehicles because a plastic component in the power steering system can deteriorate, potentially causing a loss of steering assist and increasing crash risk.

    Product
    SUZUKI — SUZUKI GRAND VITARA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V666000·2018-09-25

    Kia Recalls 2017-2018 Niro Hybrids for Fire Risk

    Kia is recalling 2017-2018 Niro hybrid vehicles because a faulty relay may overheat the rear seat, increasing the risk of a fire.

    Product
    KIA — KIA NIRO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V658000·2018-09-24

    Grand Design Recalls 2019 Travel Trailers Due to Axle Bearing Defect

    Grand Design is recalling 2019 Reflection, Imagine, and Transcend travel trailers because missing inner axle bearings may cause overheating and fire.

    Product
    GRAND DESIGN — GRAND DESIGN TRANSCEND, REFLECTION, IMAGINE
    Category
    Vehicle
    Distribution
    Distributed nationwide