The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

20726–20750 of 40339

  • HighFDA (Devices)·Z-1634-2019·2019-06-05

    Maquet Cardiovascular Recalls Custom Tubing Sets for Extracorporeal Circulation

    Maquet Cardiovascular is recalling custom tubing sets for extracorporeal circulation because a design flaw may prevent sterilization gas from reaching all parts of the device.

    Product
    Maquet Getinge-BEQ-TOP 21502 ECC Quadrox iD w/RF 3/8" Material:701050060R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1681-2019·2019-06-05

    King LTS-D Kit Size 1 Recalled for Incorrect Packaging and Labeling

    King Systems Corp. dba Ambu, Inc. is recalling 270 King LTS-D Kit Size 1 units because they were incorrectly packaged and labeled as size 1 products.

    Product
    King LTS-D Kit Size 1, Model Number KLTSD431
    Category
    Medical Device
    Distribution
    11 states
  • ModerateFDA (Devices)·Z-1492-2019·2019-06-05

    K2M Fenestrated Tap Adapter Recalled for Mislabeled Packaging

    K2M, Inc. is recalling 462 Fenestrated Tap Adapters because the products are mislabeled. The devices are used for bone biopsies and vertebral body augmentation.

    Product
    Fenestrated Tap Adapter (REF# 5001-90011) Product Usage: The K2M Fenestrated Tap System is intended for use as a standalone biopsy tool to remove a sample of bone tissue from a vertebral body for diagnostic purposes using an aspiration technique, as well as to provide and…
    Category
    Medical Device
    Distribution
    6 states
  • ModerateFDA (Devices)·Z-1686-2019·2019-06-05

    Teleflex Medical Recalls RUSCH LASERTUBE Due to Partial Foil Separation

    Teleflex Medical is recalling 2,325 units of RUSCH LASERTUBE (Rubber) because the laser guard foil partially separated or detached at the edges.

    Product
    RUSCH LASERTUBE (Rubber), Order No. : 102004-000080, REF 102004, SIZE I.D. mm 8,0
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1690-2019·2019-06-05

    Exactech Recalls Opteform Allograft Discs Due to Cold Storage Failure

    Exactech is recalling three units of Opteform Allograft Discs because they were potentially exposed to higher temperatures than documented due to cold storage equipment failure.

    Product
    Opteform Allograft Disc, 90mm x 5mm, 22cc, Catalog Number 600-03-90
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-1688-2019·2019-06-05

    Exactech Recalls Opteform Allograft Discs Due to Cold Storage Failure

    Exactech is recalling two units of Opteform Allograft Discs because they were potentially exposed to higher temperatures than documented due to a cold storage equipment failure.

    Product
    Opteform Allograft Disc, 30mm 3mm, 2cc, Catalog Number 600-03-30
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-1689-2019·2019-06-05

    Exactech Recalls Opteform Allograft Discs Due to Cold Storage Failure

    Exactech, Inc. is recalling two units of Opteform Allograft Discs because they were potentially exposed to higher temperatures than documented due to a cold storage equipment failure.

    Product
    Opteform Allograft Disc, 45mm x 5mm, 8cc, Catalog Number 600-03-45
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-1491-2019·2019-06-05

    K2M Fenestrated Taps Recalled for Mislabeled Packaging

    K2M, Inc. is recalling 462 Fenestrated Taps because the products are mislabeled. The devices were distributed to six US states.

    Product
    Fenestrated Taps 4.5mm, 5.5mm, 6.5mm (Ref#5001-90013, 5001-90014, 5001-90015) Product Usage: The K2M Fenestrated Tap System is intended for use as a standalone biopsy tool to remove a sample of bone tissue from a vertebral body for diagnostic purposes using an aspiration…
    Category
    Medical Device
    Distribution
    6 states
  • SevereFDA (Devices)·Z-1311-2019·2019-05-29

    Integra MoniTorr CSF Drainage System Recalled for Stopcock Breakage

    Integra LifeSciences is recalling MoniTorr CSF Drainage Systems due to a complaint trend regarding stopcock breakage.

    Product
    MoniTorr INS1100 INS-1100 CSF Drainage System used with Pole Mount System Product Usage: The MoniTorr ICP External CSF Drainage and Monitoring Systems provide a simple to use, closed system for the drainage of cerebrospinal fluid (CSF) from ventricles of the brain or the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1193-2019·2019-05-29

    Edwards Lifesciences Recalls EV1000 Clinical Platform Due to Fire Hazard

    Edwards Lifesciences is recalling EV1000 Clinical Platform monitors because liquid ingress into AC power outlets could cause an electrical short circuit and fire.

    Product
    EV1000 Clinical Platform, Models: EV1000A, EV1000NI, EV1000CS Product Usage: EV1000A Monitor is used to optimize fluid management through the use of minimally invasive monitoring with the FloTrac sensor (or the Volume View sensor).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1312-2019·2019-05-29

    Integra LifeSciences Recalls LimiTorr and MoniTorr Stopcock Components

    Integra LifeSciences is recalling LimiTorr and MoniTorr stopcock components due to a complaint trend regarding breakage.

    Product
    LimiTorr INS9020 INS-9020 LIMITORR VOLUME LIMITING EVD 20 ML LimiTorr INS9020SP1 INS-9020SP1 LIMITORR VOLUME EVD 20ML LimiTorr INS9030 INS-9030 LIMITORR VOLUME LIMITING EVD 30 ML LimiTorr INS9030SP1 INS-9030SP1 LIMITORR VOLUME LIMITING EVD 30 ML Product Usage: The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1383-2019·2019-05-29

    Beckman Coulter Recalls UniCel DxH 600 Hematology Analyzers for Platelet Errors

    Beckman Coulter is recalling 2,059 UniCel DxH 600 hematology analyzers because they may produce erroneously elevated platelet results without warning, potentially masking low platelet counts.

    Product
    UniCel DxH 600 Coulter Cellular Analysis System, REF number B23858. Product Usage: Note: The DxH 600 hematology analyzer is the same instrument as the DxH 800 (K140911), except that it is a benchtop unit with no instrument cart, computer stand, and no connectivity…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1382-2019·2019-05-29

    Beckman Coulter UniCel DxH 800 Hematology Analyzer Recall for Platelet Errors

    Beckman Coulter is recalling UniCel DxH 800 analyzers because sporadic platelet results may be erroneously elevated without system flags, potentially leaving thrombocytopenia unrecognized.

    Product
    UniCel DxH 800 Coulter Cellular Analysis System, REF numbers 629029, B24465, B24802, B68304, B66445, and B63322. Product Usage: The UniCel DxH 800 Analyzer is a quantitative multi-parameter, automated hematology analyzer for in vitro diagnostic use in screening patient…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1310-2019·2019-05-29

    Integra LifeSciences Recalls MoniTorr CSF Drainage Systems Due to Stopcock Breakage

    Integra LifeSciences is recalling MoniTorr CSF Drainage Systems because the LimiTorr Transducer Mount and MoniTorr Panel Mount stopcocks may break.

    Product
    MoniTorr 10100 10-100 CSF Drainage System w/Patient Line One Way Valve MoniTorr 10102 10-102 CSF Drainage System w/Patient Line One Way Valve w MoniTorr 10110 10-110 CSF Drainage System used with Pole Mount System MoniTorr 10140 10-140 CSF Drainage System w/Vinyl Measuring…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1384-2019·2019-05-29

    Beckman Coulter UniCel DxH 900 Hematology Analyzer Recall for Platelet Errors

    Beckman Coulter is recalling 341 UniCel DxH 900 hematology analyzers because they may produce erroneously elevated platelet results without warning, potentially masking low platelet counts.

    Product
    UniCel DxH 900 Coulter Cellular Analysis System, REF number C11478 Product Usage: Note: The DxH 900 hematology analyzer is CLIA categorized under document CR180294 and is currently marketed as a member of the instrument family of the DxH 800 cleared under K140911, per FDA s…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1364-2019·2019-05-29

    Ortho-Clinical VITROS XT 7600 System Recalled for Potential Sample Dispensing Errors

    Ortho-Clinical Diagnostics is recalling VITROS XT 7600 Integrated Systems because sample fluid may be dispensed to incorrect positions, potentially causing erroneous assay results.

    Product
    VITROS XT 7600 Integrated System, with V3.4 or 3.4.1 SW Product Code: 6844461 Product Usage: INTENDED USE: For in vitro diagnostic use only. The VITROS XT 7600 Integrated System is intended for use in the measurement of a variety of analytes of clinical interest
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1381-2019·2019-05-29

    Dornier Diode Laser Fibers Recalled for Sterility Compromise

    Dornier Medtech America is recalling 400 units of Dornier Diode Laser Fibers due to pin hole package failures that compromise product sterility.

    Product
    Dornier Diode Laser Fibers:Used with Dornier Medilas D Family Lasers Part Number/Description: K1001291 600 micron single use fiber K2011824 600 micron single use fiber K1001293 600 micron single use fiber K2011826 600 micron 5X reusable fiber K1008084 600 micron single use…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1411-2019·2019-05-29

    Oakworks Lithotripsy Table Recalled for Incorrect Actuator Assembly Error

    Oakworks Inc. is recalling three Lithotripsy/Urology Tables due to an assembly error involving incorrect actuators for lateral and longitudinal movements.

    Product
    OAKWORKS Inc.Lithotripsy/Urology Table: CFLU401, Catalog Number: 75216-T01 - Product Usage: Oakworks¿ Imaging Tables are radiographic tables intended for use with mobile or compact stationary C-arm Imaging Systems. It is ideally suited for pain management imaging and therapeutic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1431-2019·2019-05-29

    Zimmer GmbH Recalls Osteofresh Arthrodesis Drills Due to Material Concerns

    Zimmer GmbH is recalling specific Osteofresh arthrodesis drills because they may have been manufactured from a material different from the specifications.

    Product
    Osteofresh arthrodesis drill, 2x70mm, center tip, AO, 10mm stop, Item Number 502015213
    Category
    Medical Device
    Distribution
    42 states
  • HighFDA (Devices)·Z-1373-2019·2019-05-29

    Polymer Technology Systems Recalls CHOL+HDL+GLU Test Strips

    Polymer Technology Systems is recalling CHOL+HDL+GLU test strips because they may not fit tightly into the optical block, potentially causing incorrect results.

    Product
    CHOL+HDL+GLU test strips, REF 2412
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1488-2019·2019-05-29

    Zimmer GmbH Recalls Cannulated Orthopedic Screws Due to Material Concerns

    Zimmer GmbH is recalling specific cannulated orthopedic screws because they may have been manufactured from a material different from specifications.

    Product
    CBS high, countersink, cannulated, AO, Item Number ST503004542
    Category
    Medical Device
    Distribution
    42 states
  • HighFDA (Devices)·Z-1371-2019·2019-05-29

    Polymer Technology Systems Recalls Lipid Panel Test Strips Due to Fit Issues

    Polymer Technology Systems is recalling Lipid Panel test strips because they may not fit tightly into the optical block, potentially causing incorrect results.

    Product
    Lipid Panel test strips, REF 1710, also private labeled under Henry Schein as REF 570-0414
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1470-2019·2019-05-29

    Zimmer GmbH Recalls 2.7mm AO Surgical Drills Due to Material Concerns

    Zimmer GmbH is recalling specific 2.7mm AO surgical drills because they may be made from a different material than specified. The products were distributed to 41 US states.

    Product
    Drill for 2.7mm screw, 2x100mm, AO, Item Number ST502015208
    Category
    Medical Device
    Distribution
    42 states
  • HighFDA (Devices)·Z-1463-2019·2019-05-29

    Zimmer V-TEK Cannulated AO Screws Recalled for Material Deviation

    Zimmer GmbH is recalling V-TEK standard-countersink cannulated AO screws because they may have been manufactured from a different material than specified.

    Product
    V-TEK", standard-countersink, cannulated, AO, Item Number 28.66.111
    Category
    Medical Device
    Distribution
    42 states
  • HighFDA (Devices)·Z-1434-2019·2019-05-29

    Zimmer GmbH Recalls Stryker 3.5mm Screw Drills Due to Material Concerns

    Zimmer GmbH is recalling Stryker 3.5mm screw drills because they may have been manufactured from a different material than specified.

    Product
    Drill for 3.5mm screw, 2.5x125mm, stryker, Item Number 502015218
    Category
    Medical Device
    Distribution
    42 states