The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

17101–17125 of 40287

  • HighFDA (Devices)·Z-2262-2020·2020-06-17

    Ventana HE 600 Recalled for Electrical Short Risk

    Ventana Medical Systems is recalling 461 HE 600 instruments due to a cleaning solution leak that can cause electrical shorts and burned components.

    Product
    Model Number: 06917259001 UDI: 04015630976010 - Product Usage: The System s intended use environment includes anatomic pathology (AP) laboratories and histology facilities within hospital, clinic, reference, or private lab settings. The System is to be operated by qualified…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2332-2020·2020-06-17

    Smith & Nephew Recalls R3 Acetabular Shells Due to Manufacturing Error

    Smith & Nephew is recalling 1,450 R3 Zero Hole HA Coated Hemispherical Stiktite Coated Shells because a manufacturing error resulted in out-of-specification devices.

    Product
    smith&nephew R3 ZERO HOLE HA COATED HEMISPHERICAL STIKTITE COATED SHELL, manufactured in the following sizes: Size REF/product number 42MM 71332242 46MM 71332246 48MM 71332248 50MM 71332250 52MM 71332252 54MM 71332254 56MM 71332256 58MM 71332258 60MM 71332260 62MM…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2296-2020·2020-06-17

    BioFire FilmArray BCID Panel Recalled for False Positive Proteus Results

    BioFire Diagnostics is recalling FilmArray BCID Panels due to a risk of false positive Proteus results when used with specific blood culture media, which may lead to improper antibiotic treatment.

    Product
    FilmArray BCID Panel, RFIT-ASY-0127, 6, Rx Only, CE, IVD, UDI: 00815381020093 used with the following BACT/ALERT Blood Culture Bottle Catalog No./Description: 410851/BACT/ALERT¿ FA Plus 410852/BACT/ALERT¿ FN Plus 410853/BACT/ALERT¿ PF Plus 259790/BACT/ALERT¿ SN…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2297-2020·2020-06-17

    Elekta Unity Software Recall for Motion Monitoring Data Mismatch

    Elekta Limited is recalling specific Unity software versions due to a potential mismatch between contour data and motion monitoring images.

    Product
    Elekta Unity, Philips Marlin Software versions: R5.3.30, R5.3.31, R6.0.5331, R5.7.0, R5.7.1, R6.1.571
    Category
    Medical Device
    Distribution
    5 states
  • HighFDA (Devices)·Z-2355-2020·2020-06-17

    Acuity Surgical Devices Recalls A Link Z Intervertebral Body Fusion Devices

    Acuity Surgical Devices is recalling A Link Z Intervertebral Body Fusion Devices due to a manufacturing issue that may prevent vertebral body bone screws from seating properly.

    Product
    A LINK Z INTERVERTEBRAL BODY FUSION DEVICE Product Description: A Link Z Ti Unitary Open Interbody 32x24x12 7 A Link Z Ti Unitary Open Interbody 32x24x12 12 A Link Z Ti Unitary Open Interbody 32x24x16 7 A Link Z Ti Unitary Open Interbody 32x24x16 12 Product Usage: is a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2298-2020·2020-06-17

    HardyCHROM MRSA Recall for False Positive Results

    Hardy Diagnostics is recalling HardyCHROM MRSA kits because they may produce false positive results for methicillin-susceptible Staphylococcus aureus.

    Product
    HardyCHROM MRSA,REF; G307, LOT: 447694, A selective and differential chromogenic medium for the qualitative direct detection of nasal colonization by methicillin-resistant Staphylococcus aureus (MRSA). Not intended to diagnose infection of guide therapy. Further testing required…
    Category
    Medical Device
    Distribution
    15 states
  • HighFDA (Devices)·Z-2284-2020·2020-06-17

    Siemens Dimension Enzymatic Creatinine Recalled for Acetaminophen Interference

    Siemens Healthcare Diagnostics is recalling Dimension Enzymatic Creatinine reagents because acetaminophen metabolites may interfere with test results.

    Product
    Dimension Enzymatic Creatinine, Siemens Material Number 10471520, UDI Number 00842768030512 - Product Usage: use in the quantitative determination of creatinine in human serum, plasma, and urine for the diagnosis and treatment of renal disease.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2325-2020·2020-06-17

    Canon Medical System Recalls Infinix-8000V Catheterization Tables Due to Loose Bolts

    Canon Medical System is recalling 46 Infinix-8000V systems because loose bolts may cause the catheterization table to tilt.

    Product
    Infinix-8000V with Catheterization Table CAT-850B or CAT-860B - Product Usage: This device is a digital radiography/fluoroscopy system used in a diagnostic and interventional angiography configuration. The system is indicated for use in diagnostic and angiographic procedures for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2285-2020·2020-06-17

    Siemens Dimension Vista Enzymatic Creatinine Recalled for Acetaminophen Interference

    Siemens Healthcare Diagnostics is recalling Dimension Vista Enzymatic Creatinine test kits because acetaminophen metabolites may interfere with results.

    Product
    Dimension Vista Enzymatic Creatinine, Siemens Material Number 10700444, UDI Number 00842768036262 - Product Usage: use in the quantitative determination of creatinine in human serum, plasma, and urine for the diagnosis and treatment of renal disease.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2275-2020·2020-06-17

    Genicon Natura Trocar Handle Recall Due to Detaching Optical Tip

    Genicon, Inc. is recalling Natura Model 210-005-152 trocar handles because the plastic optical tip may detach from the metal shaft.

    Product
    Genicon Natura Model 210-005-152, 5mm diameter, 100mm length (two cannula, threaded) - Product Usage: The universal handle can be used as a pistol grip or like a traditional Trocar handle when using a scope.
    Category
    Medical Device
    Distribution
    7 states
  • HighFDA (Devices)·Z-2339-2020·2020-06-17

    RayStation Radiation Therapy Software Recalled for Dose Calculation Error

    RaySearch Laboratories is recalling RayStation software versions 4.0 to 5.0 Service Pack 2 due to a dose calculation error that may underestimate radiation dose.

    Product
    RayStation 4.0 to RayStation 5 Service Pack 2 - Product Usage: For radiation therapy and medical oncology which can also be used to administer treatments.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2302-2020·2020-06-17

    Siemens Artis X-Ray Systems Recalled for Electrical Contact Issues

    Siemens is recalling 15 Artis X-ray systems in the US because a power distributor defect may cause electrical contact interruptions, leading to procedure termination.

    Product
    Multi Display Manager in the Artis Systems (Image-Intensified Fluoroscopic X-Ray System) as follows: Artis Q floor Model: 10848280; Artis Q ceiling Model: 10848281; Artis Q biplane Model:10848282; Artis zee ceiling Model: 10094137; Artis zee floor Model…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2327-2020·2020-06-17

    Canon Medical System Recalls Infinix-8000F Fluoroscopy Systems Due to Loose Bolts

    Canon Medical System is recalling 15 Infinix-8000F digital radiography systems because loose bolts may cause the catheterization table to tilt.

    Product
    Infinix-8000F with Catheterization Table CAT-850B or CAT-860B - Product Usage: This device is a digital radiography/fluoroscopy system used in a diagnostic and interventional angiography configuration. The system is indicated for use in diagnostic and angiographic procedures for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2328-2020·2020-06-17

    Intuitive Surgical Recalls 8mm Endoscope Sterilization Trays Due to Sterility Risk

    Intuitive Surgical is recalling 1,757 stainless steel reprocessing trays because holes in the sterilization wrap could compromise sterility and increase infection risk.

    Product
    STAINLESS STEEL REPROCESSING TRAY, 8MM ENDOSCOPE, IS4000, Model No. 400498-02 - Product Usage: is designed to enable complex surgery using a minimally invasive approach.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2300-2020·2020-06-17

    Biomet Recalls Comprehensive VRS Inserter Shoulder Prosthesis Devices

    Biomet is recalling 38 Comprehensive VRS Inserter shoulder prosthesis devices because the central screw drill may seize, potentially extending surgery time.

    Product
    Comprehensive VRS Inserter, shoulder prosthesis, Item No. 110019068. UDI: (01)00880304829503 (10)814100, (01)00880304829503 (10)570640, (01)00880304829503 (10)728890, (01)00880304829503 (10)977300
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2272-2020·2020-06-17

    Genicon GENILook Cannula Recalled Due to Detaching Optical Tip

    Genicon, Inc. is recalling GENILook Model 200-105-251 cannulas because the plastic optical tip may detach from the metal shaft.

    Product
    Genicon GENILook Model 200-105-251, 5mm diameter, 150mm length (1 cannula) - Product Usage: The universal handle can be used as a pistol grip or like a traditional Trocar handle when using a scope.
    Category
    Medical Device
    Distribution
    7 states
  • HighFDA (Devices)·Z-2344-2020·2020-06-17

    RayStation 8A Radiation Therapy Software Recalled for Dose Calculation Error

    RaySearch Laboratories is recalling RayStation 8A software due to a defect in dose calculation algorithms that may underestimate radiation dose.

    Product
    RayStation 8A, UDI # 07350002010112 - Product Usage: For radiation therapy and medical oncology which can also be used to administer treatments.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2269-2020·2020-06-17

    Genicon GENILook Cannula Recalled for Potential Tip Detachment

    Genicon, Inc. is recalling GENILook Model 200-005-251 cannulas because the plastic optical tip may detach from the metal shaft.

    Product
    Genicon GENILook Model 200-005-251, 5mm diameter, 150mm length (one cannula, threaded) - Product Usage: The universal handle can be used as a pistol grip or like a traditional Trocar handle when using a scope.
    Category
    Medical Device
    Distribution
    7 states
  • ModerateFDA (Devices)·Z-2313-2020·2020-06-17

    Biomet Recalls Proximal Humerus Plate Templates Due to Incomplete Design History

    Biomet is recalling A.L.P.S. Proximal Humerus Plate Templates because they were distributed without completed design history files or design transfer activities.

    Product
    A.L.P.S.¿ PROXIMAL HUMERUS PLATING SYSTEM PROXIMAL HUMERUS PLATE TEMPLATE 140MM Item Number: 110025472 - Product Usage: Intended for temporary internal fixation and stabilization of osteotomies and fractures during the normal healing process.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2357-2020·2020-06-17

    BD FACS Sample Prep Assistant II Upgrade Recalled for Probe Wear

    Becton, Dickinson and Company is recalling 51 units of the BD FACS Sample Prep Assistant II Upgrade due to premature probe wear that may cause sample dispensing issues.

    Product
    BD FACS Sample Prep Assistant (SPA) II Upgrade - Product Usage: K050191: The BD FACSCanto system with BD FACSCanto clinical software when used with the BD FACS Sample Prep Assistant II /III is intended for use as an in vitro diagnostic device for identification and enumeration…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2280-2020·2020-06-17

    Siemens ADVIA Chemistry Fructosamine Reagent Recalled for Potential Interference

    Siemens is recalling ADVIA Chemistry Fructosamine Reagent because acetaminophen metabolites may interfere with test results, potentially affecting diabetic patient monitoring.

    Product
    ADVIA Chemistry Fructosamine Reagent (FRUC), Siemens Material Number 10361941, UDI Number 00630414558073 - Product Usage: use in the quantitative measurement of glycated protein (fructosamine) in human serum and plasma for monitoring the blood glucose levels of diabetic patients…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2286-2020·2020-06-17

    Ormco Damon Q2 Orthodontic Bracket Recalled for Packaging Labeling Error

    Ormco/Sybronendo is recalling 2,189 units of Damon Q2 Orthodontic Metal Brackets because the bracket torque was mislabeled on the packaging.

    Product
    Ormco Damon Q2 Orthodontic Metal Bracket, Part No. 491-9834, L3R Hi Tq Hook, Tq +13 degrees, Rx. Manufactured by Ormco Corporation, This device is intended for use for the orthodontic movement of teeth. It is used temporarily and is removed after orthodontic treatment has…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2292-2020·2020-06-17

    Olympus ENF-GP2 Fiberscope Recalled for Missing O Ring

    Olympus is recalling 19 ENF-GP2 Rhino-Laryngo Fiberscopes because they may be missing an O ring after being repaired with an incorrect service manual.

    Product
    ENF-GP2 Rhino-Laryngo Fiberscope - Product Usage: is indicated for use within the nasal and nasopharyngeal lumen.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2312-2020·2020-06-17

    Biomet Recalls Proximal Humerus Plate Templates Due to Incomplete Design History

    Biomet is recalling 78 units of A.L.P.S. Proximal Humerus Plate Templates because they were distributed without completed design history files or design transfer activities.

    Product
    A.L.P.S. PROXIMAL HUMERUS PLATING SYSTEM PROXIMAL HUMERUS PLATE TEMPLATE 90MM, Item Number: 110025471 - Product Usage: Intended for temporary internal fixation and stabilization of osteotomies and fractures during the normal healing process.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2315-2020·2020-06-17

    Biomet Recalls Proximal Humerus Plating System Due to Incomplete Design History

    Biomet is recalling A.L.P.S. Proximal Humerus Plating System units because they were distributed without completed design history files or design transfer activities.

    Product
    A.L.P.S.¿ PROXIMAL HUMERUS PLATING SYSTEM LOW PLATE LEFT 11 HOLE 190MM, Item Number: 110030108 - Product Usage: Intended for temporary internal fixation and stabilization of osteotomies and fractures during the normal healing process.
    Category
    Medical Device
    Distribution
    Distributed nationwide