The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

6676–6700 of 27393

  • HighFDA (Devices)·Z-0387-2024·2023-11-29

    Biomet Compress Device Short Anchor Plug recalled for metal burrs

    Biomet is recalling the Compress Device Short Anchor Plug due to metal burrs in transverse holes that may prevent proper insertion of drill or pins, potentially extending surgical time. No injuries have been reported.

    Product
    Compress Device Short Anchor Plug, 26 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178568
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0342-2024·2023-11-29

    Sigmoidovideoscope models recalled due to improper channel drying process

    Aizu Olympus sigmoidovideoscope (model PCF-S) units are being recalled due to an unvalidated channel drying process. Some repaired units returned with water in channels, risking contamination and infection.

    Product
    Signmoidovideoscope-For endoscopy and endoscopic surgery within the lower digestive tract (including the anus, rectum and sigmoid colon). Model Number: PCF-S.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0376-2024·2023-11-29

    Compress Device Anchor Plugs Recalled for Metal Burrs in Surgical Holes

    Biomet is recalling Compress Device Segmental Anchor Plugs due to metal burrs that may prevent surgical instruments from passing through properly. The defect may result in extended surgery time.

    Product
    Compress Device Segmental Anchor Plug, 22 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178412
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0325-2024·2023-11-29

    IRON assay kits recalled for inaccurate diagnostic results

    Sentinel CH SpA is recalling IRON assay kits (Reference Numbers 6K95-41 and 6K95-30) that may produce falsely elevated results. Affected lots could cause inaccurate iron measurements and delays in patient test reporting.

    Product
    IRON assay, Reference Numbers 6K95-41 and 6K95-30
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0389-2024·2023-11-29

    Philips Achieva 1.5T MRI systems recalled for potential gradient coil fire risk

    Philips is recalling Achieva 1.5T MRI systems due to potential gradient coil failure that could produce smoke and/or fire. Approximately 520 units have been distributed nationwide and internationally.

    Product
    Achieva 1.5T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0381-2024·2023-11-29

    Biomet Compress Device Anchor Plugs Recalled for Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs due to metal burrs that may prevent proper surgical installation and extend operation time. Distribution includes US nationwide and eight other countries.

    Product
    Compress Device Short Anchor Plug, 16 MM- Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement Item Number: 178558
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0327-2024·2023-11-29

    Bronchoscopes Recalled Due to Inadequate Air Drying Process

    Aizu Olympus recalls bronchoscopes due to unvalidated air drying process. Some returned units after repair contain water in channels, creating infection risk.

    Product
    Bronchoscope-for endoscopy and endoscopic surgery within the airways and tracheobronchial tree. Model Numbers: BF-1T150, BF-1T60, BF-1TH190, BF-1TQ170, BF-3C160, BF-3C40, BF-H190, BF-MP190F, BF-MP60, BF-P150, BF-P190, BF-P60, BF-Q170, BF-Q190, BF-XP190, BF-XP60, BF-XT160, BF-XT
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0320-2024·2023-11-29

    Medtronic Mo.Ma Ultra cerebral protection device labeling error recalled

    Medtronic is recalling 2,767 units of the Mo.Ma Ultra Proximal Cerebral Protection Device due to labeling errors on the manifold that result in incorrect identification of inflation and deflation ports.

    Product
    Medtronic Mo.Ma Ultra Proximal Cerebral Protection Device, Model Number MUS0130069X6
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0383-2024·2023-11-29

    Biomet Compress Device Anchor Plug Recalled for Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs (20 MM) because metal burrs in transverse holes prevent surgical instruments from passing through, potentially extending surgery time.

    Product
    Compress Device Short Anchor Plug, 20 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178562
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0352-2024·2023-11-29

    Roche Tina-quant D-Dimer Test System Recalled for Inaccurate Results

    Roche is recalling Tina-quant D-Dimer Test System kits because they produce elevated results when used with lithium-heparin plasma samples, potentially affecting diagnostic accuracy.

    Product
    Tina-quant D-Dimer Test System, Fibrinogen/Fibrin Degradation Products Assay, Material Numbers 03001245322 - (cobas c 311, 501 and 502; INTEGRA 400 plus), 08105618190 - (cobas c 303 and 503)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0391-2024·2023-11-29

    Philips Achieva 1.5T MRI Systems Recalled for Gradient Coil Fire Risk

    Philips is recalling Achieva 1.5T MRI systems because the gradient coil component could fail and produce smoke or fire. The recall affects 2 units distributed worldwide.

    Product
    Achieva 1.5T Initial System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0341-2024·2023-11-29

    Colonoscopes recalled over unvalidated channel drying process

    Aizu Olympus colonoscopes are being recalled because the air drying process for the instrument channel was not properly validated. Some units returned after repair had moisture in the channel, creating a risk of contamination and infection.

    Product
    Colonoscope-indicated for use within the lower digestive tract (including the anus, rectum, sigmoid colon, colon, and ileocecal valve). Model Numbers: PCF-H180AI, PCF-H180AL, PCF-H190DI, PCF-H190DL, PCF-H190I, PCF-H190L, PCF-H190TI, PCF-H190TL, PCF-HQ190I, PCF-HQ190L, PCF-PH190I
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0397-2024·2023-11-29

    EXALT Model D Single-Use Duodenoscope Recalled for Lens Fluid Ingress

    Boston Scientific is recalling EXALT Model D Single-Use Duodenoscopes due to fluid ingress in the lens, which causes poor image quality during procedures.

    Product
    EXALT Model D Single-Use Duodenoscope, 2 pack: Outer box UPN# M00542421, Inner box UPN # M00542420 & Outer box UPN# M0054242CE1, Inner box UPN # M0054242CE0.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0340-2024·2023-11-29

    Mobile Airway Scope Recalled Due to Unvalidated Drying Process

    Aizu Olympus has recalled 33 Mobile Airway Scope units due to an unvalidated air drying process. Some repaired units had wet channels, creating a potential risk of contamination and infection.

    Product
    Mobile airway scope-diagnosis and observation to access airway anatomy, endotracheal/endobronchial intubation and management. Model Numbers: MAF-DM2, MAF-GM, MAF-GM2, MAF-TM, MAF-TM2.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0359-2024·2023-11-29

    Blood Gas Analyzer Cartridges Recalled for Falsely Elevated Oxygen Readings

    Instrumentation Laboratory recalls GEM Premier 3000 PAK blood gas analyzer cartridges due to measurement errors in low oxygen detection. The devices may falsely indicate normal oxygen levels when levels are dangerously low, potentially delaying treatment.

    Product
    GEM Premier 3000 PAK - pH, pCO2, pO2, Hct, Na+, K+, Ca++, Glucose and Lactate, Part Numbers 00024315009, 00024330009, 00024345009, 00024360009
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0330-2024·2023-11-29

    Choleodochoscope Models Recalled Due to Unvalidated Air Drying Process

    Aizu Olympus choleodochoscopes with unvalidated air drying processes may retain water in the channel after repair, risking microbial contamination and patient infection. Affected models: CHF-BP30, CHF-CB30L, CHF-P60.

    Product
    Choleodochoscope. Model Numbers: CHF-BP30, CHF-CB30L, CHF-P60.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0332-2024·2023-11-29

    Rhinolaryngoscope Models Recalled for Unvalidated Air Drying Process

    Aizu Olympus rhinolaryngoscopes (models ENF-T3, ENF-VT2, ENF-VT3) are recalled. The air-drying process for the instrument channel was not validated, and water remaining in some devices after repair poses contamination and infection risk.

    Product
    Rhinolaryngoscope-for endoscopic diagnosis and treatment within the nasal lumens and airway anatomy (including nasopharyngeal and trachea). Model Numbers: ENF-T3, ENF-VT2, ENF-VT3.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0372-2024·2023-11-29

    Surgical Anchor Plug Devices Recalled for Potential Metal Burrs

    Biomet is recalling Compress Device Segmental Anchor Plugs due to metal burrs in transverse holes that may prevent surgical drill passage and extend surgery time.

    Product
    Compress Device Segmental Anchor Plug, 14 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178404
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0350-2024·2023-11-29

    BD Gravity Infusion Sets Labeled DEHP-Free But Contain DEHP

    BD gravity blood infusion sets labeled as free of DEHP (di(2-ethylhexyl) phthalate) actually contain the substance. The recall affects products distributed worldwide through July 31, 2026.

    Product
    BD gravity sets (Product Name, Catalog #) 32-IN GRAV SET W/0.2 MICRON FILTER BAG ACCESS PORT SS VALVE TEXIUMTM LOW ABSORPTION, Catalog # 4030B-07T and BD GRAVITY BLOOD SET 15 DROP 180 MICRON FILTER SmartSiteTM VALVE NONVENTED, Catalog # 42081E.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0392-2024·2023-11-29

    MRI Machine Gradient Coil Potential Failure Could Produce Smoke and Fire

    Philips Ingenia 1.5T CX MRI systems may experience gradient coil failure that could produce smoke and/or fire. The FDA has classified this as a Class II recall affecting 48 units distributed nationwide and internationally.

    Product
    Ingenia 1.5T CX
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0326-2024·2023-11-29

    Alinity c Iron Reagent Recalled for Falsely Elevated Test Results

    The FDA is recalling Alinity c Iron Reagent lots due to inaccurate results. The reagent produces falsely elevated patient iron values and may prevent proper quality control verification.

    Product
    Alinity c Iron Reagent, Reference Number 08P3920
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0339-2024·2023-11-29

    Tracheal Videoscope Recall Due to Unvalidated Drying Process

    Aizu Olympus is recalling 61 tracheal videoscopes (Model LF-V) due to an unvalidated air drying process that left water in channels after repair. Water in the endoscope channels may become contaminated and pose an infection risk.

    Product
    Tracheal videoscope- For airway management, which includes observation to access airway anatomy, endotracheal/endobronchial intubation and management. Model Number: LF-V.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0360-2024·2023-11-29

    Avanos BALLARD Closed Suction System mislabeled for DEHP content

    Certain lots of AVANOS BALLARD Closed Suction System for Adults were labeled as DEHP-free but contain DEHP in tubing components. These units are used for mechanical ventilation and distributed in the US and South Africa.

    Product
    AVANOS BALLARD Closed Suction System for Adults, 14 Fr, DSE, MDI, Product code 221038, provide suction on patients on mechanical ventilation
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0328-2024·2023-11-29

    Ultrasonic Bronchoscopes Recalled Due to Inadequate Drying Validation

    Aizu Olympus is recalling 823 ultrasonic bronchoscopes (models BF-UC180F, BF-UC190F) because the channel air drying process was not validated, and some repaired units retained water that could cause contamination and infection.

    Product
    Bronchoscope - Ultrasonic: endoscopic real-time ultrasonic imaging, ultrasound guided needle aspiration and other endoscopic procedures within the airways, trancheobronchial tree, esophagus and surrounding organs Model Numbers: BF-UC180F, BF-UC190F.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0353-2024·2023-11-29

    BioFire FilmArray TORCH power switch may fail from electrical arcing

    BioFire FilmArray TORCH diagnostic devices have a power switch that may degrade from internal arcing and carbon buildup, potentially causing electrical short, device overheating, or failure to power on.

    Product
    FilmArray TORCH REF HTFA-ASY-0104. HTFA-ASY-0104 is the BIOFIRE TORCH Base which includes barcode scanner, touch screen computer and USB ports. The BioFire FilmArray Torch (BioFire Torch) is an automated in vitro diagnostic (IVD) device intended for use with FDA-cleared or ap
    Category
    Medical Device
    Distribution
    Distributed nationwide