The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

25851–25875 of 27722

  • HighFDA (Devices)·Z-0182-2014·2013-11-20

    Urologix Recalls Prostiva RF Therapy Hand Piece Kits Due to Deployment Force Issue

    Urologix is recalling 142 Prostiva RF Therapy Hand Piece Kits because the hand piece deployment force exceeded maximum specifications.

    Product
    Prostiva RF Therapy Hand Piece Kit, REF 8929, Rx only, sterilized using Ethylene Oxide. The Prostiva RF Model 8929 Hand Piece Kit is the delivery system component of the Prostiva RF Therapy System. Prostiva RF Therapy delivers low-levels of radiofrequency (RF) energy directly…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0192-2014·2013-11-20

    DePuy Mitek FMS Outflow Tubing Recalled Due to Valve Malfunction

    DePuy Mitek is recalling FMS Outflow Tubing because the pillow valve may not perform as intended, potentially leading to backflow of irrigation fluid and patient cross-contamination.

    Product
    DePuy Mitek FMS Outflow Tubing with One-Way valve Product Code:284649 Product Usage: The Intermediary Tubing for FMS¿ Fluid Management Systems connects the Inflow Tubing to the arthroscopic sheath during arthroscopic procedures. The Polyvinyl Chloride (PVC) tubing…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0284-2014·2013-11-20

    Hospira Recalls Plum A+ Infusion Systems Due to Broken Pressure Sensor Pin

    Hospira is recalling 10,669 Plum A+ Infusion Systems because the distal pressure sensor pin may break. This defect can prevent the device from detecting occlusions in the administration set.

    Product
    The Plum A+ Infusion System is a cassette based multifunction infusion system that allows two lines in and one line out and can be used for standard, piggyback, or concurrent delivery. The Plum A+ Infusion System is designed to deliver parenteral, enteral, or epidural infusions…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0275-2014·2013-11-20

    DeRoyal Surgical Eye Spears Recalled for Incorrect X-Ray Detectability Labeling

    DeRoyal Industries is recalling one lot of Surgical Eye Spears because they were labeled as x-ray detectable but contained non-detectable product.

    Product
    DeRoyal (R) Surgical Eye Spears, REF 30-049, Sterile EO, Manufacturer: DeRoyal Industries, Inc. 200 DeBusk Lane, Powell, TN 37849, MADE IN GUATEMALA cleaning of fluids from surgical site in or near the eye
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0282-2014·2013-11-20

    Draeger Ceiling Supply Units Recalled Due to Broken Drive Screw

    Draeger Medical is recalling 139 Movita 603x/DVE 803x Ceiling Supply Units because a broken drive screw caused the lift arm to fall.

    Product
    Draeger Movita 603x/DVE 803x Ceiling Supply Unit. It is intended for use in operating theaters and intensive care
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0270-2014·2013-11-20

    GE Healthcare Recalls AW Workstations Due to Image Orientation Error

    GE Healthcare is recalling AW VolumeShare and AW Server software due to a potential safety issue where images may display in the wrong orientation after rotation.

    Product
    AW VolumeShare 4 (ADVANTAGE WORKSTATION 4.3.), AW VolumeShare 5 (AW VOLUMESHARE 5 WITH ANGIOVIZ OPTION), AW Server. K052995: Advantage Workstation 4.3 is a review station, which allows easy selection, review, processing and filming of multi-modality DICOM images from a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0291-2014·2013-11-20

    Beckman Coulter Recalls Access 2 Immunoassay System Due to Fuse Defect

    Beckman Coulter is recalling the Access 2 Immunoassay System because the fuses may have the wrong amperage.

    Product
    Access 2 Immunoassay System, Part Number: 81600N The Access Immunoassay System is an in vitro diagnostic device used for the quantitative, semi-quantitative or qualitative determination of various analyte concentrations found in human body fluids.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0203-2014·2013-11-20

    Hospira Recalls Plum A+ Hyperbaric Infusion Pumps Due to Calibration Drift

    Hospira is recalling 179 Plum A+ Hyperbaric Infusion Pumps because distal pressure sensor calibration drift may cause false alarms or occlusions.

    Product
    Plum A+ Hyperbaric Infusion Pump; List Number 11005; Labeled in part: PLUM A+ HYPERBARIC; Product Usage: The Plum A+ Infusion Systems are a multipurpose family of devices that provides precise delivery of multiple therapies across the general spectrum of clinical…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0204-2014·2013-11-20

    Infusion pumps are recalled for distal pressure sensor drift

    Hospira recalled 10,669 Plum A+ infusion pumps after reports of distal pressure sensor calibration drift. The issue may cause false occlusion alarms or distal occlusions.

    Product
    Plum A+ Infusion Pump; List Number: 11971; Product Usage: The Plum A+ Infusion Systems are a multipurpose family of devices that provides precise delivery of multiple therapies across the general spectrum of clinical care
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0207-2014·2013-11-20

    Hospira Recalls Plum A+ Infusion Pumps Due to Pressure Sensor Calibration Drift

    Hospira is recalling 182,970 Plum A+ Infusion Pumps because pressure sensor calibration drift may cause false alarms or missed occlusions.

    Product
    Plum A+ Infusion Pump; List Number: 12391; Product Usage: The Plum A+ Infusion Systems are a multipurpose family of devices that provides precise delivery of multiple therapies across the general spectrum of clinical care
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0290-2014·2013-11-20

    Hospira Recalls Plum A+ Infusion Systems Due to Broken Sensor Pin Risk

    Hospira Inc. is recalling Plum A+ Infusion Systems because the distal pressure sensor pin may break, potentially preventing the detection of line occlusions.

    Product
    The Plum A+ Infusion System is a cassette based multifunction infusion system that allows two lines in and one line out and can be used for standard, piggyback, or concurrent delivery. The Plum A+ Infusion System is designed to deliver parenteral, enteral, or epidural infusions…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0289-2014·2013-11-20

    Hospira Recalls Plum A+3 Infusion Systems Due to Broken Sensor Pin Risk

    Hospira is recalling 21,551 Plum A+3 Infusion Systems because a distal pressure sensor pin may break, potentially preventing the detection of line occlusions.

    Product
    The Plum A+3 Infusion System is a cassette based multifunction infusion system that allows two lines in and one line out and can be used for standard, piggyback, or concurrent delivery. The Plum A+3 Infusion System is designed to deliver parenteral, enteral, or epidural…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0206-2014·2013-11-20

    Hospira Recalls Plum A+3 Infusion Pumps Due to Pressure Sensor Drift

    Hospira is recalling 214 Plum A+3 Infusion Pump Systems because distal pressure sensor calibration drift may cause false alarms or occlusions.

    Product
    Plum A+3 Infusion Pump System; List Number: 12348; Product Usage: The Plum A+ Infusion Systems are a multipurpose family of devices that provides precise delivery of multiple therapies across the general spectrum of clinical care
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0286-2014·2013-11-20

    Hospira Recalls Plum A+3 Infusion Systems Due to Broken Pressure Sensor Pin

    Hospira is recalling 214 Plum A+3 Infusion Systems because a pressure sensor pin may break, potentially preventing the detection of line occlusions.

    Product
    The Plum A+3 Infusion System is a cassette based multifunction infusion system that allows two lines in and one line out and can be used for standard, piggyback, or concurrent delivery. The Plum A+3 Infusion System is designed to deliver parenteral, enteral, or epidural…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0197-2014·2013-11-20

    Baxter Recalls SIGMA SPECTRUM Infusion Pumps Due to Alarm Issues

    Baxter Healthcare is recalling SIGMA SPECTRUM Infusion Pumps because they may trigger false upstream occlusion or air-in-line alarms during use.

    Product
    SIGMA SPECTRUM Infusion Pump with Master Drug Library. Intended to be used for the controlled administration of intravenous fluids.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0208-2014·2013-11-20

    Hospira Recalls Plum A+ Infusion Pumps Due to Pressure Sensor Drift

    Hospira is recalling 7,691 Plum A+ Infusion Pumps because pressure sensor calibration drift may cause false alarms or undetected occlusions.

    Product
    Plum A+ Infusion Pump; List Number: 12618; Product Usage: The Plum A+ Infusion Systems are a multipurpose family of devices that provides precise delivery of multiple therapies across the general spectrum of clinical care
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0279-2014·2013-11-20

    Medtronic Activa Neurostimulators Recalled for Loss of Stimulation

    Medtronic is recalling specific Activa rechargeable neurostimulators because they may lose stimulation when switching programs. Therapy can be restored using the Physician Recharge mode.

    Product
    Medtronic Activa PC, model 37601, and Activa RC, model 37612, Activa SC, models 37602 and 37603. Multi-program Rechargeable Neurostimulator for Deep Brain Stimulation.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0195-2014·2013-11-20

    Terumo Recalls Sarns Soft-Flow Aortic Cannulas Due to Particulate

    Terumo is recalling 30 units of Sarns Soft-Flow Aortic Cannulas because loose fiber particulate was found during inspection.

    Product
    Sarns" Soft-Flow¿ Aortic Cannula without Suture Flange, straight tip, wire-reinforced with luer port, aortic cannula, 8.0 mm (24 Fr) OD with 3/8" connector, 14" (36 cm) long. Indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery.
    Category
    Medical Device
    Distribution
    9 states
  • HighFDA (Devices)·Z-0285-2014·2013-11-20

    Hospira Recalls Plum A+ Infusion Systems Due to Broken Sensor Pin Risk

    Hospira is recalling 71 Plum A+ Infusion Systems because a pressure sensor pin may break, potentially preventing the detection of line occlusions.

    Product
    The Plum A+ Infusion System is a cassette based multifunction infusion system that allows two lines in and one line out and can be used for standard, piggyback, or concurrent delivery. The Plum A+ Infusion System is designed to deliver parenteral, enteral, or epidural infusions…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0269-2014·2013-11-20

    Philips IntelliSpace PACS 4.4 Software Recall for Image Storage Defect

    Philips is recalling IntelliSpace PACS 4.4 software due to a timing issue that may prevent the system from storing additional images, potentially affecting clinical diagnoses.

    Product
    Philips brand IntelliSpace PACS 4.4, Image Management System; The system is a software package used with general purpose computing hardware to acquire, store, distribute, process and display images and associated data throughout a clinical environment. Product is manufactured…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0191-2014·2013-11-20

    DePuy Mitek FMS Intermediary Tubing Recalled Due to Valve Malfunction

    DePuy Mitek is recalling FMS Intermediary Tubing with One-Way Valve because the pillow valve may not perform as intended, potentially leading to patient cross-contamination.

    Product
    DePuy Mitek FMS Intermediary Tubing with One-Way valve Product Code: 281142 Product Usage: The Intermediary Tubing for FMS¿ Fluid Management Systems connects the Inflow Tubing to the arthroscopic sheath during arthroscopic procedures. The Polyvinyl Chloride (PVC) tubing…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0283-2014·2013-11-20

    Hospira Recalls Plum A+ Infusers Due to Broken Pressure Sensor Pin

    Hospira Inc. is recalling 179 Plum A+ Hyperbaric Infusion Systems because the distal pressure sensor pin may break, potentially preventing the detection of line occlusions.

    Product
    The Plum A+ Hyperbaric Infusion System is a cassette based multifunction infusion system that allows two lines in and one line out and can be used for standard, piggyback, or concurrent delivery. The Plum A+ Hyperbaric Infusion System is designed to deliver parenteral, enteral…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0287-2014·2013-11-20

    Hospira Recalls Plum A+ Infusion Systems Due to Broken Sensor Pin Risk

    Hospira Inc. is recalling 182,971 Plum A+ Infusion Systems because a distal pressure sensor pin may break, potentially preventing the detection of line occlusions.

    Product
    The Plum A+ Infusion System is a cassette based multifunction infusion system that allows two lines in and one line out and can be used for standard, piggyback, or concurrent delivery. The Plum A+ Infusion System is designed to deliver parenteral, enteral, or epidural infusions…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0288-2014·2013-11-20

    Hospira Recalls Plum A+3 Infusion Systems Due to Broken Sensor Pin Risk

    Hospira is recalling 7,692 Plum A+3 Infusion Systems because a pressure sensor pin may break, potentially preventing the detection of line occlusions.

    Product
    The Plum A+3 Infusion System is a cassette based multifunction infusion system that allows two lines in and one line out and can be used for standard, piggyback, or concurrent delivery. The Plum A+3 Infusion System is designed to deliver parenteral, enteral, or epidural…
    Category
    Medical Device
    Distribution
    Distributed nationwide