The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

4051–4075 of 7527

  • SevereNHTSA·17V427000·2017-07-06

    Ford Recalls 2017 Edge, Fusion, and Lincoln MKZ for Torque Converter Defect

    Ford is recalling 2017 Edge, Fusion, and Lincoln MKZ vehicles with 2.0L engines and six-speed automatics because torque converter weld studs may be inadequate, risking loss of vehicle movement.

    Product
    FORD — FORD, LINCOLN EDGE, MKZ, FUSION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17E033000·2017-07-05

    Cummins Recalls L9 Diesel Engines in Pierce Fire Trucks

    Cummins is recalling L9 heavy-duty diesel engines installed in Pierce fire trucks because improperly tightened capscrews may cause the flexplate to separate, potentially leading to engine stalling and a crash.

    Product
    ENGINE recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V424000·2017-06-30

    Acura Recalls 2017 MDX Sport Hybrid for Fuel Hose Misrouting

    Honda is recalling 2017 Acura MDX Sport Hybrid vehicles because fuel hoses may be misrouted, potentially causing a fuel leak and fire risk.

    Product
    ACURA — ACURA MDX SPORT HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V415000·2017-06-29

    Lexus Recalls 2017 ES350 Vehicles Due to Steering Tie Rod Defect

    Toyota is recalling 2017 Lexus ES350 vehicles because the right-hand tie rod lock nut may loosen, potentially causing loss of steering and increasing crash risk.

    Product
    LEXUS — LEXUS ES350
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V413000·2017-06-29

    Newmar Recalls 2018 Motorhomes Due to Fuel Pump Drive Gear Slip Risk

    Newmar is recalling 2018 London Aire, King Aire, and Essex motorhomes because a fuel pump drive gear could slip, causing an engine stall and increasing crash risk.

    Product
    NEWMAR — NEWMAR LONDON AIRE, KING AIRE, ESSEX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V412000·2017-06-29

    GM Recalls 2016-2017 Buick Envision for Headliner Safety Defect

    General Motors is recalling 2016-2017 Buick Envision vehicles because replacement headliners may lack required impact-absorbing foam, increasing injury risk in crashes.

    Product
    BUICK — BUICK ENVISION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V429000·2017-06-29

    Mazda Recalls Vehicles Due to Passenger Air Bag Inflator Rupture Risk

    Mazda is recalling 2007-2011 CX-7, CX-9, and 2009-2011 Mazda6 vehicles because the passenger air bag inflators may rupture in a crash, potentially causing serious injury or death.

    Product
    MAZDA — MAZDA CX-7, CX-9, MAZDA6
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V417000·2017-06-29

    Honda Recalls 2007-2011 CR-V Vehicles for Air Bag Inflator Defect

    Honda is recalling 2007-2011 CR-V vehicles where the passenger air bag inflator may have an incorrect wire harness, potentially preventing deployment in a crash.

    Product
    HONDA — HONDA CR-V
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V410000·2017-06-28

    Lakota Colt Trailers Recalled Due to Furnace Venting Defect

    Lakota Corporation is recalling 2018 Colt trailers because the furnace flue may be improperly installed, preventing proper venting. This defect can cause carbon monoxide buildup inside the trailer, posing a risk of injury or death.

    Product
    LAKOTA — LAKOTA COLT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V403000·2017-06-27

    Spartan Recalls 2017-2018 Chassis Due to Fuel Pump Gear Slip Risk

    Spartan Motors is recalling 2017-2018 K3, K4, and Gladiator chassis because a fuel pump gear may slip, causing engine stalls that increase crash risk.

    Product
    SPARTAN — SPARTAN K3, GLADIATOR, K4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V402000·2017-06-26

    Freightliner Trucks Recalled for Missing Check Valve in Brake System

    Daimler Trucks North America is recalling 2015-2017 Freightliner models because a missing check valve could cause sudden parking brake application and increase crash risk.

    Product
    FREIGHTLINER — FREIGHTLINER 114SD, BUSINESS CLASS M2, 108SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V398000·2017-06-26

    Ford Recalls 2016 Escape Vehicles Due to Knee Airbag Defect

    Ford is recalling 2016 Escape vehicles because the driver's knee airbag may not inflate properly in a crash, increasing injury risk.

    Product
    FORD — FORD ESCAPE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V401000·2017-06-26

    Ford Recalls 2017 Explorer Police Interceptor for Missing Seat Attachments

    Ford is recalling 2017 Explorer Police Interceptor vehicles because second-row seats may lack front inboard attachments, failing federal safety standards and increasing crash injury risk.

    Product
    FORD — FORD EXPLORER POLICE INTERCEPT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V399000·2017-06-26

    Trans Tech Transit Buses Recalled for Air Conditioner Fire Risk

    Transportation Collaborative is recalling 2012-2017 Trans Tech buses because a fuse in the air conditioning system may short, overheat, and cause a fire.

    Product
    TRANS TECH — TRANS TECH ST AERO, CST, SST, HORIZON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V397000·2017-06-23

    Honda Recalls 2018 Odyssey Vehicles Due to Seat Belt Latch Defect

    Honda is recalling 2018 Odyssey vehicles because the third-row center seat belt tongue may not latch securely, increasing injury risk in a crash.

    Product
    HONDA — HONDA ODYSSEY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V391000·2017-06-21

    Aston Martin Recalls V8 Vantage for Transmission Fluid Leak Risk

    Aston Martin is recalling 2011-2014 V8 Vantage vehicles because a broken clutch fluid line connector may cause hydraulic leaks, preventing gear shifting or causing the vehicle to roll away.

    Product
    ASTON MARTIN — ASTON MARTIN V8 VANTAGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V390000·2017-06-21

    Aston Martin Recalls 2012 V8 Vantage for Transmission Fluid Leak Risk

    Aston Martin is recalling 2012 V8 Vantage vehicles because a transmission connector may break, causing a fluid leak that could prevent shifting or cause the vehicle to roll away.

    Product
    ASTON MARTIN — ASTON MARTIN V8 VANTAGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V388000·2017-06-20

    KTM Recalls 2016-2017 690 Duke Motorcycles for Fuel Leak Risk

    KTM is recalling 2016-2017 690 Duke motorcycles because the fuel tank filler cap area may leak, increasing the risk of fire or injury.

    Product
    KTM — KTM 690 DUKE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17E029000·2017-06-20

    Cummins Recalls X15 Diesel Engines Due to Fuel Pump Gear Slip

    Cummins is recalling X15 heavy-duty diesel engines because a fuel pump drive gear may slip, causing engine stalls and increasing crash risk.

    Product
    FUEL SYSTEM, DIESEL recall
    Category
    Vehicle
    Distribution
    Distributed nationwide