The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

23501–23525 of 27663

  • HighFDA (Devices)·Z-1542-2015·2015-05-06

    Spacelabs Ultraview SL Command Modules Recalled for Monitoring Suspension

    Spacelabs is recalling Ultraview SL Command Modules upgraded with the Masimo SpO2 Option because monitoring suspends for approximately 10 seconds during resets.

    Product
    Ultraview SL Command Modules, Model 91496-M, upgraded with the Masimo SpO2 Option. Product Usage: The Spacelabs Multi-parameter Module is intended for use with the Patient Care Management System (PCMS) to acquire, monitor, and process various clinical parameters from an…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1520-2015·2015-05-06

    AmTryke Model 1424 Hand Cycle Recalled for Cracked Frames

    Amtryke LLC is recalling 53 Model 1424 Community Cruiser Hand Cycles due to complaints of cracked frames. The recall covers units distributed nationwide to 18 states.

    Product
    AmTryke Model 1424 Community Cruiser Hand Cycle. Therapeutic tricycle.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1552-2015·2015-05-06

    Fresenius 2008K2 Hemodialysis Machines Recalled for Acetate Display Error

    Fresenius Medical Care is recalling 2008K2 hemodialysis machines because the GranuFlo acetate value is incorrectly displayed as 4mEq/l instead of 8mEq/l on the Select Concentrate screen.

    Product
    2008 Series Hemodialysis Machines: 2008K2 with the following product code and description: 190633 2008K2 HEMO SYSTEM, OPTIONAL MODULE; 190618 2008K2 HEMODIALYSIS SYS OLC/DP, SPANISH; 190610 2008K2 HEMODIALYSIS SYS. OLC/DIASAFE PLS; 190630 2008K2 MACHINE, SHORT CAB, OLC/DP, HP…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1462-2015·2015-04-29

    Laax Recalls TIGERPAW System II Implantable Occlusion Fasteners

    Laax, Inc. is recalling TIGERPAW System II implantable fasteners due to reports of tissue tearing and bleeding during use.

    Product
    TIGERPAW System II, Part number C-TP-1509 (9 connector) The TigerPaw System II is an implantable occlusion Fastener to be placed on the Ostium of the Left Atrial Appendage (LAA).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1498-2015·2015-04-29

    Wright Medical Recalls Crosscheck Plating System Due to Specification Defects

    Wright Medical Technology is recalling 100 units of Crosscheck Plating Systems because dimensional specifications are out of tolerance, posing a risk of intraoperative malfunction.

    Product
    CROSSCHECK(R) Plating system, Utility Plate, 6-Hole, REF CCP-UTN6. Orthopedic use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1456-2015·2015-04-29

    OriGen VV13F Reinforced Dual Lumen Catheter Recalled for Separation Risk

    OriGen Biomedical is recalling 51 units of VV13F Reinforced Dual Lumen Catheters because the extension tube may separate from the hub, posing a risk of blood loss.

    Product
    OriGen BIOMEDICAL VV13F Reinforced Dual Lumen Catheter STERILE DISPOSABLE: DO NOT RE-USE Manufactured by: OriGen Biomedical. OriGene VV13F Reinforced Dual Lumen Catheter indicated for use as a single cannula for both venous drainage and re-infusion of blood in the internal…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1461-2015·2015-04-29

    Laax TigerPaw System II Implantable Occlusion Fastener Recalled for Tissue Tearing

    Laax, Inc. is recalling the TigerPaw System II implantable occlusion fastener due to field reports of possible tissue tearing and bleeding during use.

    Product
    TIGERPAW System II, Part number C-TP-1507 (7 connector) The TigerPaw System II is an implantable occlusion Fastener to be placed on the Ostium of the Left Atrial Appendage (LAA).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1513-2015·2015-04-29

    CSA Medical truFreeze Console Cryosurgical Unit Recalled for Excess Liquid Nitrogen Delivery

    CSA Medical is recalling 82 truFreeze Console cryosurgical units because they may deliver excessive liquid nitrogen, posing risks of stricture, scarring, bradycardia, or pneumothorax.

    Product
    CSA Medical truFreeze Console- Cryosurgical Unit Cryogenic Surgical Device Model: CC3-01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1492-2015·2015-04-29

    Wright Medical Recalls Crosscheck Plating System Due to Spec Deviations

    Wright Medical Technology is recalling 270 units of the Crosscheck Plating System because specific dimensions are out of specification, posing a risk of intraoperative malfunction.

    Product
    CROSSCHECK(R) Plating system, MTP CX Plate, Left, REF CCP-MPX1L. Orthopedic use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1457-2015·2015-04-29

    Siemens ADVIA Chemistry Lipase Reagent Recalled for Carryover Contamination

    Siemens Healthcare Diagnostics is recalling ADVIA Chemistry Lipase Reagent because carryover from other reagents can cause falsely elevated test results.

    Product
    ADVIA Chemistry Lipase Reagent , Catalog Number B01-4840-01 REF: 01984894.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1494-2015·2015-04-29

    Wright Medical Recalls Crosscheck Plating System Due to Specification Defects

    Wright Medical Technology is recalling 233 units of the Crosscheck Plating System because dimensional specifications are out of tolerance, posing a risk of intraoperative malfunction.

    Product
    CROSSCHECK(R) Plating system, Utility Plate, 2-Hole, REF CCP-UTN2. Orthopedic use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1472-2015·2015-04-29

    Churchill Medical Systems Recalls 8 Inch Standard Bore Extension Sets

    Churchill Medical Systems is recalling 8-inch Standard Bore Extension Sets due to a potential leak caused by insufficient bonding between the needleless device and the female luer.

    Product
    8" Standard Bore Ext Set, Product Code: BN-481 Accessory device used to administer medical fluids
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1474-2015·2015-04-29

    Churchill Medical Systems Recalls 7-Inch High Pressure Extension Sets

    Churchill Medical Systems is recalling 6,850 units of 7-inch Standard Bore High Pressure Extension Sets due to a potential leak caused by insufficient bonding between the needleless device and female luer.

    Product
    7" Standard Bore High Pressure Ext Set, Product Code: CMS-809 Accessory device used to administer medical fluids
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1471-2015·2015-04-29

    Churchill Medical 4-inch Microbore T-Port Set Recalled for Leaking Risk

    Churchill Medical Systems is recalling 450 units of 4-inch Microbore T-Port Sets due to a potential leak caused by insufficient bonding between components.

    Product
    4" Microbore T-Port Set, Product Code: BN-448 Accessory device used to administer medical fluids
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1495-2015·2015-04-29

    Wright Medical Recalls Crosscheck Plating System Due to Dimensional Defects

    Wright Medical Technology is recalling 308 units of the Crosscheck Plating System because dimensional specifications are out of tolerance, posing a risk of intraoperative malfunction.

    Product
    CROSSCHECK(R) Plating system, Utility Plate, 3-Hole, REF CCP-UTN3. Orthopedic use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1496-2015·2015-04-29

    Wright Medical Recalls Crosscheck Plating System Due to Specification Defects

    Wright Medical Technology is recalling 372 units of the Crosscheck Plating System because dimensional specifications are out of tolerance, posing a risk of intraoperative malfunction.

    Product
    CROSSCHECK(R) Plating system, Utility Plate, 4-Hole, REF CCP-UTN4. Orthopedic use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1480-2015·2015-04-29

    Captiva Lumbar Fusion Reamers Recalled for Detaching Color Rings

    Captiva Spine is recalling 233 lumbar intervertebral fusion system reamers because the titanium color-coded rings may detach.

    Product
    Captiva's lumbar intervertebral fusion system Reamers (color code rings on the Reamers).
    Category
    Medical Device
    Distribution
    7 states
  • HighFDA (Devices)·Z-1475-2015·2015-04-29

    Churchill Medical Systems Recalls 7-inch High Pressure Extension Sets

    Churchill Medical Systems is recalling 6,850 units of 7-inch Standard Bore High Pressure Extension Sets due to a potential leak caused by insufficient bonding.

    Product
    7" Standard Bore High Pressure Ext Set, Product Code: CMS-809 Accessory device used to administer medical fluids
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1485-2015·2015-04-29

    Wright Medical Recalls Crosscheck Plating System Due to Specification Defects

    Wright Medical Technology is recalling 102 units of the Crosscheck Plating System because specific dimensions are out of specification, posing a risk of intraoperative malfunction.

    Product
    CROSSCHECK(R) Plating system, LAPIDUS CX Plate, NEUTRAL, Right, REF CCP-LPX0R. Orthopedic use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1490-2015·2015-04-29

    Wright Medical Recalls Crosscheck Plating System Due to Specification Defects

    Wright Medical Technology is recalling 167 units of the Crosscheck Plating System because dimensional specifications are out of tolerance, posing a risk of intraoperative malfunction.

    Product
    CROSSCHECK(R) Plating system, MTP NX Plate, Left, Recon, REF CCP-MPN2L. Orthopedic use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1517-2015·2015-04-29

    Hospira PCA 3 Infusion Pump Recalled for Door Design Flaw

    Hospira is recalling 8,214 PCA 3 infusion pumps because the clear plastic door design allows excessive flexing, permitting unauthorized access to medication vials.

    Product
    The PCA 3 infusion pump allows clinicians, or patients, to (self) Administer analgesia safely and effectively within clinician programmed limits.
    Category
    Medical Device
    Distribution
    53 states
  • HighFDA (Devices)·Z-1497-2015·2015-04-29

    Wright Medical Crosscheck Plating System Recalled for Dimensional Defects

    Wright Medical Technology is recalling 138 units of the Crosscheck Plating System because dimensional specifications are out of tolerance, posing a risk of intraoperative malfunction.

    Product
    CROSSCHECK(R) Plating system, Utility Plate, 5-Hole, REF CCP-UTN5. Orthopedic use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1464-2015·2015-04-29

    DiaSorin Recalls PRO-Trac II Tacrolimus ELISA Kits Due to Instability

    DiaSorin is recalling 451 PRO-Trac II Tacrolimus ELISA kits because instability may cause falsely elevated patient results.

    Product
    DiaSorin, PRO-Trac II Tacrolimus ELISA kit, REF 32400 and 32400-CN. Product Usage: The PRO-Trac II Tacrolimus ELISA kit is an in vitro reagent system intended for the quantitative determination of tacrolimus (Prografl, FK506) and some metabolites in human EDT A or heparinized…
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1488-2015·2015-04-29

    Wright Medical Recalls Crosscheck Plating System Due to Dimensional Defects

    Wright Medical Technology is recalling 148 units of the Crosscheck Plating system because specific dimensions are out of specification, posing a risk of intraoperative malfunction.

    Product
    CROSSCHECK(R) Plating system, LAPIDUS CX Plate, 2mm Step, Left, REF CCP-LPX2L. Orthopedic use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1515-2015·2015-04-29

    Abbott OptiMedica Catalys Precision Laser System Recalled for Corneal Scoring Risk

    Abbott Medical Optics is recalling 202 OptiMedica Catalys Precision Laser Systems because loss of suction during cataract surgery may cause corneal scoring.

    Product
    OptiMedica Catalys Precision Laser System; Model No(s). Catalys-U (US), and Catalys-I (Outside US). Product Usage: Indicated for use in patients undergoing cataract surgery for removal of crystalline lens.
    Category
    Medical Device
    Distribution
    Distributed nationwide