The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

476–500 of 27681

  • HighFDA (Devices)·Z-2767-2026·2026-07-29

    3mensio Workstation Software Recalled Due to Inaccurate Cardiovascular Measurements

    PIE Medical Imaging B.V. is recalling 3mensio Workstation (Vascular Fenestrated) software because it may provide inaccurate cardiovascular measurements under specific conditions.

    Product
    3mensio Workstation (Vascular Fenestrated) software
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2753-2026·2026-07-29

    Boston Scientific Recalls FARASTAR Ablation Generators Due to Catheter Incompatibility

    Boston Scientific is replacing specific FARASTAR PFA generators that are not compatible with the FARAPOINT PFA catheter. The FDA Class II recall affects 6 units distributed internationally.

    Product
    FARASTAR Ablation Generator EU, Pulsed Field Ablation Generator, Product ID 61M401; Percutaneous Cardiac Ablation Catheter
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2754-2026·2026-07-29

    FARADRIVE Steerable Sheath Clear IDE Recall for Air Embolism Risk

    Boston Scientific recalls 400 units of a cardiac catheter sheath due to potential air embolism risk from valve damage during preparation.

    Product
    FARADRIVE Steerable Sheath Clear IDE, used to facilitate access to the vasculature and into the chambers of the heart, Material Number 21C602, IFU Reference Number 51636751-01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2784-2026·2026-07-29

    Medline Convenience Kits Containing Bard Silastic Foley Catheters Recalled Due to Surface Material Issues

    Medline Industries, LP is recalling 980 Medline convenience kits containing Bard Silastic Foley Catheters because excess raw material on the catheter surface may be harmful.

    Product
    Medline convenience kits containing Bard¿ Silastic¿ Foley Catheters (French sizes 16, 18, 20) 5cc balloons. ROBOTIC CDS980523M
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2788-2026·2026-07-29

    Medline Medical Convenience Kits Recalled Due to Potential Bacillus Contamination

    Medline Industries, LP is recalling specific Medline medical convenience kits because they may contain BD PurPrep 26 mL contaminated with low levels of Bacillus species.

    Product
    Medline medical convenience kits labeled as: 1) KIT PEDIATRIC OPEN HEART MOSES, Medline Kit SKU DYNJ910103B; 2) BASIC HEART CDS, Medline Kit SKU DYNJ910961A.
    Category
    Medical Device
    Distribution
    10 states
  • SevereFDA (Devices)·Z-2678-2026·2026-07-22

    Abiomed Impella Introducer Kit Recalled Due to Potential Leakage

    Oscor Inc. is recalling Abiomed REF: 0052-3025 Introducer Kits for Impella heart pump due to potential leakage from the sidearm and hub region. Manufacturing issues may cause the 14Fr and 23Fr introducer sheaths to leak under the sheath cap and along hub score lines.

    Product
    Abiomed REF: 0052-3025, Introducer Kit for Impella Hemostatic Peel Away Introducer System with Infusion Sideport, 14F 13cm and 25cm. heart pump and accessories.
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-2693-2026·2026-07-22

    ABIOMED Intro Kit Heart Pump Introducer Sheath Leakage Risk

    Abiomed, Inc. is recalling ABIOMED Intro Kit heart pump introducer sheaths due to potential leakage from under the sheath cap and along hub score lines. The manufacturing defects are not visually detectable by users.

    Product
    ABIOMED Intro Kit, 14Fr x 13 and 25 cm, PKGD, JP, Pump Set Code 0052-0023-JP; containing Introducer Product Code 0052-3025-JP. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2686-2026·2026-07-22

    ABIOMED Impella CP Introducer Kit 14 Fr potentially defective sheath

    Abiomed, Inc. is recalling ABIOMED Impella CP Introducer Kit 14 Fr units worldwide due to potential introducer sheath leakage from under the sheath cap and along hub score lines. The manufacturing defect is not visually detectable.

    Product
    ABIOMED Impella CP Introducer Kit 14 Fr, 25 cm, Pump Set Code 0052-0039, containing Kit, 14Fr Introducer, 25cm, Long Taper, Introducer Product Code 0052-3053. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2682-2026·2026-07-22

    ABIOMED Impella CP Heart Pump Introducer Sheath Leakage Risk

    Abiomed is recalling the Impella CP heart pump set (87,277 units worldwide) due to potential leakage from the introducer sheath that cannot be visually detected by users. The defect affects the 14Fr and 23Fr introducers included in every pump set.

    Product
    ABIOMED Impella CP Set, Pump Set Code 0048-0003, containing BIOMED Impella Introducer, 14 Fr, 13 cm & 25 cm, Product Code 0052-3046. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2680-2026·2026-07-22

    Abiomed Impella Introducer Kit recalled for potential fluid leakage

    Oscor Inc. is recalling the Abiomed Impella Hemostatic Peel Away Introducer System (23F) due to manufacturing defects that may cause leakage from the sidearm, under the sheath cap, or along the hub region.

    Product
    Abiomed REF: 0052-3006, Introducer Kit for Impella Hemostatic Peel Away Introducer System with Infusion Sideport, 23F. heart pump and accessories.
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-2683-2026·2026-07-22

    ABIOMED Impella CP Introducer Kit 14Fr heart pump safety recall

    ABIOMED Impella CP Introducer Kit 14Fr is being recalled due to a potential for introducer sheath leakage from under the sheath cap and along hub score lines. The manufacturing defect is not visually detectable by users.

    Product
    ABIOMED Impella CP Introducer Kit 14 Fr, 13 and 25 cm, Pump Set Code 1000550, containing Kit, 14Fr Introducer, 13cm&25cm, Sterile, Introducer Product Code 0052-3046. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2707-2026·2026-07-22

    T-Lok Bone Marrow Tray Kits Recalled for Sterility Testing Failure

    Argon Medical Devices is recalling T-Lok Bone Marrow Tray kits containing Lidocaine HCL Injection USP 1% because the kits did not meet sterility release criteria.

    Product
    T-Lok Bone Marrow Tray, REF: BMT1104STL; BMET1104TL; BMT1104CATL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2691-2026·2026-07-22

    ABIOMED Impella CP Heart Pump Set Introducer Sheath Leakage Risk

    ABIOMED Impella CP heart pump sets contain introducers that may leak from under the sheath cap and along hub score lines. These manufacturing defects are not visible during use.

    Product
    ABIOMED Impella CP Set, Pump Set Code 0048-0044; containing Introducer Product Code 0052-3046. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2684-2026·2026-07-22

    ABIOMED Introducer Kit 23 Fr heart pump accessory leakage risk

    Abiomed is recalling ABIOMED Introducer Kit 23 Fr due to potential sheath leakage from manufacturing defects. The leakage risk is not visually detectable and affects all current batches worldwide.

    Product
    ABIOMED Introducer Kit 23 Fr, 11 cm, Pump Set Code 1000441, containing Kit, 23Fr Introducer, 11cm, Sterile, Introducer Product Code 2000342. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2689-2026·2026-07-22

    ABIOMED Impella CP Heart Pump Set Introducer Sheath Leakage Risk

    ABIOMED is recalling Impella CP heart pump sets worldwide due to a potential for introducer sheath leakage from under the sheath cap and along hub score lines in 14Fr and 23Fr introducers. The manufacturing defect is not visually detectable.

    Product
    ABIOMED Impella CP Set, Pump Set Code 0048-0014; containing Introducer Product Code 0052-3046. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2679-2026·2026-07-22

    Abiomed Introducer Kit for Impella Heart Pump Sheath Leak Risk

    Oscor Inc. is recalling Abiomed introducer kits due to manufacturing issues that may cause the 14Fr and 23Fr introducer sheaths to leak. The recall affects approximately 1,332 units distributed in Massachusetts.

    Product
    Abiomed REF: 0052-3021, Introducer Kit for Impella Hemostatic Peel Away Introducer System with Infusion Sideport, 14F, 23F. heart pump and accessories.
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-2690-2026·2026-07-22

    Abiomed Impella CP Smart Assist Set Heart Pump Introducer Sheath Leakage

    Abiomed is recalling the Impella CP Smart Assist Set due to a potential for introducer sheath leakage from under the sheath cap and along hub score lines in 14Fr and 23Fr introducers. These manufacturing issues are not visually detectable.

    Product
    ABIOMED Impella CP Smart Assist Set, JP, Pump Set Code 0048-0024-JP; containing Introducer Product Code 0052-3025-JP. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2708-2026·2026-07-22

    Arterial Line Kit with Lidocaine HCL Injection Fails Sterility Testing

    Argon Medical Devices is recalling an Arterial Line Kit containing Lidocaine HCL Injection USP because the kits do not meet sterility release criteria, creating a risk of infection from non-sterile medical injection.

    Product
    Arterial Line Kit 20ga x 6, REF: 400115A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2704-2026·2026-07-22

    Transvenous Pacing Electrode Tray with Bipolar Balloon Pacing Electrode Recalled

    Argon Medical Devices is recalling Transvenous Pacing Electrode Trays with Bipolar Balloon Pacing Electrode 5F because kits containing Lidocaine HCL Injection USP did not meet sterility release criteria.

    Product
    Transvenous Pacing Electrode Tray w/ Bipolar Balloon Pacing Electrode 5F, REF: 008416A, 008566A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2720-2026·2026-07-22

    Olympus Ellik Evacuator Recalled for Inadequate Sterilization Risk

    Olympus Corporation of the Americas is recalling the Olympus Ellik Evacuator (Model 194) worldwide because certain sterilization parameters in the instructions may not render the device adequately sterile.

    Product
    Olympus Ellik Evacuator Includes Glass Body, Male Connecting Tubing & Latex Bulb. Model Number: 194.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2724-2026·2026-07-22

    ICU Medical Plum Solo Precision IV Pump May Deliver Excess Medication

    ICU Medical is recalling the Plum Solo Precision IV Pump (v1.0.3) because in specific scenarios, the pump may fail to decrease the displayed volume and could deliver up to twice the programmed medication amount.

    Product
    ICU Medical Plum Solo Precision IV Pump, v1.0.3, Item Number 400010401; infusion pump
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2685-2026·2026-07-22

    Abiomed Impella CP Introducer Kit heart pump accessory recall

    Abiomed is recalling Impella CP Introducer Kits worldwide due to potential leakage from the introducer sheath that cannot be visually detected by users. The manufacturing defect affects 1,540 units across multiple countries.

    Product
    ABIOMED Impella CP Introducer Kit 14 Fr, 13 cm, Pump Set Code 0052-0038, containing Kit, 14Fr Introducer, 13cm, Long Taper, Introducer Product Code 0052-3052. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2687-2026·2026-07-22

    ABIOMED Impella 5.5 Heart Pump Introducer Sheath Leakage Risk Recall

    Abiomed is recalling the Impella 5.5 Smart Assist Set heart pump due to potential leakage from introducer sheaths. The defect is not visually detectable and affects all affected pump sets worldwide.

    Product
    ABIOMED Impella 5.5 Smart Assist Set, JP, Pump Set Codes 1000211, 1000212; containing Introducer Product Code 0052-3006-JP. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide