The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

40101–40125 of 40356

  • HighFDA (Devices)·Z-2026-2012·2012-07-25

    GE OEC Motorized C-Arm Systems Recalled for Defective Power Supply

    GE OEC Medical Systems is recalling OEC 9800 series motorized C-arm systems because a defective vertical lift column power supply is subject to early life failure.

    Product
    OEC 9800, OEC FluoroTrak 9800 Plus, OEC 9800 Plus, OEC 9800 MD Motorized C-arm System designed to provide fluoroscopic and spot-film imaging of the patient during diagnostic, surgical and interventional procedures. The OEC 9800 is designed to provide fluoroscopic and…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2049-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 8000 Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling 81 Sarns Modular Perfusion System 8000 units worldwide due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 8000 base, 5 pump 100V. he Sarns Modular Perfusion System 8000 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2044-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 8000 Recalled for Air Bubble Detection Malfunctions

    Terumo Cardiovascular Systems is recalling 274 Sarns Modular Perfusion System 8000 units due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 8000 base, 4 pump 115V. The Sarns Modular Perfusion system 8000 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2041-2012·2012-07-25

    Varian Eclipse Treatment Planning System Recall for Radiotherapy Prescription Errors

    Varian is recalling Eclipse Treatment Planning Systems because changing dose prescriptions in certain plans may result in incorrect Monitor Units and dose distributions.

    Product
    Varian brand Varian Eclipse Treatment Planning System for radiotherapy; Model Number: H48; Product is manufactured and distributed by Varian Medical Systems Inc., Palo Alto, CA The Eclipse Treatment Planning System (Eclipse TPS) is used to plan radiotherapy treatments for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2046-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 8000 Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling 461 Sarns Modular Perfusion System 8000 units worldwide due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 8000 base, 4 pump 220/240V. The Sarns Modular Perfusion System 8000 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2036-2012·2012-07-25

    Teleflex Medical Recalls Hudson RCI Concha Therm Neptune Humidifiers

    Teleflex Medical is recalling Hudson RCI Concha Therm Neptune Humidifiers because a speaker failure could prevent audio alarms from sounding, potentially delaying patient treatment.

    Product
    Hudson RCI Concha Therm Neptune Humidifier, Rx Only, Product Usage: Usage: Device that is intended to add moisture to, and sometime to warm, the breathing gases for administration to a patient.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2025-2012·2012-07-25

    GE OEC 9900 Elite C-arm System Recalled for Power Supply Defect

    GE OEC recalled 726 OEC 9900 Elite C-arm systems worldwide due to a defective vertical lift column power supply identified during an FDA inspection.

    Product
    OEC 9900 Elite, OEC 9900 Elite MD Motorized C-arm System, OEC 9900 Elite NAV used as an aid to locate anatomical structures during open or percutaneous surgical procedures. The system is an aid to locate anatomical structures during open or percutaneous surgical procedures.…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2045-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 8000 Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling Sarns Modular Perfusion System 8000 units due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 8000 base, 5 pump 115V. The Sarns Modular Perfusion Systern 8000 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2043-2012·2012-07-25

    Terumo Advanced Perfusion System 1 recalled for air bubble detection malfunctions

    Terumo is recalling 648 Advanced Perfusion System 1 units worldwide due to reported malfunctions in the Air Bubble Detection System, including false alarms and oversensitivity.

    Product
    Terumo Advanced Perfusion System 1. System 1 base 220/240V. The Terumo Advanced Perfusion System I is indicated for use in extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures only When used by a qualified…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2023-2012·2012-07-25

    EKOS MACH4 Endovascular Device Recalled for Catheter Marker Dislodgement

    EKOS Corporation is recalling EkoSonic MACH4 Endovascular Devices because radio-opaque marker bands may dislodge and the MicroSonic Device may break during use.

    Product
    EkoSonic MACH4 Endovascular Device (Catalog #500-55106, 500-55112; 500-55118; 500-55124; 500-55130; 500-55140; 500-55150; 500-54106; 500-56130; 500-56140; 500-56150) is a catheter, continuous infusion. it consists of the Intelligent Drug Delivery Catheter (IDDC) and the…
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-2052-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 9000 Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling 31 Sarns Modular Perfusion System 9000 units worldwide due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 9000, 100V with color screen. The Sarns Perfusion System 9000 is indicated for use as a heart-lung system for pumping blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a qualified perfusionist…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2010-2012·2012-07-25

    Terumo Advanced Perfusion System 1 Recalled for Network Communication Failures

    Terumo is recalling 648 Advanced Perfusion System 1 units due to reports of communications or power failures in the system network.

    Product
    Terumo Advanced Perfusion System 1 System 1 Base, 220/240V. The Terumo Advanced Perfusion System 1 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2016-2012·2012-07-25

    Stryker Recalls T2 Knee Arthrodesis Nails Due to Sterile Barrier Breach Risk

    Stryker is recalling 532 units of T2 Knee Arthrodesis Nails because of a potential breach in the sterile packaging barrier.

    Product
    Stryker T2 Arthrodesis Nailing System. Manufacturer: Stryker Trauma GmbH, Professor-Kuntscher-Str. 1-5, 24232 Schonkirchen Germany. Distributed in the USA by Stryker Orthopaedics, 325 Corporate Drive, Mahwah, NJ 07430. The T2 Arthrodesis Nail is intended for the treatment…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2035-2012·2012-07-25

    Philips Brilliance CT Scanners Recalled for Defective Carbon Table Top Bolts

    Philips Medical Systems is recalling 524 Brilliance CT scanners because defective bolts securing the carbon table top may break off.

    Product
    Philips Brilliance 6, 16, 40, 64, Big Bore, iCT and iCT SP are Computed Tomography X-Ray Systems. The devices are Computed Tomography Systems that are intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2033-2012·2012-07-25

    Stryker AVS Navigator Trials Recalled for Shaft Failure

    Stryker Spine is recalling AVS Navigator Trials because the shaft may fail at the junction of the trial head.

    Product
    Stryker AVS Navigator Trials 6mm-15mm Manufactured by: Stryker Spine SAS Z.1 Marticot-33610-Cestas -France +33 (0) 5.57.97.06.30 http;//www.stryker.com Distributed in the USA by Stryker Spine 2 Pearl Court. Allendale NJ 07401-1677 USA +1-201-780-8000 Cestas France…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2015-2012·2012-07-25

    GE Healthcare Recalls Invasive Blood Pressure Care Cables

    GE Healthcare is recalling 279 invasive blood pressure care cables due to a faulty O-ring that prevents correct blood pressure monitoring.

    Product
    GE Healthcare, Invasive Blood Pressure Care Cables. Product ID Number: 2016995-001, 2016995-002, 2016995-003, 2016995-004.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2042-2012·2012-07-25

    Terumo Advanced Perfusion System Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling 992 Advanced Perfusion System I units worldwide due to reported malfunctions in the Air Bubble Detection System, including oversensitivity and false alarms.

    Product
    Terumo Advanced Perfusion System 1. System 1 base 100/120V. The Terumo Advanced Perfusion System I is indicated for use in extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures only When used by a qualified…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2047-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 8000 Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling 310 Sarns Modular Perfusion System 8000 units worldwide due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 8000 base, 5 pump 220/240V. The Sarns Modular Perfusion System 8000 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2039-2012·2012-07-25

    Alere Triage Tox+MTD Drug Screen Recalled for Decreased Precision and Accuracy

    Alere San Diego is recalling 9,997 Triage Tox+MTD Drug Screen kits because they may produce false positive or negative results due to decreased precision and accuracy.

    Product
    Alere Triage Tox+MTD Drug Screen, PN 94400 Product Usage: The Alere Triage TOX Drug Screen is a fluorescence immunoassay to be used with the Alere Triage Meters for the qualitative determination of the presence of drug and/or the major metabolites above the threshold…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2018-2012·2012-07-25

    Kimberly-Clark Recalls MicroCool Surgical Gowns Due to Fabric Defects

    Kimberly-Clark is recalling specific lots of MicroCool surgical gowns because they pill, lint, or allow blood to pass through.

    Product
    MicroCool Breathable Impervious Gown with Secure Fit Surgical, (Large and X-Large), Made in Honduras. The Kimberly Clark Micro COOL Surgical Gowns are sterile single use surgical apparel intended to be worn by heathcare professionals to help protect the patient and the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2048-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 8000 Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling 26 Sarns Modular Perfusion System 8000 units due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 8000 base, 4 pump 100V. The Sarns Modular Perfusion System 8000 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2051-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 9000 Recalled for Air Bubble Detection Malfunctions

    Terumo Cardiovascular Systems is recalling 286 Sarns Modular Perfusion System 9000 units worldwide due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 9000, 220/240V with color screen. The Sarns Perfusion System 9000 is indicated for use as a heart-lung system for pumping blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a qualified…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2020-2012·2012-07-25

    Terumo Advanced Perfusion System 1 Recalled for Power Malfunction

    Terumo is recalling 992 Advanced Perfusion System 1 units due to a power loss error message that may affect system stability during medical procedures.

    Product
    System 1 Base, 100/120V. The Terumo Advanced Perfusion System 1 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a qualified medical professional…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2017-2012·2012-07-25

    Kimberly-Clark Recalls MicroCool Surgical Gowns Due to Material Defects

    Kimberly-Clark is recalling specific lots of MicroCool surgical gowns because they pill, lint, or allow blood strikethrough, potentially compromising sterility.

    Product
    MicroCool Breathable Impervious Surgical Gown, (Large and X-Large), Sterile, Made in Honduras. The Kimberly Clark Micro COOL Surgical Gowns are sterile single use surgical apparel intended to be worn by heathcare professionals to help protect the patient and the healthcare…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2050-2012·2012-07-25

    Terumo Sarns Modular Perfusion System 9000 Recalled for Air Bubble Detection Malfunctions

    Terumo is recalling 484 Sarns Modular Perfusion System 9000 units worldwide due to reported malfunctions in the Air Bubble Detection System, including false alarms and over-sensitivity.

    Product
    Sarns Modular Perfusion System 9000, 115V with color screen. The Sarns Perfusion System 9000 is indicated for use as a heart-lung system for pumping blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when used by a qualified perfusionist…
    Category
    Medical Device
    Distribution
    Distributed nationwide