The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

35726–35750 of 40325

  • SevereFDA (Devices)·Z-1639-2014·2014-05-28

    Fresenius Recalls Naturalyte Liquid Bicarbonate Concentrate Due to Contamination

    Fresenius Medical Care is recalling Naturalyte Liquid Bicarbonate Concentrate bottles due to potential contamination. The product is used in hemodialysis machines.

    Product
    Naturalyte Liquid Bicarbonate Concentrate, 6.4 Liter Bottle Part Number: 08-4000-LB The concentrate is formulated to be used with a three steam hemodialysis machine which is calibrated for acid and bicarbonate concentrates
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1643-2014·2014-05-28

    Gambro Polyflux Revaclear Dialyzers Recalled for Internal Blood Leaks

    Gambro Renal Products is recalling Polyflux Revaclear capillary dialyzers due to reports of internal blood leaks.

    Product
    Polyflux Revaclear, Capillary Dialyzer, Model Number 110633; Gambro Renal Products, Inc. Intended for the treatment of acute and chronic renal failure by hemodialysis.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1624-2014·2014-05-28

    Hospira Recalls T-U-R Y-Sets Due to Potential Sterile Package Seal Defect

    Hospira is recalling specific T-U-R Y-Sets because the Tyvek cover may not be completely sealed, potentially compromising the sterile package.

    Product
    LATEX-FREE; T-U-R Y-Set; Nonvented Set for Transurethral Resection Procedures; 96 inch (244 cm); For Flexible Irrigation Container Systems; List No. 6543-01; single use; Hospira Product Usage: For use in transurethral resection procedures
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1626-2014·2014-05-28

    Hospira Recalls Large Bore Y-Irrigation Sets Due to Packaging Seal Defect

    Hospira is recalling specific lots of Large Bore Y-Irrigation Sets because the Tyvek cover may not be completely sealed, potentially compromising the sterile package.

    Product
    LATEX-FREE; LARGE BORE Y-IRRIGATION SET; Nonvented Set; 100 inch (254 cm); For Flexible Irrigation Container Systems; List No. 6599-01; single use; Hospira Product Usage: For Use With Flexible Irrigation Container Systems
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1640-2014·2014-05-28

    GE Healthcare Recalls NeuroMuscular Transmission Modules for Inaccurate Readings

    GE Healthcare is recalling 1,794 NeuroMuscular Transmission Modules because they may display inaccurate muscle relaxation levels when used with ElectroSensors.

    Product
    GE Healthcare, NeuroMuscular Transmission Module, E-NMT-01 Product Usage: The Datex-Ohmeda S/5TM E-NMT module is indicated for monitoring the relaxation of the patient and regional block stimulation for nerve location.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1646-2014·2014-05-28

    Philips XIRIS 8.1.50.0 Recall Due to Patient Data Synchronization Error

    Philips Healthcare Informatics is recalling 5 units of XIRIS 8.1.50.0 due to a synchronization error that may display incorrect patient information.

    Product
    Philips XRE, the dictation editor system included in the Philips XIRIS 8.1.50 XIRIS is a radiology information system (RIS) is a computer system that assist radiology services in the storing, manipulating and retrieving of patient information. This included patient scheduling…
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1635-2014·2014-05-28

    Microline Renew Fenestrated Control Tip Grasper Recalled for Jaw Breakage

    Microline Surgical is recalling 540 units of Renew Fenestrated Control Tip Graspers because the jaw may break when force is applied.

    Product
    Microline Renew Fenestrated Control Tip Grasper, Single Patient Use, Product Number: 3222 The ReNew Fenestrated Grasper Forceps Tips are intended to cut, grasp, and dissect various abdominal tissue for use in endoscopic, including laproscopic surgical procedures where…
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-1650-2014·2014-05-28

    Smiths Medical Recalls Snuggle Warm Sterile Cardiac Warming Blankets

    Smiths Medical ASD, Inc. is recalling 2,120 Snuggle Warm Sterile Cardiac Connective Warming Blankets because the hose could separate from the blanket.

    Product
    SW-2008 Snuggle Warm Sterile Cardiac Connective Warming Blanket; used with the Equator Convective Warmer, are intended for thermal regulation of a patient's temperture and are designed to prevent hypothermia and/ or reduce cold discomfort during and after surgical procedures.
    Category
    Medical Device
    Distribution
    9 states
  • HighFDA (Devices)·Z-1627-2014·2014-05-28

    Hospira Recalls Latex-Free 4-Lead T-U-R Irrigation Sets Due to Sealing Defect

    Hospira Inc. is recalling 29,380 Latex-Free 4-Lead T-U-R Irrigation Sets because the Tyvek cover may not be completely sealed, potentially compromising sterility.

    Product
    LATEX-FREE; 4-LEAD T-U-R IRRIGATION SET; Nonvented Set for Transurethral Resection Procedures; 85 inch (216 cm); For Flexible Irrigation Container Systems; List No. 15239-01; Single Use; Hospira Product Usage: For Transurethral Resection Procedures
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1647-2014·2014-05-28

    Siemens Recalls Dimension Vista Cyclosporine Test Kits Due to Under-Recovery

    Siemens Healthcare Diagnostics is recalling Dimension Vista CSA and CSAE test kits because they may under-recover cyclosporine levels when using Small Sample Containers.

    Product
    Dimension Vista¿ CSA and CSAE The Cyclosporine method is an in vitro diagnostic test for the quantitative measurement of cyclosporine A (CSA) in human whole blood on the Dimension Vista¿ System. Measurements of CSA are used as an aid in the management of heart, liver and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1651-2014·2014-05-28

    Heraeus Kulzer Recalls Gluma Desensitizer Power Gel Due to Extrusion Risk

    Heraeus Kulzer is recalling Gluma Desensitizer Power Gel because it may extrude all at once, causing irritation, burning, or blistering to patients or dental professionals.

    Product
    Gluma Desensitizer Power Gel Product Usage: Usage: This is a class 2 medical device. For reduction or elimination of pain in exposed cervical areas that do not require restoration. It is also used for alleviation or reduction of dentinal sensitivity after preparation of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1649-2014·2014-05-28

    Medline Esmark Elastic Bandages Recalled for Sterilization Failure

    Medline Industries is recalling 2,860 Esmark Elastic Bandages because they may not have been properly sterilized.

    Product
    Esmark Elastic Bandage (Sterile), 4" x 9'. Item DYNJ05116A, Individually wrapped, 20 bandages per case. Packaged by Medline Industries Inc. This product is used as an elastic bandage to support and compress a part of a patient's body. It is also used as a tourniquet to restrict…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1642-2014·2014-05-28

    Fujifilm Recalls 14 MXR-35 X-ray Generators for Missing Certification Labeling

    Fujifilm Medical System USA is recalling 14 MXR-35 Diagnostic X-ray High Voltage Generators because the labeling did not include the certification statement required by 21 CFR Part 10 10.2.

    Product
    MXR-35 Diagnostic X-ray High Voltage Generator manufactured by DRGEM Corporation. x-ray generator
    Category
    Medical Device
    Distribution
    2 states
  • ModerateFDA (Devices)·Z-1648-2014·2014-05-28

    Ortho-Clinical VITROS TT4 Calibrator Recalled for Calibration Failures

    Ortho-Clinical Diagnostics is recalling VITROS TT4 Calibrators due to potential calibration failures or low quality control results.

    Product
    VITROS TT4 Calibrator For the quantitative measurement of total thyroxine (T4) in human serum and plasma (EDTA or heparin) using the VITROS ECi/ECiQ Immunodiagnostic Systems, the VITROS 3600 Immunodiagnostic System and the VITROS 5600 Integrated System to aid in the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1625-2014·2014-05-28

    Hospira Recalls Cystoscopy Sets Due to Potential Sterile Package Seal Defect

    Hospira Inc. is recalling specific cystoscopy and irrigation sets because the Tyvek cover may not be completely sealed, potentially compromising the sterile package.

    Product
    LATEX-FREE; CYSTOSCOPY/IRRIGATION SET; Nonvented, 77 inch (195 cm) for Constant or Intermittent Bladder Irrigation; For Use with Flexible Irrigation Container System; List No. 6544-01; Hospira Product Usage: For Constant or Intermittent Bladder Irrigation
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1633-2014·2014-05-28

    Arrowgard Blue Central Venous Catheter Recalled for Labeling Error

    Arrow International Inc. is recalling Arrowgard Blue and Blue Plus catheters because the packaging incorrectly lists an echogenic needle, which may not be present.

    Product
    Arrowgard Blue and Arrowgard Blue Plus Pressure Injectable Central Venous Catheter, a multiple-lumen catheter that permits venous access to central circulation. Catalog number ASK-45703-PHF.
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-1632-2014·2014-05-28

    SCM True Air Technologies Recalls MaXair Mattress Replacement Systems

    SCM True Air Technologies is recalling 83 MaXair True Low Air Loss Mattress Replacement Systems due to design control and documentation deficiencies.

    Product
    MaXair True Low Air Loss Mattress Replacement System, True Air Technologies, Inc.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1623-2014·2014-05-28

    Hospira Recalls Latex-Free Extension Sets Due to Packaging Seal Defect

    Hospira is recalling specific latex-free extension sets because the Tyvek cover may not be completely sealed, potentially compromising the sterile package.

    Product
    LATEX-FREE; EXTENSION SET; For Bladder Irrigation or Urinary Drainage, Compatible with T-U-R FLOW-POUCH RESERVOIR, list 6542, 71 inch (180 cm) Nominal Length; List No. 4693-01; single use; Hospira Product Usage: Bladder irrigation or urinary drainage
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1622-2014·2014-05-28

    Siemens syngo Imaging XS Software Recall Due to Data Deletion Risk

    Siemens Medical Solutions is recalling 64 syngo Imaging XS systems because a software change may have caused the deletion of archived medical images.

    Product
    syngo Imaging XS Syngo Imaging XS is a Picture Archiving and Communication System (PACS) intended to display, process, read, report, communicate, distribute, store and archive digital medical images. It supports the physician in diagnosis and treatment planning. Syngo Imaging…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1629-2014·2014-05-28

    Anspach Irrigation Clip 40 Recalled Due to Incorrect Assembly

    The Anspach Effort, Inc. is recalling 150 Anspach Irrigation Clip 40 units because they were assembled with incorrect, smaller clips.

    Product
    Anspach Irrigation Clip 40 Product Usage: Irrigation clips provide a method of supplying controlled, cooling irrigation during cutting, shaping, and removal of bone, including bones of the skull and spine.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1631-2014·2014-05-28

    SCM True Air Technologies Recalls ECATS E 850 Bariatric Beds

    SCM True Air Technologies is recalling 48 ECATS E 850 Bariatric Beds due to manufacturing documentation and vendor approval failures.

    Product
    ECATS E 850 Bariatric Bed, True Air Technologies, Inc.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1566-2014·2014-05-21

    Baxter ABACUS TPN Calculation Software Recalled for Calculation Errors

    Baxter Corporation is recalling ABACUS TPN Calculation Software because it may calculate incorrect electrolyte quantities and display inaccurate data.

    Product
    ABACUS TPN Calculation Software, Product Codes: 8300-0045 ABACUS CE (Calculator Edition), 8300-0046 ABACUS SE (Single-Workstation Edition), 8300-0047 ABACUS ME (Multi-Workstation Edition), 8300-0156 ABACUS 3.0 CE, 8300-0157 ABACUS 3.0 SE, 8300-0158 ABACUS 3.0 ME, 8300-0166…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1619-2014·2014-05-21

    Fresenius Hemodialysis Machine Test Boards Recalled for Pump Detection Failure

    Fresenius Medical Care is recalling Revision K Actuator Test Boards for 2008-Series Hemodialysis Machines because they may fail to detect a disconnected Ultrafiltration Pump.

    Product
    Revision K Actuator Test Boards sold as replacement parts for use with Fresenius 2008-Series Hemodialysis Machines (2008K, 2008K2, 2008K@home and 2008T). Part Number: 190713 Revision K
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1567-2014·2014-05-21

    CareFusion Recalls Alaris Pump 8100 Due to Software Delay Issue

    CareFusion is recalling Alaris Pump model 8100 units with specific software versions because a defect may prevent the pump from properly delaying infusions.

    Product
    Alaris Pump model 8100 with software version 9.1.18 and software upgrade kits with "Delay Until" Option and "Multidose" Feature The Alaris Pump module is a large volume infusion pump offered under the Alaris System. The Alaris Pump module will deliver medication and fluids…
    Category
    Medical Device
    Distribution
    Distributed nationwide