The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

34026–34050 of 40325

  • LowFDA (Devices)·Z-0826-2015·2014-12-24

    Teleflex Recalls Weck Hemoclip Ligating Clips Due to Labeling Error

    Teleflex Medical is recalling 3,180 units of Weck Hemoclip Ligating Clips because manufacturing and expiration dates were transposed on the packaging labels.

    Product
    WECK Hemoclip¿ Traditional Medium Tantalum Ligating Clips. Weck Ligating Clips are intended for use in procedures involving vessels or anatomic structures for which the surgeon determines ligating clips are the best choice.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0763-2015·2014-12-24

    Stryker Laparoscopic Needle Nose Forceps Recalled for Sterilization Documentation Error

    Stryker Endoscopy is recalling 180,573 units of laparoscopic needle nose forceps because the instructions for use do not support specific sterilization methods.

    Product
    PKG, 3MM INSERT, NEEDLE NOSE FORCEPS, 20CM, P/N 0250282005 Laparoscopic Manual Instruments are intended for cutting, holding, grasping and manipulating of tissue, organs, organ areas and surgical auxiliaries such as suturing material. Some instruments have radio frequency (RF)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0739-2015·2014-12-24

    Stryker Fundus Grasper Forceps Recalled Due to Sterilization Instructions

    Stryker Endoscopy is recalling Fundus Grasper Forceps because the instructions for use do not support specific sterilization methods.

    Product
    PKG, 5MM, 45CM, INSERT, FUNDUS GRASPER FORCEPS, P/N 0250080735 Laparoscopic Manual Instruments are intended for cutting, holding, grasping and manipulating of tissue, organs, organ areas and surgical auxiliaries such as suturing material. Some instruments have radio frequency…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0666-2015·2014-12-24

    Stryker Endoscopy Recalls Palpation Probes Due to Sterilization Instructions

    Stryker Endoscopy is recalling 180,573 palpation probes because the instructions for use do not support specific sterilization methods.

    Product
    PKG, PALPATION PROBE GRADUATED 5MM 45CM, P/N 0250080136 Laparoscopic Manual Instruments are intended for cutting, holding, grasping and manipulating of tissue, organs, organ areas and surgical auxiliaries such as suturing material. Some instruments have radio frequency (RF)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0804-2015·2014-12-24

    AGFA Healthcare Recalls Radiomat M+ NIF Films Due to Coating Artifacts

    AGFA Healthcare is recalling 142 units of Radiomat M+ NIF films because the coating may show small bright thin lines when processed.

    Product
    Radiomat M+ NIF 14 x 17, Radiomat M+ NIF 35CM x 43CM, Radiomat M+ NIF 10 x 12, Radiomat M+ NIF 25,4CM x 30,5CM
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0180-2015·2014-12-17

    Covidien Recalls Puritan Bennett 980 Ventilators Due to Capacitor Failure

    Nellcor Puritan Bennett is recalling 324 Puritan Bennett 980 Ventilators because a capacitor component can fail, causing a dim screen and thermal odor.

    Product
    Covidien Puritan Bennett 980 Ventilator, Rx ONLY, Made in Ireland., Covidien LLC, USA. REF 980X1ENDIUU.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0507-2015·2014-12-17

    TomoTherapy Treatment System Recalled for Jaw Position Monitoring Failure

    TomoTherapy Incorporated is recalling 210 TomoTherapy Treatment Systems worldwide due to a software defect that may fail to monitor jaw position after an error, potentially leading to incorrect treatment delivery.

    Product
    TomoTherapy Treatment System with software versions 2.0.1 / 2.0.2 / 2.0.3/ (Hi:Art 5.0.1 / 5.0.2 / 5.0.3)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0562-2015·2014-12-17

    PFM Medical Recalls ASEPT Drainage Kits for Bacterial Endotoxin Concerns

    PFM Medical is recalling ASEPT 600 ml Drainage Kits because they may exceed USP limits for bacterial endotoxin. The recall affects 1,470 units distributed in the US and abroad.

    Product
    ASEPT 600 ml Drainage Kit, Ref No. 622287, M7052 Product Usage: The ASEPT Drainage Kit is an accessory to be used to connect to the ASEPT Pleural or Peritoneal Drainage Catheter to drain fluid from the chest or abdomen.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0523-2015·2014-12-17

    Siemens Mammomat Inspiration System Recalled for Potential Instability

    Siemens is recalling three Mammomat Inspiration systems because the workstation table may fall over if not secured, posing a risk of serious injury.

    Product
    Mammomat Inspiration system: Product Usage: mammography exams, screening, diagnosis, and stereotactic biopsies under the supervision of medical professionals. Mammographic images can be interpreted by either hard copy film or soft copy workstation.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0590-2015·2014-12-17

    Smith & Nephew Recalls Legion Knee Prosthesis Due to Undersized Stem Taper

    Smith & Nephew is recalling 45 units of the Legion COCR Constrained Femoral Component because the stem taper is undersized and the gauge point is not deep enough.

    Product
    LEGION(TM) COCR CONSTRAINED FEMORAL COMPONENT, SIZE 5, RIGHT, REF 71426005, QTY 1, Smith & Nephew, knee prosthesis Usage:orthopedic.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0524-2015·2014-12-17

    Medtronic MiniMed Infusion Sets Recalled Due to Tubing Detachment Risk

    Medtronic MiniMed is recalling Silhouette and Sure-T infusion sets because tubing may detach, interrupting insulin delivery without an alarm.

    Product
    Medtronic MiniMed Silhouette and/or MiniMed Sure-T Infusion Sets; Paradigm Silhouette infusion sets: MMT-368, MMT-368600, MMT-371, MMT-373, MMT-377, MMT-377600, MMT378, MMT-378600, MMT-38 1, MMT-381 600, MMT-382, MMT-382600, MMT-383, MMT-383600, MMT384, & MMT384600. Sure-T…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0591-2015·2014-12-17

    Smith & Nephew Recalls Legion Knee Prosthesis Due to Undersized Stem Taper

    Smith & Nephew is recalling 23 units of the Legion COCR Constrained Femoral Component because the stem taper is undersized and the gauge point is not deep enough.

    Product
    LEGION(TM) COCR CONSTRAINED FEMORAL COMPONENT, SIZE 6, LEFT, REF 71426006, QTY 1, Smith & Nephew, knee prosthesis Usage:orthopedic.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0518-2015·2014-12-17

    Biomet Microfixation Recalls Total Temporomandibular Joint Replacement System

    Biomet Microfixation is recalling 42 units of the Total Temporomandibular Joint Replacement System because laser etching on the parts is wider and deeper than validated conditions.

    Product
    Total Temporomandibular Joint Replacement System- 50mm Lft Standard Ti Mandi Reconstruction of the temporomandibular joint
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0576-2015·2014-12-17

    Siemens Medical Solutions Recalls Syngo.plaza PACS Software for Print Size Errors

    Siemens Medical Solutions is recalling 149 units of Syngo.plaza and syngo Imaging XS software because printouts may be in incorrect anatomical size, potentially influencing diagnostic decisions.

    Product
    Syngo.plaza, Syngo.plaza VB10A, and syngo Imaging XS : Product Usage: Syngo.plaza is a Picture Archiving and Communication System (PACS) intended to display, process, read, report, communicate, distribute, store and archive digital medical images.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0572-2015·2014-12-17

    BD Insyte Autoguard Catheter Recall for Potential Body Damage

    Becton Dickinson is recalling BD Insyte Autoguard catheters due to potential damage along the catheter body.

    Product
    BD Insyte Autoguard Catheter An active safety engineered peripheral IV catheter with a retracting needle to reduce accidental needle stick injuries. The safety feature (needle retraction) of this device is activated when the clinician depresses the button located on the…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0566-2015·2014-12-17

    PFM Medical Recalls Thoracentesis and Paracentesis Procedure Trays

    PFM Medical is recalling 75 units of Thoracentesis & Paracentesis Procedure Trays because they may exceed USP limits for bacterial endotoxin.

    Product
    Thoracentesis & Paracentesis Procedure Tray, Ref No. M7553, 850004 Product Usage: Short term percutaneous fluid drainage.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0580-2015·2014-12-17

    Boston Scientific Recalls IntellaMap Orion Mapping Catheters Due to Glue Failure

    Boston Scientific is recalling 184 IntellaMap Orion High Resolution Mapping Catheters because a glue bond on the Deployment Interlock Button may fail.

    Product
    IntellaMap Orion High Resolution Mapping Catheter; Material number: M004RC64S0; Catalog number RC64S; Is indicated for electrophysiological mapping (recording or stimulating only) of the cardiac structures of the heart.
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-0588-2015·2014-12-17

    Mevion S250 Proton Therapy System Recalled for Software Defect

    Mevion Medical Systems is recalling one MEVION S250 proton therapy system in Missouri due to a software defect that may cause incorrect dose delivery.

    Product
    MEVION S250, used for proton radiation therapy.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0575-2015·2014-12-17

    INOmax DSIR Nitric Oxide System Recalled for Monitoring Error

    INO Therapeutics is recalling nine INOmax DSIR Nitric Oxide delivery systems because they may report lower-than-expected NO concentrations.

    Product
    INOMAX DSIR Nitric Oxide delivery system, Model 10007, software version 3.1.0., delivers INOMAX (nitric oxide for inhalation) therapy gas and provides continuous monitoring of inspired O2, NO2, and NO, and comprehensive alarm systems. The primary clinical settings are Neonatal…
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-0564-2015·2014-12-17

    PFM Medical Recalls Dual Lumen CT PICC Catheters for Bacterial Endotoxin

    PFM Medical is recalling 90 units of 6F x 60 cm Dual Lumen CT PICC catheters because they may exceed USP limits for bacterial endotoxin.

    Product
    6F x 60 cm Dual Lumen CT PICC, Ref No. PFM2CT6D Product Usage:The PFM CT PICC catheter is indicated for short or long term peripheral access to the central venous system for intravenous therapy, and power injection of contrast media. For blood sampling, infusions, or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0577-2015·2014-12-17

    Invacare Perfecto 2 V Oxygen Concentrator Recalled for Defective Sieve Beds

    Invacare is recalling 5,963 Perfecto 2 V Oxygen Concentrators because defective sieve beds allow dust to migrate, reducing oxygen concentration.

    Product
    Invacare Perfecto 2 V Oxygen Concentrator The finished device is packaged as a single unit. The service part contains a single pair of sieve beds; one pair of sieve beds is used in a single finished device. Intended to provide supplemental oxygen to patients with…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0582-2015·2014-12-17

    Skeletal Dynamics Recalls Align Radial Stems Due to Fracture Reports

    Skeletal Dynamics is recalling 1,700 Align Radial Stems because a report was received indicating the device fractured.

    Product
    Align Radial Stems, Prosthesis, Elbow, Hemi Replacement of the radial head for degenerative or post-traumatic disabilities presenting pain, crepitation, and decreased motion at the radio-humeral and/or proximal radio-ulnar joint with: Joint destruction and/or subluxation and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0568-2015·2014-12-17

    PFM Medical Recalls ASEPT Drainage Bags Due to Bacterial Endotoxin Concerns

    PFM Medical is recalling ASEPT 2000 ml Drainage Bags because they may exceed USP limits for bacterial endotoxin. The recall affects 370 units distributed in the US and internationally.

    Product
    ASEPT 2000 ml Drainage Bag, Ref No. 622280 Product Usage: The ASEPT Drainage Bag is to be used for peritoneal drainage with the ASEPT Peritoneal Drainage Catheter only.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0560-2015·2014-12-17

    Pfm Medical Recalls Rapid Centesis Catheters Due to Bacterial Endotoxin

    Pfm Medical Inc is recalling Rapid Centesis Catheters because they may exceed USP limits for bacterial endotoxin. The recall affects 480 units distributed in the US and abroad.

    Product
    Rapid Centesis Catheter, 5 Fr x 7 cm Catheter, Ref No. M7513 Product Usage: Short term percutaneous fluid drainage
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0531-2015·2014-12-17

    Medtronic Recalls Affinity Fusion Oxygenators Due to Damaged Heat Exchangers

    Medtronic Perfusion Systems is recalling 168 Affinity Fusion Oxygenators with Carmeda Bioactive Surface due to damaged heat exchangers.

    Product
    The Affinity Fusion Oxygenator with Integrated Arterial Filter and Carmeda Bioactive Surface is a single-use, microporous, hollow-fiber, gas-exchange device with plasma resistant fiber and integrated heat exchanger and arterial filter. The oxygenator is bonded on its primary…
    Category
    Medical Device
    Distribution
    2 states