The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

101–125 of 434

  • ModerateCPSC·22720·2022-02-10

    Ski-Doo 2022 Snowmobiles Recalled Due to Speedometer Crash Hazard

    BRP is recalling approximately 400 Ski-Doo 2022 snowmobiles because the speedometer may display half the vehicle's true speed, creating a crash hazard. Consumers should stop using the recalled snowmobiles and contact a Ski-Doo dealer for free repair.

    Product
    Ski-Doo Snowmobiles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateCPSC·22717·2022-01-13

    Textron E-Z-GO Freedom RXV Personal Transportation Vehicles Recalled Due to Fall Hazards

    Textron Specialized Vehicles is recalling about 280 E-Z-GO Freedom RXV personal transportation vehicles with rear-facing seats because the rear seat structure can fail and tilt unexpectedly, creating a fall and injury hazard. Consumers should stop using the rear-facing seat and contact Textron for a free repair.

    Product
    E-Z-GO Freedom RXV with Rear Facing Seat Personal Transportation Vehicles (PTV)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22052·2022-01-12

    EGL and ACE Youth All-Terrain Vehicles Recalled for Safety Standard Violations

    EGL Motor is recalling about 2,900 EGL and ACE branded youth ATVs (models MADIX 125 and D110) because they fail federal safety standards, allowing children to exceed safe speeds and creating laceration and crash hazards.

    Product
    EGL and ACE Branded Youth All-Terrain Vehicles (ATVs)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22716·2022-01-06

    Polaris Outlaw 110 EFI Youth ATVs Recalled for Fire Hazard

    Polaris is recalling about 1,100 Model Year 2022 Outlaw 110 EFI Youth ATVs because the inner layer of the fuel line can leak, posing a fire hazard. No fires or injuries have been reported.

    Product
    Outlaw 110 EFI Youth All-Terrain Vehicles (ATVs)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22043·2022-01-05

    CRT Motor Youth All-Terrain Vehicles Recalled for Crash Hazard

    CRT Motor is recalling about 100 youth ATVs sold at Motorsports Planet because they do not meet mandatory safety requirements and can exceed maximum speed, increasing crash risk.

    Product
    CRT Motor Youth All-Terrain Vehicles (ATVs)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·22714·2021-12-23

    Polaris RZR and GENERAL Recreational Off-Road Vehicles Steering Wheel Separation Recall

    Polaris is recalling about 8,800 RZR and GENERAL recreational off-road vehicles because the steering wheel can separate, causing loss of control and crash risk. Polaris has received 33 reports of broken or cracked steering wheel spokes, including five rollovers and two injuries.

    Product
    Polaris RZR and GENERAL Recreational Off-Road Vehicles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22032·2021-12-15

    Hisun 250cc Utility Vehicles Recalled for Fire Hazard

    Hisun Motors is recalling about 2,500 Sector 250cc and RK Performance 250cc utility vehicles sold at Rural King stores nationwide from November 2014 through June 2021 because grass can accumulate near the exhaust pipe and pose a fire hazard. The company has received five reports of vehicle fires but no injuries.

    Product
    Hisun 250cc Utility Vehicles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22020·2021-11-18

    Honda Pioneer and Talon Recreational Vehicles Steering Loss Recall

    American Honda is recalling about 1,400 Honda Pioneer 700, Pioneer 1000, and Talon 1000 recreational off-highway vehicles equipped with electric power steering. The vehicles can lose steering function, posing crash and injury hazards.

    Product
    Honda Pioneer and Talon ROVs
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22705·2021-11-04

    Kubota RTV-X1100C Utility Vehicles Floor Mat Interference Recall

    Kubota is recalling about 48,875 RTV-X1100C utility vehicles from model years 2013 through 2021 because floor mats can warp or degrade and interfere with the throttle pedal, creating crash and injury risks.

    Product
    Kubota RTV-X1100C Model Utility Vehicles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22702·2021-10-21

    Husqvarna and GASGAS Off-Road Motorcycles Recalled for Front Brake Failure

    About 1,840 Husqvarna and GASGAS off-road competition motorcycles sold from May through August 2021 are being recalled because retaining clips on the front brake caliper can fall out, causing brake failure and crash hazard. No injuries have been reported.

    Product
    Husqvarna and GASGAS Off-Road closed course competition motorcycles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21204·2021-09-29

    Luyuan Youth ATVs Recalled for Crash Hazard and Safety Standard Violation

    Luyuan Inc. is recalling about 6,800 youth all-terrain vehicles sold from August 2018 through August 2020 because they fail to comply with federal ATV safety standards, including maximum speed limitations required for children under 10.

    Product
    Luyuan Youth All-Terrain Vehicles (ATVs)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21784·2021-09-23

    Polaris Phoenix 200 ATVs Recalled for Crash Hazard

    Polaris is recalling about 13,000 model year 2011–2021 Phoenix 200 ATVs because the throttle speed control stop can break and become stuck, posing a crash hazard. The company has received 18 reports of throttle stop failure including one crash with minor injury.

    Product
    Model Year 2011-2021 Phoenix 200 ATV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21783·2021-09-16

    Textron E-Z-GO and Tracker Off-Road Vehicles Recalled for Parking Brake Failure

    Textron Specialized Vehicles recalled approximately 6,600 E-Z-GO PTVs and Tracker Off-Road Vehicles because the parking brake catch bracket can wear out and fail, creating a crash hazard. Consumers should stop using the vehicles immediately.

    Product
    E-Z-GO PTVs and Tracker Off-Road Vehicles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21776·2021-08-19

    John Deere Compact Utility Tractors Recalled for Wheel Detachment Risk

    Deere & Company is recalling approximately 200 John Deere compact utility tractors (models 4044M, 4044R, 4052M, 4052R, 4066M, 4066R) because rear wheel spacer bolts can be improperly torqued during manufacturing, causing the wheel to fall off and the tractor to overturn.

    Product
    John Deere compact utility tractors
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21766·2021-07-22

    Polaris RZR Off-Road Vehicles Recalled for Fire Hazard

    Polaris is recalling about 1,700 Model Year 2021 RZR Pro XP and RZR Pro XP 4 recreational off-road vehicles because a raised edge on the turbocharger casting can cause an oil leak and fire hazard.

    Product
    Model Year 2021 RZR Pro XP and RZR Pro XP 4 Recreational Off-Road Vehicles (ROVs)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21765·2021-07-22

    Polaris GENERAL Recreational Off-Highway Vehicles Crash Hazard Recall

    Polaris is recalling Model Year 2021 GENERAL 1000, GENERAL 4 1000, GENERAL XP 1000, and GENERAL XP 4 1000 recreational off-highway vehicles because a weld between the brake pedal pivot bracket and EPS mounting bracket can separate, resulting in loss of brake function.

    Product
    Model Year 2021 GENERAL 1000, GENERAL 4 1000, GENERAL XP 1000 and GENERAL XP 4 1000 ROVs
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21767·2021-07-22

    Can-Am Defender HD10 Side-by-Side Vehicles Recalled for Fire Hazard

    BRP is recalling about 34,400 model years 2020 and 2021 Can-Am Defender HD10 side-by-side vehicles because the CVT air intake can become obstructed with snow, causing the drive belt to overheat and break and creating a fire hazard. BRP has received three reports of fires but no injuries.

    Product
    Model Years 2020 and 2021 Can-AM Defender HD10 side-by-side vehicles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21753·2021-06-10

    2021 Can-Am Outlander and Renegade ATVs Recalled for Crash Hazard

    BRP is recalling about 4,600 model year 2021 Can-Am Outlander and Renegade ATVs because the steering knuckle can detach from the lower arm, causing loss of control and crash risk.

    Product
    2021 Can-Am Outlander and Renegade ATVs
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21748·2021-05-20

    John Deere Recalls Gator Utility Vehicles Due to Crash Hazard

    John Deere is recalling about 90 Gator utility vehicles because a software error can cause the speedometer and safety systems to fail, posing a crash risk.

    Product
    John Deere XUV590 and XUV590 S4 Gator™ utility vehicles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21744·2021-05-13

    Polaris Recalls 2021 RZR PRO XP Vehicles Due to Fire Hazard

    Polaris is recalling about 32 Model Year 2021 RZR PRO XP and RZR PRO XP 4 off-road vehicles because a missing copper seal washer can cause an oil leak and fire hazard.

    Product
    Model Year 2021 RZR PRO XP and RZR PRO XP 4 (ROVs)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·21742·2021-05-06

    CFMOTO Recalls 2021 CFORCE 800XC ATVs Due to Crash Hazard

    CFMOTO is recalling about 2,050 2021 CFORCE 800XC ATVs because the electronic power steering can malfunction, causing loss of control and posing a crash hazard.

    Product
    2021 CFORCE 800XC All-Terrain Vehicles (ATVs)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21738·2021-04-22

    Kawasaki Recalls 2021 BRUTE FORCE 750 ATVs Due to Fire Hazard

    Kawasaki is recalling about 70 2021 BRUTE FORCE 750 ATVs because loose fuel pump bolts can cause fuel leaks and fire. No injuries have been reported.

    Product
    BRUTE FORCE® 750 All-Terrain Vehicles (ATVs)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21733·2021-03-25

    KTM, Husqvarna, and GASGAS Recall Competition Motorcycles Due to Crash Hazard

    KTM, Husqvarna, and GASGAS are recalling about 1,470 model year 2021 closed course competition motorcycles because the drive chain can break, posing a crash hazard.

    Product
    KTM, Husqvarna and GASGAS closed course competition motorcycles
    Category
    Vehicle
    Distribution
    Distributed nationwide