Valorem Surgical Recalls Pallas M Cross Link Torque Handles
Valorem Surgical LLC is recalling 262 Pallas M/MAXIMIS Cross Link Torque Handles because they are not consistent with Quality System Requirements.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 2/5 (Moderate).
Minor labeling or packaging issue, or a voluntary precautionary recall. Risk of harm is low but real — follow the manufacturer's instructions.
Our severity reasoning: The recall is classified as FDA Class II, and the source text cites a failure to meet Quality System Requirements without reporting specific injuries, illnesses, or deaths. This aligns with the rubric for moderate severity involving low-risk contamination or voluntary precautionary recalls where no harm is reported.
Plain-English summary
Valorem Surgical LLC is recalling 262 units of the Pallas M/MAXIMIS Cross Link Torque Handle, which is part of the MAXIMIS Pedicle Screw Spinal Fixation System. The product is intended for posterior pedicle screw fixation of the non-cervical spine. The recall is being conducted because the devices are not consistent with Quality System Requirements.
The affected products are identified by Catalog No. 0703-0030 and Known Lot No. WNV111109. The products were distributed nationwide in the United States, including California and Virginia. The product was labeled as the Pallas M Spinal Fixation System through 2015.
The source text does not specify specific actions for consumers or healthcare providers beyond the recall notice itself.
The recalled product
- Product
- PALLAS M/MAXIMIS Cross Link Torque Handle. Part of MAXIMIS Pedicle Screw Spinal Fixation System. Valorem Surgical, Chicago, IL. Product labeled as Pallas M Spinal Fixation System through 2015. Intended for posterior pedicle screw fixation of the non-cervical spine.
- Manufacturer
- Valorem Surgical LLC
- Category
- Medical Device — Spinal Fixation
- Affected units
- 262
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (2)
- Catalog No. 0703-0030
- Known Lot No. WNV111109.
Distribution
Part of a larger recall action
This product is one of 144 recalled by Valorem Surgical LLC under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 144 products in this recall →Related recalls
Same manufacturer · Valorem Surgical LLC
See all →- ModerateValorem Surgical Recalls Pallas M/MAXIMIS 40mm Rods for Quality Issues
FDA (Devices) · 2017-08-16
- ModerateValorem Surgical Recalls Pallas M/MAXIMIS MIS Tapper 5.5mm Spinal Fixation Devices
FDA (Devices) · 2017-08-16
- ModerateValorem Surgical Recalls Pallas M/MAXIMIS 60mm Spinal Fixation Rods
FDA (Devices) · 2017-08-16
- ModerateValorem Surgical Recalls Pallas M Tapper Spinal Fixation Devices
FDA (Devices) · 2017-08-16
- ModerateValorem Surgical Recalls Pallas M 50mm Curved Rods for Quality Issues
FDA (Devices) · 2017-08-16
Same hazard · quality system non compliance
See all →- HighDiagnostic test products recalled by Universal Meditech for missing FDA clearance
FDA (Devices) · 2023-11-01
- HighUnauthorized Distribution of Multiple Diagnostic Tests Recalled by Universal Meditech
FDA (Devices) · 2023-11-01
- ModeratePregnancy test strips recalled for lack of FDA authorization and quality documentation
FDA (Devices) · 2023-11-01
Similar recalls
- ModerateBiomet Recalls Lineum HF Torque Handle Limit Due to Component Updates
FDA (Devices) · 2015-04-29
- ModerateBiomet Recalls Torque Limiting Handles for Spinal Fixation Devices
FDA (Devices) · 2015-04-29
- SevereFDA Recalls Zimmer Biomet Vital MIS Spinal Fixation Implants
FDA (Devices) · 2020-06-10
- HighOrthofix Firebird Spinal Fixation System Torque Limiting Handle Recall
FDA (Devices) · 2016-02-17
- HighZimmer Biomet Recalls Vital MIS Spinal Fixation System Implants
FDA (Devices) · 2020-06-10
- SevereZimmer Biomet Recalls Vital MIS Spinal Fixation Implants Due to Locking Failure
FDA (Devices) · 2020-06-10