Infusomat Space Infusion Pump Recall Due to Sensor Malfunction
B Braun is recalling the Infusomat Space Infusion Pump due to a sensor malfunction that can trigger false alarms, risking improper medication delivery.
The agency’s classification
FDA (Devices): Class I
Class I is a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: This is an FDA Class I recall, which requires a minimum severity score of 4. Although no injuries or deaths have been reported, the potential for device malfunction in a critical infusion system that delivers medication justifies the Severe classification.
Plain-English summary
B Braun Medical Inc is recalling the Infusomat Space Infusion System/Large Volume Pump (Product Code 8713050U) due to a potential malfunction in the upstream occlusion sensor. The sensor can cease proper function due to buildup of electrostatic charge during normal operation, which can trigger false occlusion alarms (both downstream and upstream).
Fourteen units have been distributed in the United States to facilities in Alabama, California, Georgia, Illinois, Michigan, and Texas. Specific serial numbers have been identified for the affected units.
This recall extends a previous recall (RES 92978) as additional devices have been identified as affected. Facilities and healthcare providers with these devices should contact B Braun Medical Inc immediately for recall details and guidance.
The recalled product
- Product
- Infusomat Space Infusion System/ Large Volume Pump, Product Code 8713050U
- Manufacturer
- B Braun Medical Inc
- Category
- Medical Device — Infusion Pump
- Affected units
- 14
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (14)
- UDI-DI (GUDID) - 04046963716752 Serial Numbers 52226
- 107529
- 123259
- 123815
- 123843
- 139003
- 147678
- 147721
- 147725
- 239018
- 239165
- 239231
- 239279
- 339337
Distribution
Related recalls
Same manufacturer · B Braun Medical Inc
See all →- CriticalB. Braun Recalls Sodium Chloride Injection Due to Particulate Matter
FDA (Drugs) · 2026-09-16
- LowB Braun Recalls Discofix Stopcock Sets Due to Incorrect Expiration Date
FDA (Devices) · 2026-09-09
- SevereB. Braun Recalls Lactated Ringer's Injection Due to Particulate Matter
FDA (Drugs) · 2026-09-02
- ModerateB. Braun UPMC double catheter trays contain Mastisol with cracking tubing
FDA (Devices) · 2026-06-10
- ModerateB. Braun spinal epidural kits contain Mastisol with cracking tubing
FDA (Devices) · 2026-06-10
Similar recalls
- SevereB. Braun Infusomat Large Volume Pump may stop delivering medication due to false alarm
FDA (Devices) · 2023-11-01
- SevereInfusomat Large Volume Pump False Occlusion Alarm May Interrupt Medication
FDA (Devices) · 2023-11-01
- HighInfusomat SPACE Pump IV Set Recalled Due to Backcheck Valve Malfunction
FDA (Devices) · 2024-07-24
- HighInfusomat SPACE Pump IV Sets Recalled for Backcheck Valve Malfunction
FDA (Devices) · 2024-07-24
- HighInfusomat SPACE IV Pump Set Recalled for Backcheck Valve Malfunction
FDA (Devices) · 2024-07-24
- SevereB.Braun Infusion Pump Administration Set Recalled for Potential Leaks
FDA (Devices) · 2019-10-02