Medline Electric Surgical Clipper Recalled for Overheating Charger Base
Medline Industries is recalling 500 electric surgical clippers because a defective circuit board component may cause the charger base to overheat and malfunction.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a risk-of-harm product (overheating electrical component) where injury has not yet been reported, fitting the 'High' severity criteria for theoretical hazards without confirmed harm.
Plain-English summary
Medline Industries Inc is recalling 500 units of the Medline Electric Surgical Clipper and Base, reference number DYND70800. The product is intended for the removal of body hair from patients prior to surgery or other minor procedures. The affected units were distributed nationwide in the United States.
The recall is being conducted due to a potential defective component on the circuit board. This defect may cause the charger base to overheat, which could result in a charger base malfunction. The source text does not report any specific injuries, illnesses, or deaths associated with this defect.
Consumers who have this product should stop using it and contact Medline Industries Inc for further instructions. The recall is classified as Class II by the FDA, indicating that use of the product could cause temporary or medically reversible health consequences, or where the probability of serious adverse health consequences is remote.
The recalled product
- Product
- MEDLINE ELECTRIC SURGICAL CLIPPER AND BASE, REF DYND70800 Product Usage: Medline Surgical Clipper is intended for the removal of body hair from the patient as required prior to surgery or other minor procedures.
- Manufacturer
- Medline Industries Inc
- Hazard
- Affected units
- 500
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- 14G1
Distribution
Distributed nationwide across the United States.
Related recalls
Same manufacturer · Medline Industries Inc
See all →- HighMedline Chest Tube Kit Recalled for Non-Sterile Tape Component
FDA (Devices) · 2022-09-14
- ModerateMedline Hand Sanitizer Foam Recalled for Defective Containers
FDA (Drugs) · 2021-12-29
- ModerateBedside PICC CDS Convenience Kit Recalled for Expired Saline Component
FDA (Devices) · 2021-12-22
- HighMedline Venous Access Pack-LF Recalled for Expired Saline Component
FDA (Devices) · 2021-12-22
- HighEVLP Convenience Pack Recalled for Expired Injectable Component
FDA (Devices) · 2021-12-22
Same hazard · overheating
See all →- Severe3M Recalls Scotch Thermal Laminators Due to Fire Hazard
CPSC · 2026-10-15
- SevereIntellijoint Navigation Systems Recalled for Potential Fire Risk
FDA (Devices) · 2026-10-14
- CriticalINMO Air3 Smart Glasses Recalled for Overheating Burn Hazard
CPSC · 2026-09-24
- HighGentherm Medical Recalls Blanketrol III Thermal Regulating Systems
FDA (Devices) · 2026-08-26
- ModerateGentherm Medical Recalls Blanketrol II Thermal Regulating Systems
FDA (Devices) · 2026-08-26
Similar recalls
- SevereMedline Electrical Surgical Clippers Recalled for Overheating Charging Base
FDA (Devices) · 2015-08-26
- High3M Surgical Clipper Recalled for Overheating Risk During Charging
FDA (Devices) · 2019-02-06
- HighMedline cardiovascular draping and basin kits contain substandard catheters
FDA (Devices) · 2026-06-24
- High3M Surgical Clipper Professional 9681 Recalled for Battery Degradation Risk
FDA (Devices) · 2018-03-07
- Critical
- HighUnimed Recalls Medline Electrosurgical Electrodes Due to Sterility Concerns
FDA (Devices) · 2012-09-05