DePuy Synthes Recalls TI Vectra Plates Due to Missing Clips
Synthes, Inc. is voluntarily recalling 16 units of TI Vectra Plates because clips may be missing. The plates are used for cervical spine fixation.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a medical device with a potential defect (missing clips) that could affect the intended function of the device, but the source text does not report any injuries or illnesses, placing it in the 'High' category for risk-of-harm products where injury has not yet been reported.
Plain-English summary
Synthes, Inc. is initiating a voluntary recall of 16 units of DePuy Synthes TI Vectra Plates. These plates are part of the Vectra Anterior Cervical Plate Family of Systems, which are intended for anterior screw fixation to the cervical spine (C2-C7). The recall affects specific lots of the TI Vectra-One Plate 2 Level / 34 mm, TI Vectra Plate 3 Level / 57 mm, and TI Vectra Plate 4 Level / 64 mm.
The recall was initiated because it was discovered that clips are potentially missing from the TI Vectra Plates in certain lots. The affected units were distributed in the United States to the states of Illinois, South Carolina, Virginia, Texas, Massachusetts, North Carolina, Louisiana, California, Alabama, Colorado, Nebraska, Oregon, and Kansas, as well as internationally to Canada.
Healthcare providers and patients should check their inventory or medical records for the specific part and lot numbers listed in the recall notice. If the affected plates are identified, they should be removed from use and returned to Synthes, Inc. according to the company's instructions.
The recalled product
- Product
- DePuy Synthes TI Vectra Plates: TI Vectra-One" Plate 2 Level / 34 mm part 04.613.184 3337672 TI Vectra" Plate 3 Level / 57 mm part 04.613.257 lot 3693878 TI Vectra" Plate 4 Level / 64 mm part 04.613.364 lot 8143905
- Manufacturer
- Synthes, Inc.
- Hazard
- Affected units
- 16
Distribution
Related recalls
Same manufacturer · Synthes, Inc.
See all →- ModerateSynthes Recalls MatrixNEURO Screws Due to Incorrect Body Clip Labeling
FDA (Devices) · 2020-08-05
- ModerateSynthes Recalls 2.4mm Sterile Locking Screws Due to Packaging Defect
FDA (Devices) · 2020-02-05
- ModerateSynthes Recalls 2.4mm Sterile Locking Screws Due to Packaging Defect
FDA (Devices) · 2020-02-05
- ModerateSynthes Recalls 2.4mm Sterile Locking Screws Due to Packaging Defect
FDA (Devices) · 2020-02-05
- ModerateSynthes 2.4mm Sterile Locking Screw Recall Due to Packaging Defect
FDA (Devices) · 2020-02-05
Same hazard · missing component
See all →- ModeratePhilips DigitalDiagnost C90 delivered without required wall stand seismic kit
FDA (Devices) · 2026-06-17
- ModerateMahurkar Elite PASS trays shipped without the labeled Tegaderm CHG dressing
FDA (Devices) · 2026-06-17
- HighExactech Equinoxe core instrument kits may have handles missing cross-pins
FDA (Devices) · 2026-03-18
- HighExactech Ergo modular impactor handle may be missing its cross-pin
FDA (Devices) · 2026-03-18
- ModerateCetrorelix injection kits recalled over missing or duplicated needles inside
FDA (Drugs) · 2026-02-18
Similar recalls
- ModerateDePuy Spine Recalls SKYLINE Anterior Cervical Plate Screws
FDA (Devices) · 2016-11-30
- HighSynthes Spine Vectra Adjustable Drill Stop Recalled for Slip Risk
FDA (Devices) · 2013-02-13
- ModerateDePuy Spine Recalls SKYLINE Anterior Cervical Plate System Screws
FDA (Devices) · 2016-11-30
- HighSynthes Spine Drill Bit Recalled for Potential Drill Stop Slippage
FDA (Devices) · 2013-02-13
- HighDePuy Synthes LCP Plate Recall Due to Dimensional Tolerance Issues
FDA (Devices) · 2020-08-26
- ModerateSynthes Recalls Cervical Spine Screws Due to Lot Swapping Error
FDA (Devices) · 2016-04-27