Femur nail surgical implant mislabeled with incorrect product length
Smith & Nephew recalled a femur nail surgical implant because some packages contained a 40cm product instead of the labeled 36cm version. No injuries have been reported.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: This is a Class II FDA recall of a surgical implant with incorrect product shipped in certain packages. While no illnesses or injuries have been reported, a femur nail of incorrect length (40cm instead of 36cm) represents a risk-of-harm product that could affect surgical outcomes and patient safety.
Plain-English summary
Smith & Nephew, Inc. is recalling the TRIGEN TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 36CM 130 DEGREE LEFT femur surgical implant. The recall was initiated after a complaint indicated that certain packages contained a 40cm version of this product instead of the labeled 36cm version.
A mismatch between the labeled product specifications and the actual product shipped could result in the wrong implant size being used during surgical procedures. This could affect surgical outcomes and proper implant fit.
Thirty units of the affected product (Batch Number 21KSM0598, UDI/DI 03596010500922) have been distributed to healthcare providers in the United States, United Arab Emirates, Canada, Germany, Spain, United Kingdom, Mexico, Panama, and Poland. Healthcare providers should verify that the physical product matches the label before use and contact the manufacturer with any questions or concerns.
The recalled product
- Product
- TRIGEN TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 36CM 130 DEGREE LEFT, REF 71647336, Femur nail
- Manufacturer
- Smith & Nephew, Inc.
- Affected units
- 30
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (2)
- UDI/DI 03596010500922
- Batch Number 21KSM0598
Distribution
Part of a larger recall action
This product is one of 2 recalled by Smith & Nephew, Inc. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 2 products in this recall →Related recalls
Same manufacturer · Smith & Nephew, Inc.
See all →- HighTRIGEN proximal humeral nails are missing their distal holes
FDA (Devices) · 2026-06-24
- ModerateBone fixation screws recalled over a labeling error on one lot
FDA (Devices) · 2025-12-24
- ModerateSmith & Nephew Lag/Compression Screw Kit Undersized Socket Defect
FDA (Devices) · 2025-05-28
- HighBIORAPTOR Suture Anchors Recalled for Sterile Barrier Packaging Breach
FDA (Devices) · 2024-12-11
- HighSmith & Nephew Bipolar Hip Implant Component Recalled for Oversized Retainer Ring
FDA (Devices) · 2024-11-13
Same hazard · product mismatch
See all →- ModerateINSPIRA AIR Balloon Dilation System packaging error corrected nationwide
FDA (Devices) · 2025-05-14
- HighSmith & Nephew Knee Prosthesis Component Packaging Error: Wrong Implant Shipped
FDA (Devices) · 2024-11-06
- HighOlympus Hemostasis Probe Mispackaged with Wrong Connector Type
FDA (Devices) · 2024-04-17
- HighOrthopedic Bone Fixation Plates Recalled for Incorrect Product Packaging
FDA (Devices) · 2023-03-08
- ModerateBiopsy marker device recalled for label and contents mismatch
FDA (Devices) · 2023-02-08
Similar recalls
- ModerateSmith & Nephew Recalls Trigen Intertan Bone Fixation Nails for Packaging Error
FDA (Devices) · 2021-01-13
- SevereSmith & Nephew Recalls Trigen Intertan Nails Due to Manufacturing Error
FDA (Devices) · 2014-05-28
- SevereSmith & Nephew Recalls Trigen Intertan 1.5 Nails Due to Manufacturing Error
FDA (Devices) · 2014-05-28
- HighSmith & Nephew Knee Prosthesis Recalled for Wrong Size Shipped
FDA (Devices) · 2024-11-06
- ModerateSmith & Nephew Recalls Mislabelled Trigen Internal Hex Reconstruction Screws
FDA (Devices) · 2013-03-20
- HighINTERTAN 1.5 nail orthopedic implants recalled due to reversed left-right labeling
FDA (Devices) · 2022-06-01