Hero Model 100 Smart Pill Dispenser Recalled for Software Dose-Prompting Error
Hero Health is recalling the Model 100 smart pill dispenser due to a software defect causing the device to prompt users to take medication doses that have already been dispensed, creating overdose risk.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: This is a risk-of-harm medical device defect. The software error creates potential for unintended double-dosing of medication. Although FDA Class II indicates agency concern, absence of reported injuries limits the severity to High per the rubric for risk-of-harm products without materialized harm.
Plain-English summary
Hero Health is recalling the Hero Model 100 (H-100) smart pill dispenser and its associated medication management app due to a software defect. The recall involves 12,039 units with software version V2.04.012 distributed nationwide throughout the United States.
The defect causes the dispenser to prompt users to take medication doses that have already been dispensed. This creates the potential for users to take duplicate doses of their medication, which could result in medication overdose or other adverse effects from excessive medication dosing.
Further information about this recall is available through Hero Health and the FDA.
The recalled product
- Product
- The Hero Model 100 (H-100) is a system consisting of a smart pill dispenser and a medication management app.
- Manufacturer
- Hero Health
- Category
- Medical Device
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- Model 100 (H-100) Catalog Number: F00002 Hero 100 V1.4
Distribution
Distributed nationwide across the United States.
Related recalls
Same hazard · medication error
See all →- HighIV Administration Sets from Windstone Medical for Infusion Pump Systems
FDA (Devices) · 2026-04-29
- HighMedline Industries IV Administration and Extension Sets Recalled Due to Potential Leaks
FDA (Devices) · 2026-02-25
- HighBD Pyxis Medication Dispensing Systems Software Sync Error Recall
FDA (Devices) · 2025-03-26
- ModeratePrescription statin LIVALO tablets recalled due to foreign tablets in bottles
FDA (Drugs) · 2025-03-19
- HighPyxis Medication and Anesthesia Dispensing Systems Recalled for Software Vulnerabilities
FDA (Devices) · 2025-02-19
Similar recalls
- HighHospira MedNet Software Recall for Dosing Unit Transmission Defect
FDA (Devices) · 2014-07-16
- SevereBaxter Exactamix Pro 1200 Software Error Causes Medication Over-delivery
FDA (Devices) · 2024-02-28
- ModerateBaxter Spectrum IQ Infusion System Recalled for Potential Software Error
FDA (Devices) · 2020-12-30
- HighICU Medical Plum Solos Infusion Pump Software Safety Defect Recall
FDA (Devices) · 2025-06-25
- HighMedical Device Software May Display Duplicate Medication Doses
FDA (Devices) · 2023-10-04
- SevereSpectrum IQ Infusion Pump Safety Software Recalled for Drug Identifier Mismatch
FDA (Devices) · 2021-08-18