Aesculap S4 Polyaxial Screws Recalled for Potential Channel Tolerance Defect
Aesculap Implant Systems LLC is recalling S4 Element 4.5mm Polyaxial Screws because the screw channel may be out of tolerance, potentially preventing the screw head from locking to the bone.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a structural defect in a medical device that could lead to device failure and potential patient harm, but no specific injuries or illnesses are reported in the source text, fitting the 'High' severity criteria for risk-of-harm products without reported injury.
Plain-English summary
Aesculap Implant Systems LLC is recalling Aesculap S4 Element 4.5mm Polyaxial Screws (ST240T, ST241T, ST242T, ST243T, ST244T, and ST245T). The S4 Spinal System is intended for anterior/anterolateral and posterior, non-cervical pedicle and non-pedicle fixation in skeletally mature patients. The recall covers all distributed lots and serial numbers, with nationwide distribution including Illinois, Minnesota, Nevada, Oklahoma, and Texas.
The recall is due to a possibility that the screw channel holding the rod in place may be out of tolerance. If the channel depth is insufficient, the rod may not provide adequate compression on the insert, which can prevent the screw head from locking down to the bone screw.
Healthcare providers and patients should contact Aesculap Implant Systems LLC for further instructions regarding the recall and potential replacement or repair of the devices.
The recalled product
- Product
- Aesculap S4 Element 4.5mm Polyaxial Screws (ST240T, ST241T, ST242T, ST243T, ST244T, and ST245T). The S4 Spinal System is intended for anterior/anterolateral and posterior, non-cervical pedicle and non-pedicle fixation. Fixation is limited to skeletally mature patients and is…
- Manufacturer
- Aesculap Implant Systems LLC
- Affected units
- 5
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- All distributed lots and serial numbers
Distribution
Related recalls
Same manufacturer · Aesculap Implant Systems LLC
See all →- HighTrocar with oversized shaft obscures surgical view in brain operations
FDA (Devices) · 2023-09-13
- ModerateAesculap Surgical Needle Recalled for Incorrect Product Code Marking
FDA (Devices) · 2023-07-26
- HighAesculap Caiman Articulating Surgical Device Recalled for Loose Spring
FDA (Devices) · 2023-05-17
- ModerateCaspar Cervical Retractor Basket Lids Recalled for Incorrect GTIN Labeling
FDA (Devices) · 2023-05-03
- HighAesculap ENNOVATE Spine Implants Recalled for Incorrect Screw Inclusion
FDA (Devices) · 2022-09-07
Same hazard · structural defect
See all →- SevereSubaru Recalls 2026 Forester and Crosstrek for Ball Joint Defect
NHTSA · 2026-10-19
- SevereVolvo Recalls 2025-2026 VNL Trucks for Loose Structural Bolts
NHTSA · 2026-10-15
- Severe
- SevereVolvo Recalls EX30 and EX30CC Vehicles for Head Restraint Defect
NHTSA · 2026-10-09
- Severe
Similar recalls
- HighAesculap S4 Cervical Cross Connector Spinal Implant System Recalled for Clamping Failure
FDA (Devices) · 2022-07-27
- HighAesculap S4 Cervical Cross Connector Recalled Due to Clamping Force Defect
FDA (Devices) · 2022-07-27
- HighSpinal fusion cross connector recalled for insufficient clamping force
FDA (Devices) · 2022-07-27
- HighAesculap S4 Cervical Revision Instruments Recalled for Tolerance Issues
FDA (Devices) · 2012-07-11
- HighSpinal Fusion Implant Cross Connectors Recalled for Insufficient Clamping Force
FDA (Devices) · 2022-07-27
- SevereAesculap S4C Occiput Torque Wrench Recalled Due to Reassembly Defect
FDA (Devices) · 2015-08-12