DeRoyal Enteral Safe Feeding Tubes Recalled for Connector Detachment
DeRoyal Industries is recalling specific polyurethane feeding tubes because the connector may detach from the tube.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall is classified as FDA Class II, and the hazard involves a structural defect in a medical device that poses a risk of harm, but no specific injuries or illnesses are reported in the source text.
Plain-English summary
DeRoyal Industries Inc is recalling certain DeRoyal Enteral Safe Feeding Tubes due to a product concern where the connector has detached from the feeding tube. The recall affects four specific reference numbers: 54-2450R, 54-2465R, 54-2480R, and 54-3680R. The affected units are polyurethane feeding tubes of varying French sizes and lengths.
The recall involves 180 cases of 10 units each. The products were distributed nationwide in the United States, specifically in the states of North Dakota, Texas, Illinois, Ohio, New Mexico, Utah, New Brunswick, Kentucky, and Colorado. Specific lot numbers are associated with each reference number, including 142844 and 143130 for REF 54-2450R, 142843 for REF 54-2465R, 142870 for REF 54-2480R, and 142842 for REF 54-3680R.
Consumers and healthcare providers should check their inventory for these specific reference numbers and lot numbers. If the product matches the recalled items, it should be stopped from use and returned to the supplier or DeRoyal Industries Inc for further instructions.
The recalled product
- Product
- DeRoyal Enteral Safe Feeding Tubes: a) REF 54-2450R, 5 FR x 24" Polyurethane b) REF 54-2465R, 6.5 FR x 24" Polyurethane c) REF 54-2480R, 8 FR x 24" Polyurethane d) REF 54-3680R, 8 FR x 36" Polyurethane Product Usage: Feeding tube
- Manufacturer
- DeRoyal Industries Inc
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (6)
- a) REF 54-2450R
- Lot Numbers: 142844
- 143130 b) REF 54-2465R
- Lot Numbers: 142843 c) REF 54-2480R
- Lot Numbers: 142870 d) REF 54-3680R
- Lot Numbers: 142842
Distribution
Related recalls
Same manufacturer · DeRoyal Industries Inc
See all →- ModerateDeRoyal Myocardial Probe Recall Due to Incorrect Needle Length
FDA (Devices) · 2026-09-30
- ModerateVascular Access Dressing Recalled Due to Lack of Sterility Assurance
FDA (Devices) · 2026-06-10
- HighDeRoyal Suction Connector Tubing Recalled for Assembly and Function Issues
FDA (Devices) · 2025-03-12
- HighDeRoyal AMG Suction Connector Tubing connection may fail to seal
FDA (Devices) · 2025-02-26
- HighDeRoyal Children's Orthopedic Tracepack Smoke Evacuation Pencil Malfunction Recall
FDA (Devices) · 2024-11-13
Same hazard · structural defect
See all →- SevereSubaru Recalls 2026 Forester and Crosstrek for Ball Joint Defect
NHTSA · 2026-10-19
- Severe
- SevereVolvo Recalls 2025-2026 VNL Trucks for Loose Structural Bolts
NHTSA · 2026-10-15
- Severe
- Severe
Similar recalls
- ModerateDeRoyal Enteral Safe Feed Tube Recall Due to Incorrect Sizing
FDA (Devices) · 2019-01-23
- HighCanadian Hospital Specialties Recalls Polyurethane Feeding Tubes Due to Connector Detachment
FDA (Devices) · 2019-08-21
- HighBenlan Pediatric Feeding Tubes Recalled for Incorrect Size Packaging
FDA (Devices) · 2016-01-13
- SevereEndotracheal tubes recalled for 15mm connector disconnection risk
FDA (Devices) · 2023-07-05
- SevereEndotracheal Tubes Recalled Due to Connector Disconnection Issues
FDA (Devices) · 2023-07-05
- SevereEndotracheal Tubes Recalled for Connector Disconnection by Teleflex
FDA (Devices) · 2023-07-05