GE OEC Recalls 9800 Fluoroscopic X-Ray Systems Due to Hard Drive Defects
GE OEC is recalling 9800 fluoroscopic x-ray systems because a replacement hard drive can cause system shutdowns, data loss, or data corruption.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a medical device with a defect that can cause system shutdowns and data loss, which poses a risk of harm to patients during procedures, but no injuries or illnesses have been reported.
Plain-English summary
GE OEC Medical Systems, Inc. is recalling certain 9800 Image Intensified Fluoroscopic x-ray systems. The recall is based on customer complaint analysis indicating that a replacement Hitachi 160 GB Hard Drive, when installed on certain models, is susceptible to causing unanticipated system shutdowns, no boots, data loss or data mix, or unexpected hard drive corruption.
The affected systems are designed to provide fluoroscopic and spot film imaging of patients during diagnostic surgical and interventional procedures. These systems are intended for use in diagnostic and interventional cardiac imaging, as well as cholangiography, endoscopic, urologic, orthopedic, neurologic, vascular, critical care, and emergency room procedures.
The recall involves 3,595 units distributed worldwide, including nationwide distribution in the United States. The specific model number is HDS721616PLAT80, and the GE Healthcare part number is 5304649. Healthcare facilities should contact GE OEC Medical Systems for further instructions on how to address the hard drive issue.
The recalled product
- Product
- 892.1650 Image-intensified fluoroscopic x-ray system; the device is designed to provide fluoroscopic and spot film imaging of the patient during diagnostic surgical and interventional procedures. The systems include features specifically designed for use in diagnostic and…
- Manufacturer
- GE OEC Medical Systems, Inc
- Hazard
- Affected units
- 3,595
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (2)
- Model Number HDS721616PLAT80
- GE Healthcare part number 5304649.
Distribution
Distributed nationwide across the United States.
Related recalls
Same manufacturer · GE OEC Medical Systems, Inc
See all →- HighOEC 9900 Mobile Fluoroscopic X-Ray System Recall for Sealing Defect
FDA (Devices) · 2024-12-25
- HighGE OEC 9800 X-Ray System Recalled for Insufficient Tube Sealing
FDA (Devices) · 2024-12-25
- HighOEC 3D Mobile Fluoroscopic X-Ray System Tube Sealing Defect Recall
FDA (Devices) · 2024-12-25
- HighFluoroscopic X-Ray System Recalled for Insufficient X-Ray Tube Sealing
FDA (Devices) · 2024-12-25
- HighOEC Flexiview 8800 Image Intensifier Risks Detachment During Movement
FDA (Devices) · 2023-08-09
Same hazard · data loss
See all →- HighPhilips Fluoroscopy System Recall Over Hard Disk Drive Issue
FDA (Devices) · 2026-08-12
- SeverePhilips Allura X-Ray Systems Recalled Over Unauthorized Hard Disk Drives
FDA (Devices) · 2026-08-12
- HighRayCare 2024A SP1 Oncology Information System Software Recall
FDA (Devices) · 2026-07-08
- HighRayCare 2024A SP4 Oncology System Beam Set Delivery Note Data Loss
FDA (Devices) · 2026-07-08
- HighMint Lesion Software Data Loss During Server Connection Interruption
FDA (Devices) · 2026-05-13
Similar recalls
- HighGE OEC Medical Systems Recalls OEC 9800 Plus Digital Imaging Systems
FDA (Devices) · 2012-08-08
- ModerateGE OEC Medical Systems Recalls UroView 2800 Imaging Devices
FDA (Devices) · 2012-08-08
- SevereGE OEC 6800 Miniview X-ray System Recalled for Safety Issues
FDA (Devices) · 2012-08-01
- SevereGE OEC 8800 Flexview X-ray System Recalled for Safety Issues
FDA (Devices) · 2012-08-01
- HighGE OEC 9800 X-Ray System Recalled for Insufficient Tube Sealing
FDA (Devices) · 2024-12-25
- ModerateGE OEC 9800 Fluoroscopic X-Ray System Recalled for Monitor Firmware Issue
FDA (Devices) · 2016-08-31