ConvaTec Recalls Elongated Oxygen Masks Due to Tubing Detachment Risk
ConvaTec is recalling elongated oxygen masks because tubing may detach from the connector, potentially disrupting oxygen supply to users.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a medical device where a defect can disrupt oxygen supply, posing a risk of harm, but the source text does not report any specific injuries or illnesses, fitting the 'High' severity criteria for risk-of-harm products without reported injury.
Plain-English summary
ConvaTec, Inc. is recalling 816,709 units of Oxygen Masks, Elongated (under chin), Adult Med Conc., No Tubing, Product Code 104-E. The recall involves specific lot numbers including 102153, 102339, 102941, 103176, 103453, 103718, 103919, 104471, 105034, 105282, 105427, 105567, 105996, 106960, 108658, 112024, and 112530. These products were distributed in multiple U.S. states and internationally, including Canada, Australia, and various European and Asian countries.
The recall was initiated due to reports from different end users that the oxygen tubing detached from the mask connector either prior to use or during use. The defect is caused by an improper solvent bond between the tubing and the connector. While the issue affects less than 2% of the recalled product, it poses a potential risk of harm by disrupting the oxygen supply to the user.
Consumers and healthcare providers should stop using the affected oxygen masks and contact ConvaTec, Inc. for further instructions or a replacement.
The recalled product
- Product
- Oxygen Masks, Elongated (under chin), Adult Med Conc., No Tubing, Product Code 104-E;
- Manufacturer
- ConvaTec, Inc
- Affected units
- 816,709
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (17)
- Lot Number 102153
- 102339
- 102941
- 103176
- 103453
- 103718
- 103919
- 104471
- 105034
- 105282
- 105427
- 105567
- 105996
- 106960
- 108658
- 112024
- 112530
Distribution
Part of a larger recall action
This product is one of 18 recalled by ConvaTec, Inc under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 18 products in this recall →Related recalls
Same manufacturer · ConvaTec, Inc
See all →- HighConvaTec Esteem Body Soft Convex Urostomy Pouches Recalled for Leakage
FDA (Devices) · 2026-08-26
- ModerateAquacel Ag Surgical SP Surgical Dressing Recalled for Out-of-Specification Thickness
FDA (Devices) · 2026-07-15
- HighConvaTec EsteemBody drainable pouch REF 423657 may leak
FDA (Devices) · 2026-03-25
- HighConvaTec EsteemBody drainable pouch REF 423653 may leak
FDA (Devices) · 2026-03-25
- HighConvaTec EsteemBody drainable pouch REF 423643 may leak
FDA (Devices) · 2026-03-25
Same hazard · tubing detachment
See all →- HighPrecision Delivery Sets recalled due to potential tubing detachment
FDA (Devices) · 2023-02-15
- HighEdwards TruWave Pressure Monitoring Set Recalled for Potential Tubing Detachment
FDA (Devices) · 2021-07-07
- HighEdwards TruWave Pressure Monitoring Set Recalled Due to Tubing Detachment Risk
FDA (Devices) · 2021-07-07
- HighPressure monitoring set recalled for potential pressure tubing detachment
FDA (Devices) · 2021-07-07
- HighEdwards TruWave Pressure Monitoring Set Recalled for Potential Tubing Detachment
FDA (Devices) · 2021-07-07
Similar recalls
- HighWestmed Elongated Oxygen Mask Recalled for Loose Tube Connection
FDA (Devices) · 2021-01-06
- HighWestmed Adult Elongated Oxygen Mask Recalled for Loose Fitment
FDA (Devices) · 2021-01-06
- HighWestmed Non-Rebreather Masks Recalled for Loose Oxygen Tube Fitment
FDA (Devices) · 2021-01-06
- HighWestmed Adult Oxygen Mask Recall Due to Potential Loose Fitment
FDA (Devices) · 2021-01-06
- HighWestmed Adult Elongated CO2/O2 Mask Recall for Loose Fitment
FDA (Devices) · 2021-01-06
- HighConvaTec Recalls Opti-Mist Nebulizer Masks Due to Reduced Aerosol Output
FDA (Devices) · 2016-03-09