Ortho Recalls VITROS Chemistry Calibrator Kit 20 for Analytical Bias
Ortho-Clinical Diagnostics is recalling VITROS Chemistry Calibrator Kit 20 due to measurement bias affecting laboratory results for immunoglobulin and complement protein testing. Falsely elevated or reduced values could be reported.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: FDA Class II designation applies. While no hospitalizations or reported injuries have been documented, the measured biases (ranging from -17.8% to +35.3%) represent significant analytical error with potential for patient harm through incorrect diagnostic results, classifying this as a risk-of-harm device without yet-reported injury.
Plain-English summary
Ortho-Clinical Diagnostics is recalling VITROS Chemistry Products Calibrator Kit 20 (Product Code 6801704), used to calibrate VITROS 5,1 FS/4600 and 5600/XT 7600 chemistry analyzers. The recall affects approximately 2,400 units distributed worldwide, including the US, Australia, Brazil, Canada, Chile, China, Colombia, Denmark, France, Germany, India, Italy, Japan, Mexico, Norway, Portugal, Russia, Singapore, Spain, Sweden, The Netherlands, and the United Kingdom.
The calibrator kit can produce biased results in the upper end of the reportable range for quantitative measurement of transferrin, C3, C4, IgA, IgG, and IgM. Observed measurement biases in sample testing included: IgM +35.3%, IgG -4.3%, IgA +12.3%, C3 -6.9%, C4 -6.6%, and transferrin -17.8%. Depending on the analyte and sample concentration, laboratory results may be falsely elevated or reduced.
Affected lot code is 2022 with expiration date 06-Sept-2023 (UDI-DI: 10758750006687). Clinical laboratories using this calibrator kit should contact Ortho-Clinical Diagnostics for replacement or validation guidance. Results from affected calibrations should be reviewed for accuracy, particularly for immunoglobulin and complement protein measurements.
The recalled product
- Product
- VITROS Chemistry Products Calibrator Kit 20-in vitro diagnostic use only. VITROS Chemistry Products Calibrator Kit 20- Used to calibrate the VITROS 5,1 FS/4600 Chemistry Systems and the VITROS 5600/XT 7600 Integrated Systems for the quantitative measurement of transferrin, C3…
- Manufacturer
- Ortho-Clinical Diagnostics
- Affected units
- 2,400
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- UDI-DI: 10758750006687 Lot Code: 2022 Exp. Date :06-Sept-2023
Distribution
Distributed nationwide across the United States.
Related recalls
Same manufacturer · Ortho-Clinical Diagnostics
See all →- HighClinical Laboratory Quality Control Device Recalled for Diluent Assembly Error
FDA (Devices) · 2024-04-03
- HighLaboratory performance verifier recalled for mismatched diluent assembly
FDA (Devices) · 2024-04-03
- HighFDA Recalls Troponin Cardiac Test Calibrators for Potential False Negatives
FDA (Devices) · 2023-08-16
- HighVITROS Troponin I ES Immunodiagnostic Reagent Pack Recalled for Incorrect Wells
FDA (Devices) · 2023-08-16
- ModerateOrtho-Clinical VITROS Chemistry BuBc Slides Recalled for Etrombopag Interference
FDA (Devices) · 2020-09-02
Same hazard · measurement bias
See all →- HighEmano Flow Uroflowmetry App Recalled Over Biased Flow Estimates
FDA (Devices) · 2026-07-29
- HighStago D-dimer assay shows positive bias across entire analytical range
FDA (Devices) · 2026-03-25
- HighCapillary tubes recalled over a positive bias in potassium results
FDA (Devices) · 2026-02-25
- HighVITROS Chemistry CRP Diagnostic Slides May Underreport Elevated Results
FDA (Devices) · 2024-12-04
- Highepoc BGEM BUN Test Cards recalled for sodium measurement bias
FDA (Devices) · 2024-11-13
Similar recalls
- ModerateOrtho VITROS Chemistry Calibrator Kit 2 Recalled for False Positive Results
FDA (Devices) · 2014-03-05
- HighOrtho VITROS Chemistry Calibrator Kit 2 Recalled for Potential Sodium Bias
FDA (Devices) · 2020-02-19
- LowOrtho-Clinical Diagnostics Recalls VITROS Chemistry Products Calibrator Kit 29
FDA (Devices) · 2016-07-13
- ModerateOrtho-Clinical Diagnostics Recalls VITROS TIBC Calibrator Kits Due to Performance Shift
FDA (Devices) · 2021-03-31
- ModerateOrtho-Clinical Diagnostics Recalls VITROS Chemistry Products Calibrator Kit 17
FDA (Devices) · 2014-06-25
- ModerateOrtho-Clinical Diagnostics Recalls VITROS 5600 Chemistry Systems
FDA (Devices) · 2016-03-16