The Recall Desk
Agency classClass IIOur severity:HighFDA (Devices)·Z-1872-2020·Announced 2020-05-13

Hemashield Platinum Vascular Grafts Recalled for Potential Seam Holes

Maquet Cardiovascular is recalling Hemashield Platinum Woven Double Velour Vascular Grafts due to potential small holes at seam lines that could cause intra-operative bleeding.

The agency’s classification

FDA (Devices): Class II

Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.

This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work

What this means for you

Our assessment, not the agency’s: severity 3/5 (High).

Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.

Our severity reasoning: The recall is classified as FDA Class II, and the hazard involves a risk of harm (intra-operative bleeding) where injury has not yet been reported, fitting the criteria for a High severity score.

Plain-English summary

Maquet Cardiovascular, LLC is recalling specific units of the HEMASHIELD PLATINUM Woven Double Velour Vascular Graft- 1 Branch. The recall is due to a potential defect where small holes may exist at the seam lines of the graft branches. This defect poses a risk of intra-operative bleeding during surgical procedures.

The affected product is used for the replacement or repair of arteries affected with aneurysmal or occlusive disease. The recall covers units distributed worldwide, including the United States and various international markets such as Canada, the UK, Germany, and Japan. Specific serial numbers for the affected units are listed in the official recall documentation.

Healthcare providers and patients should check their records for the presence of these specific serial numbers. If a patient has received a graft with one of the listed serial numbers, they should contact their healthcare provider for further evaluation and guidance. No specific instructions for consumer disposal are provided in the source text, as this is a medical device used in surgical settings.

The recalled product

Product
HEMASHIELD PLATINUM Woven Double Velour Vascular Graft- 1 Branch, Product Code: M00202175828P0 - Product Usage: for use in the replacement or repair of arteries affected with aneurysmal or occlusive disease.

Distribution

Distributed nationwide across the United States.

Part of a larger recall action

This product is one of 24 recalled by Maquet Cardiovascular, LLC under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.

See all 24 products in this recall →

Similar recalls