FDA Recalls Covidien EGIA 60 Articulating Extra Thick Sulu Devices
The FDA is recalling 3,113,280 units of the EGIA 60 Articulating Extra Thick Sulu device due to a missing pin component that may cause incomplete staple formation and serious surgical complications.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The recall is classified as FDA Class II and involves a structural defect that can lead to serious medical complications such as sepsis, peritonitis, and pneumothorax, meeting the criteria for a Severe rating.
Plain-English summary
The U.S. Food and Drug Administration (FDA) is recalling 3,113,280 units of the EGIA 60 Articulating Extra Thick Sulu device, item code EGIA60AXT, manufactured by Covidien LLC. The recall was initiated because the device may be missing one of two pin components that maintain the alignment of the device jaws.
This defect can result in incomplete staple formation during use. Incomplete stapling may lead to bleeding, anastomotic leak, peritonitis, or pneumothorax. These conditions can result in the potential for infection and/or sepsis.
The affected devices were distributed nationwide domestically and worldwide to foreign locations. The specific lot codes associated with this recall are N6B0079KX and N8A0029KX. Healthcare providers and facilities should stop using these devices and contact the recalling firm for instructions on return or replacement.
The recalled product
- Product
- EGIA 60 ARTICULATING EXTRA THICK SULU, Item code EGIA60AXT
- Manufacturer
- Covidien LLC
- Affected units
- 3,113,280
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- N6B0079KX N8A0029KX
Distribution
Distributed nationwide across the United States.
Part of a larger recall action
This product is one of 12 recalled by Covidien LLC under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 12 products in this recall →Related recalls
Same manufacturer · Covidien LLC
See all →- ModerateEndoFLIP System Recall Due to Incorrect Catheter Expiration Flags
FDA (Devices) · 2026-08-26
- ModerateCovidien Shiley Disposable Decannulation Plug product labeling error
FDA (Devices) · 2026-07-08
- ModerateCovidien 9 Fr Mon-a-Therm temperature probes lack FDA clearance
FDA (Devices) · 2026-06-10
- ModerateCovidien esophageal stethoscope temperature sensors lack FDA clearance
FDA (Devices) · 2026-06-10
- ModerateShiley tracheostomy tubes recalled over incorrect display box labeling
FDA (Devices) · 2026-06-10
Same hazard · structural defect
See all →- SevereVolvo Recalls EX30 and EX30CC Vehicles for Head Restraint Defect
NHTSA · 2026-10-09
- Severe
- Severe
- SevereONTHEWEI Recalls Baby Bath Seats Due to Drowning Risk
CPSC · 2026-10-08
- SevereDecathlon Recalls Van Rysel GRVL AF Bicycles Due to Crash Hazard
CPSC · 2026-10-08
Similar recalls
- SevereEndo GIA Stapler Recall Due to Incomplete Staple Formation
FDA (Devices) · 2020-10-07
- SevereFDA Recalls Covidien Duet TRS Stapler Units Due to Injury Risk
FDA (Devices) · 2012-10-03
- HighFDA Recalls 222 Units of Covidien Tri-Staple 2.0 Reinforced Intelligent Reloads
FDA (Devices) · 2021-04-21
- SevereFDA Recalls Endo GIA Stapler Loading Units Due to Staple Formation Defect
FDA (Devices) · 2020-10-07
- SevereFDA Recalls Endo GIA Auto Suture Units Due to Staple Formation Defects
FDA (Devices) · 2020-10-07
- SevereFDA Recalls Covidien Signia Stapler Reloads Due to Safety Interlock Failure
FDA (Devices) · 2021-04-21