BD MaxGuard Extension Set labeled with incorrect expiration year 2027
46,900 BD MaxGuard Extension Sets are labeled with expiration year 2027 but should expire in 2025. Using expired product may compromise integrity and cause leaks, risking infection.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: This is an FDA Class II device recall involving a labeling error that could result in use of expired medical equipment with potential for leaks and infection risk. Although no illnesses or injuries have been reported, the product poses a direct risk of harm if used after the actual expiration date, fitting the rubric criterion for risk-of-harm products where injury has not yet been reported.
Plain-English summary
BD CAREFUSION has recalled 46,900 BD MaxGuard Extension Sets with 4-way stopcock (REF: M4058) due to incorrect expiration dates printed on product labels.
The product labels list an expiration year of 2027, but the correct expiration year is 2025. If expired product is used in clinical settings, the integrity of the extension set may be compromised, potentially resulting in leaks. Such failures could pose a risk of infection to both patients and healthcare workers.
The recalled lots include 22019324, 22019323, and 22019322 (UDI-DI: 10885403235788). Affected units were distributed across 40 U.S. states and territories. Healthcare facilities and medical professionals should immediately identify and cease use of these affected lots and contact CAREFUSION for guidance on return or replacement procedures.
The recalled product
- Product
- BD MaxGuard Extension Set with 4-way stopcock, REF: M4058
- Manufacturer
- CAREFUSION
- Affected units
- 46,900
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (4)
- UDI-DI: 10885403235788
- Lots: 22019324
- 22019323
- 22019322
Distribution
Part of a larger recall action
This product is one of 9 recalled by CAREFUSION under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 9 products in this recall →Related recalls
Same manufacturer · CAREFUSION
See all →- HighBD MaxGuard Extension Set Recalled for Incorrect Expiration Year
FDA (Devices) · 2022-09-28
- HighBD MaxGuard Extension Set Wrong Expiration Label Poses Infection Risk
FDA (Devices) · 2022-09-28
- HighBD MaxGuard Administration Set Recalled for Incorrect Expiration Date Labels
FDA (Devices) · 2022-09-28
- HighBD MaxGuard Administration Set Recalled for Incorrect Expiration Labeling
FDA (Devices) · 2022-09-28
- HighBD MaxGuard Flow Controller Extension Set recalled for mislabeled expiration dates
FDA (Devices) · 2022-09-28
Same hazard · expiration mislabeling
See all →- ModerateDisposable surgical forceps recalled for incorrect expiration date labeling
FDA (Devices) · 2023-11-15
- HighFreeman Pancreatic Flexi-Stent Kit Recall: Incorrect Expiration Date Label
FDA (Devices) · 2022-10-19
- HighHobbs Posi-Stop Injection Needles Recalled for Incorrect Expiration Date Labeling
FDA (Devices) · 2022-10-19
- ModerateHobbs Medical Cytology Brush Recalled for Incorrect Expiration Date Labeling
FDA (Devices) · 2022-10-19
- HighHobbs Biliary Pigtail Stent Kits Recalled for Incorrect Expiration Dates
FDA (Devices) · 2022-10-19
Similar recalls
- LowB Braun Recalls Discofix Stopcock Sets Due to Incorrect Expiration Date
FDA (Devices) · 2026-09-09
- HighBD Connecta Stopcock Without Extension Tube Recalled for Potential Leakage Risk
FDA (Devices) · 2022-07-27
- HighCareFusion Recalls MaxGuard Extension Sets Due to Filter Leaks
FDA (Devices) · 2017-03-22
- HighBD PhaSeal Y-Site Connector recalled for mislabeled expiration dates
FDA (Devices) · 2022-08-24
- HighBD Connecta 3-Way Stopcocks Recalled Due to Potential Leakage
FDA (Devices) · 2022-07-27
- HighBD Connecta Stopcock recalled for potential housing leakage risk
FDA (Devices) · 2022-07-27