Smith & Nephew Recalls TC-Plus Tibial Knee Prosthesis Components
Smith & Nephew is recalling 34 units of TC-Plus tibial knee prosthesis components due to a dimensional deviation that may prevent proper seating during surgery.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall is classified as FDA Class II and involves a risk-of-harm product (medical device) where the hazard is a potential surgical complication, but no injuries or illnesses have been reported.
Plain-English summary
Smith & Nephew, Inc. is recalling 34 units of TC-Plus(TM) Primary Fixed Tibial Component VKS Right, Size 8 Right, Sterile R. The affected devices are identified by Reference 12 000 026 and Serial Number 7500281. The recall covers specific batch numbers: B1514883, B1509344, B1504926, and B1502141.
The recall was initiated because the affected devices may contain a dimensional deviation. This deviation could potentially result in the surgeon being unable to seat the polyethylene (PE) insert on the affected VKS tibial base plate during surgery. The agency has classified this recall as Class II.
The affected devices were distributed internationally only in Germany and Switzerland. No illnesses or injuries have been reported in the source text. Healthcare providers and patients should contact Smith & Nephew for further instructions regarding the return or replacement of these devices.
The recalled product
- Product
- TC-PLUS(TM), Primary Fixed Tibial Component VKS Right, SIZE 8 RIGHT, STERILE R, REF 12 000 026, S&N 7500281, Smith & Nephew Orthopaedics AG Product Usage: Tibial knee prosthesis
- Manufacturer
- Smith & Nephew, Inc.
- Affected units
- 34
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (4)
- Batch numbers: B1514883
- B1509344
- B1504926
- B1502141
Distribution
Distribution scope not specified by the agency.
Part of a larger recall action
This product is one of 15 recalled by Smith & Nephew, Inc. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 15 products in this recall →Related recalls
Same manufacturer · Smith & Nephew, Inc.
See all →- HighTRIGEN proximal humeral nails are missing their distal holes
FDA (Devices) · 2026-06-24
- ModerateBone fixation screws recalled over a labeling error on one lot
FDA (Devices) · 2025-12-24
- ModerateSmith & Nephew Lag/Compression Screw Kit Undersized Socket Defect
FDA (Devices) · 2025-05-28
- HighBIORAPTOR Suture Anchors Recalled for Sterile Barrier Packaging Breach
FDA (Devices) · 2024-12-11
- HighSmith & Nephew Bipolar Hip Implant Component Recalled for Oversized Retainer Ring
FDA (Devices) · 2024-11-13
Same hazard · dimensional deviation
See all →- ModerateLaparoscopic trocars recalled over a potentially extended blade obturator length
FDA (Devices) · 2026-01-14
- ModeratePaltop Scan Abutment SP Recalled for Dimensional Tolerance Deviations
FDA (Devices) · 2021-10-13
- ModerateScan Abutment NP Dental Implant Components Recalled for Dimensional Deviations
FDA (Devices) · 2021-10-13
- HighSmith & Nephew Recalls TC-PLUS Knee Prosthesis Due to Dimensional Deviation
FDA (Devices) · 2016-04-27
- HighSmith & Nephew Recalls TC-PLUS Knee Prosthesis Due to Dimensional Deviation
FDA (Devices) · 2016-04-27
Similar recalls
- HighSmith & Nephew Recalls Tibial Knee Prosthesis Due to Material Defects
FDA (Devices) · 2020-08-19
- ModerateSmith & Nephew Recalls Legion Hemi Stepped Tibial Wedges Due to Incorrect Screws
FDA (Devices) · 2016-02-24
- HighSmith & Nephew Knee Prosthesis Recalled Due to Higher-Than-Expected Revision Rate
FDA (Devices) · 2023-06-07
- ModerateSmith & Nephew Recalls Swapped Genesis II Tibial Base Implants
FDA (Devices) · 2013-11-13
- HighGenesis II Tibial Baseplate Devices Recalled for Packaging Error
FDA (Devices) · 2022-07-27
- ModerateSmith & Nephew Recalls Mispackaged Genesis II Knee Prosthesis Components
FDA (Devices) · 2018-08-29