BioMerieux Recalls FB Reagent Due to False Negative Test Results
BioMerieux SA is recalling FB Reagent (REF 70562) and ZYM B reagent (REF 70493) because a visual defect and activity issue can cause false negative results in Rapid ID 32 and API biochemical tests.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall is classified as FDA Class II. The hazard involves false negative results in diagnostic tests, which poses a risk of harm to patients through misdiagnosis, but no specific injuries or illnesses are reported in the source text.
Plain-English summary
BioMerieux SA is recalling FB Reagent (REF 70562) and ZYM B reagent (REF 70493). The recall involves 33,853 units of FB Reagent distributed nationwide in the United States, including DC and Puerto Rico, as well as to numerous countries worldwide.
The recall was initiated because BioMerieux identified a visual defect and an activity issue in the affected reagents. This activity issue can lead to false negative results when using the ZYM B reagent or FB reagent with Rapid ID 32 strips and API biochemical tests. These test systems are used to identify microorganisms.
Healthcare facilities and laboratories should stop using the affected lots immediately. The specific lot codes and expiration dates for the recalled FB Reagent are: 1002717180 (Exp. 5/30/2014), 1002737220 (Exp. 6/13/2014), 1002778550 (Exp. 8/9/2014), 1002782960 (Exp. 8/15/2014), 1002792840 (Exp. 8/15/2014), 1002834130 (Exp. 8/22/2014), and 1002877370 (Exp. 8/22/2014). Users should contact BioMerieux SA for instructions on returning the product.
The recalled product
- Product
- FB Reagent (REF 70562). FB reagent is an additional test used for revealing the results of some miniaturized biochemical test included in the API and Rapid ID 32 strips. The API and ID 32 strips product lines are a standardized system combining several biochemical tests…
- Manufacturer
- BioMerieux SA
- Affected units
- 33,853
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (12)
- Codes - 1002717180
- Exp. Date 5/30/2014
- 1002737220
- Exp. Date 6/13/2014
- 1002778550
- Exp. Date 8/9/2014
- 1002782960
- Exp. Date 8/15/2014
- 1002792840
- 1002834130
- Exp. Date 8/22/2014
- 1002877370
Distribution
Part of a larger recall action
This product is one of 4 recalled by BioMerieux SA under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 4 products in this recall →Related recalls
Same manufacturer · BioMerieux SA
See all →- HighMYLA Diagnostic System Software Versions Recalled for Risk of False Negatives
FDA (Devices) · 2021-10-20
- HighMYLA Laboratory Software: Potential Test Result Alteration from Software Anomaly
FDA (Devices) · 2021-08-18
- ModerateBioMerieux NucliSENS Magnetic Extraction Reagents Recalled Due to Temperature Exposure
FDA (Devices) · 2018-10-31
- ModerateBioMerieux Recalls VIDAS FSH Assay Kits Due to Calibration Issues
FDA (Devices) · 2018-07-04
- ModerateBioMérieux Recalls VITEK 2 Gram Positive Susceptibility Cards Due to Temperature Excursion
FDA (Devices) · 2018-06-20
Same hazard · false negative result
See all →- HighSteris VERIFY Dual Species Biological Indicator Recall for Spore Population Issues
FDA (Devices) · 2026-10-14
- SevereSteris Recalls VERIFY Biological Steam Test Packs Due to Spore Population Concerns
FDA (Devices) · 2026-10-14
- SevereSteris VERIFY Biological Steam Test Pack Recalled for Spore Population Defect
FDA (Devices) · 2026-10-14
- ModerateDRG Sperm Ab ELISA Recalled for Potential False Negative Results
FDA (Devices) · 2026-10-14
- SevereSteris VERIFY Biological Indicator Recall Due to Spore Population Concerns
FDA (Devices) · 2026-10-14
Similar recalls
- ModerateBioMérieux Recalls ZYM B Reagent Due to Visual Defect and False Negatives
FDA (Devices) · 2014-02-05
- HighBioMerieux Recalls API ZYM Bx2 Reagent Due to False Negative Results
FDA (Devices) · 2016-02-10
- ModerateBiomerieux Recalls API Listeria Kits Due to ZYM B Reagent Defect
FDA (Devices) · 2014-02-05
- ModerateBioMérieux Recalls API NH Kits Due to ZYM B Reagent Defect
FDA (Devices) · 2014-02-05
- ModerateClinical Reagent Vitek MS-FA Recalled Due to Storage Condition Violations
FDA (Devices) · 2023-01-11
- ModerateBioMerieux Recalls Ceftriaxone ETEST Kits Due to Performance Issues
FDA (Devices) · 2017-05-31