Cook Inc. Recalls MINC Benchtop Incubators Due to Temperature Control Defect
Cook Inc. is recalling 483 MINC Benchtop Incubators because a heater failure may cause temperatures to become too high or too low for proper cell culture.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall is classified as FDA Class II. The hazard involves a risk of harm to the product's intended use (cell culture) due to temperature control failure, but no specific injuries or illnesses have been reported in the source text.
Plain-English summary
Cook Inc. is recalling 483 units of the MINC Benchtop Incubator (Mini Incubator), catalog K-MINC-1000 US, G46022. These microprocessor-controlled, gassed, and humidified incubators are intended for use in cell culture. The recall covers all lots of the product.
The recall was initiated because the temperature of the incubation lids may become too high or too low for proper gamete or embryo incubation. This issue is caused by fatigue failure of the flat flex lid heater. The affected units were distributed nationwide and worldwide.
Consumers and facilities using these incubators should stop using the product and contact Cook Inc. for further instructions on repair or replacement.
The recalled product
- Product
- MINC Benchtop Incubator (Mini Incubator) catalog (K-MINC-1000 US) G46022 is a microprocessor controlled, gassed, humidified, incubator intended for use in cell culture.
- Manufacturer
- Cook Inc.
- Affected units
- 483
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- All lots
Distribution
Distributed nationwide across the United States.
Part of a larger recall action
This product is one of 2 recalled by Cook Inc. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 2 products in this recall →Related recalls
Same manufacturer · Cook Inc.
See all →- HighSkinny Needle with Chiba Tip recalled for debris contamination
FDA (Devices) · 2021-12-29
- HighCook Flexor Check-Flo Introducer recalled for size mislabeling
FDA (Devices) · 2021-12-22
- ModerateFlexor Check-Flo Introducer Recalled for Mislabeled Caliber Size
FDA (Devices) · 2021-12-22
- HighTransseptal Needles Recalled Due to Rust Contamination Risk
FDA (Devices) · 2021-11-24
- HighTransseptal Needle with Catheter Recalled Due to Rust Contamination Risk
FDA (Devices) · 2021-11-24
Same hazard · temperature control failure
See all →- HighPepperoni Rolls Recalled for Undeclared Milk Allergen and Temperature Control Failure
FDA (Food) · 2026-07-08
- ModerateK-Systems R65 embryo incubator temperature may exceed setpoint
FDA (Devices) · 2024-12-25
- HighArctic Sun Temperature Management System software failure may disable critical safety alarms
FDA (Devices) · 2024-08-07
- HighPhilips 5000 Compact Series Ultrasound Systems pose uncontrolled burn risk
FDA (Devices) · 2024-05-15
- HighGalbani Domestic Mascarpone Recalled for Improper Temperature Storage
FDA (Food) · 2024-02-14
Similar recalls
- HighMINC+ Benchtop Incubator Recalled for Temperature Control Loss Risk
FDA (Devices) · 2024-01-24
- HighK-Systems G85 Mini Incubator May Exceed Desired Temperature
FDA (Devices) · 2024-12-25
- HighCook Medical Recalls Disposable Humidification Flasks Due to Stopper Defect
FDA (Devices) · 2021-01-20
- HighK-Systems Incubator Device Recall: Temperature May Exceed Desired Setting
FDA (Devices) · 2024-12-25
- HighK-Systems G73 Dry Bath Incubator may exceed target temperature
FDA (Devices) · 2024-12-25
- HighThermo Fisher CO2 Incubators Recalled for Hinge Failure
FDA (Devices) · 2013-04-17