Central venous catheter recalled for incorrect gravity flow rates
Arrow International is recalling the Arrow Three-Lumen CVC due to incorrect gravity flow rates on the product lidstock. The defect may affect fluid and medication delivery through the catheter.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: FDA Class II medical device recall for a functional defect in a critical medical device. No illnesses or injuries have been reported, but the defect could impact drug delivery and patient care, placing it in the category of risk-of-harm products where injury has not yet been reported.
Plain-English summary
Arrow International Inc. is recalling the Arrow Three-Lumen CVC, a medical device used for central venous access and fluid or medication administration. Approximately 10,301 units of this catheter are affected.
The recalled catheters contain incorrect gravity flow rates on the product lidstock. This defect may affect the rate at which fluids or medications flow through the catheter via gravity.
The affected units were distributed in Florida. Healthcare facilities with affected lot numbers should review this recall and take appropriate action according to facility protocol and guidance from Arrow International Inc.
The recalled product
- Product
- Arrow Three-Lumen CVC
- Manufacturer
- ARROW INTERNATIONAL Inc.
- Affected units
- 10,301
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (20)
- Catalog Number: CV-12123-F
- Lot Numbers: 71F20A0430 [UDI: (01)20801902122838(17)211214(10)71F20A0430]
- 71F20A2583 [UDI: (01)20801902122838(17)250103(10)71F20A2583]
- 71F20B0793 [UDI: (01)20801902122838(17)250115(10)71F20B0793]
- 71F20B2188 [UDI: (01)20801902122838(17)250204(10)71F20B2188]
- 71F20C1356 [UDI: (01)10801902136944(17)220630(10)71F20C1356]
- 71F20D1047 [UDI: (01)20801902122838(17)250402(10)71F20D1047]
- 71F20E2225 [UDI: (01)20801902122838(17)250531(10)71F20E2225]
- 71F20G2376 [UDI: (01)20801902122838(17)250701(10)71F20G2376]
- 71F20K0771 [UDI: (01)20801902122838(17)241130(10)71F20K0771]
- 71F20K2265 [UDI: (01)20801902122838(17)250228(10)71F20K2265]
- 71F20L0567 [UDI: (01)20801902122838(17)250228(10)71F20L0567]
- 71F20M1262 [UDI: (01)20801902122838(17)250331(10)71F20M1262]
- 71F21B0849 [UDI: (01)10801902179514(17)250430(10)71F21B0849]
- 71F21B0850 [UDI: (01)20801902122838(17)250430(10)71F21B0850]
- 71F21B2430 [UDI: (01)20801902122838(17)250430(10)71F21B2430]
- 71F21C0637 [UDI: (01)20801902122838(17)250331(10)71F21C0637]
- 71F21C0964 [UDI: (01)10801902170856(17)260214(10)71F21C0964]
- 71F21D0025 [UDI: (01)20801902122838(17)250430(10)71F21D0025]
- 71F21E0586 [UDI: (01)20801902122838(17)250430(10)71F21E0586]
Distribution
Related recalls
Same manufacturer · ARROW INTERNATIONAL Inc.
See all →- HighArrow Arterial Kits Recalled Due to Open Packaging Seals
FDA (Devices) · 2024-10-02
- SevereIntra-Aortic Balloon Catheter Kit Recalled for Inflation and Structural Defects
FDA (Devices) · 2024-06-12
- SevereArrow UltraFlex Intra-Aortic Balloon Catheter Kit Recalled for Device Malfunction
FDA (Devices) · 2024-06-12
- SevereArrow Ultra 8 Intra-Aortic Balloon Catheter Kit Recalled for Inflation Defect
FDA (Devices) · 2024-06-12
- SevereARROW QuickFlash Radial Artery Catheters Recalled for Defective Component
FDA (Devices) · 2024-03-27
Similar recalls
- ModerateArrow Pediatric Central Venous Catheter Recalled for Incorrect Labeling
FDA (Devices) · 2019-01-23
- ModerateArrow International Recalls Two-Lumen CVC Kits Due to Labeling Error
FDA (Devices) · 2013-08-21
- ModerateArrow International Recalls Multi-Lumen Central Venous Catheter Sets
FDA (Devices) · 2018-07-11
- HighArrow Multi-Lumen CVC Kit Recalled by FDA for Medical Device Safety
FDA (Devices) · 2017-06-21
- SevereArrow Central Venous Catheter Recalled for Incorrect Lidstock Labeling
FDA (Devices) · 2023-10-11
- ModerateArrow Two-Lumen Central Venous Catheter Set Recalled for Labeling Error
FDA (Devices) · 2019-04-17