Elekta MOSAIQ Oncology Information System: Incorrect Image Offset Calculations
Elekta is recalling MOSAIQ Oncology Information System software that may produce incorrect image offsets for Linear Accelerators not characterized at IEC61217 scale.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: This is an FDA Class II medical device software error affecting radiation therapy systems. The potential for incorrect image offset calculations in cancer treatment represents a high-risk scenario. No reported injuries or illnesses are mentioned, classifying this as a risk-of-harm product without reported injury.
Plain-English summary
Elekta, Inc. is recalling the MOSAIQ Oncology Information System software due to image offsets calculated by the software that may be incorrect for Linear Accelerators (LINACs) not characterized according to the IEC61217 standard.
Affected software versions include 3.1.2.0 through 3.1.3.4 and 3.2.1.0 through 3.2.1.4. A total of 64 units are affected. The software has been distributed in the United States (Pennsylvania, Alabama, Florida, Iowa, and Utah) and internationally in Austria, Belgium, Bolivia, Bosnia and Herzegovina, Brazil, Canada, France, Germany, Hong Kong, Italy, Japan, Korea, Malta, Netherlands, Panama, South Africa, Spain, Taiwan, Thailand, Turkey, and Venezuela.
The recalled product
- Product
- MOSAIQ Oncology Information System
- Manufacturer
- Elekta, Inc.
- Affected units
- 64
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (10)
- Software versions /UDI: 3.1.2.0 (01)07340201500026 3.1.3.0 (01)07340201500026
- 3.1.3.1 (01)07340201500026
- 3.1.3.2 (01)07340201500026
- 3.1.3.3 (01)07340201500026
- 3.1.3.4 (01)07340201500026
- 3.2.1.0 (01)07340201500071
- 3.2.1.1 (01)07340201500071
- 3.2.1.2 (01)07340201500071
- 3.2.1.3 (01)07340201500071
- 3.2.1.4 (01)07340201500071
Distribution
Related recalls
Same manufacturer · Elekta, Inc.
See all →- SevereBrachytherapy Applicator Advanced Gynecological Applicator Tip Detachment
FDA (Devices) · 2026-07-15
- SevereFletcher CT/MR Shielded Applicator Set for Gynecological Brachytherapy Recalled
FDA (Devices) · 2026-07-15
- SevereElekta Geneva Brachytherapy Applicator Intrauterine Tube Detachment Risk
FDA (Devices) · 2026-07-15
- HighMOSAIQ oncology software may fail to load adapted treatment plan
FDA (Devices) · 2026-06-17
- HighLeksell Vantage Arc System locking mechanism may not secure properly
FDA (Devices) · 2026-05-06
Same hazard · calculation error
See all →- HighPinnacle 3 radiation planning software may miscalculate stopping power ratio
FDA (Devices) · 2025-08-13
- HighMedical Imaging Software Bug Affects Diagnostic Calculations on Daylight Saving Time Dates
FDA (Devices) · 2025-03-05
- HighRayStation radiation therapy software recall for density calculation inconsistency
FDA (Devices) · 2025-02-26
- HighSpine Surgery Planning Software Calculation Errors in Rod Planning Parameters
FDA (Devices) · 2025-02-12
- HighHorizon Cardiology Hemodynamic System Recalled for Configuration Error
FDA (Devices) · 2024-10-23
Similar recalls
- HighElekta Recalls MOSAIQ Oncology Software Due to Isocenter Copying Error
FDA (Devices) · 2019-01-02
- ModerateElekta MOSAIQ Oncology Software Recalled for Unit Labeling Error
FDA (Devices) · 2020-04-01
- ModerateElekta Recalls MOSAIQ Oncology Information System Software Due to Status Error
FDA (Devices) · 2018-08-29
- HighSiemens Medical Solutions Recalls Elekta MOSAIQ Software Due to Safety Risk
FDA (Devices) · 2013-04-17
- SevereElekta Recalls MOSAIQ Oncology System Due to Dosage Calculation Error
FDA (Devices) · 2016-01-06
- HighElekta Recalls MOSAIQ Oncology System Due to Potential Dosing Errors
FDA (Devices) · 2016-08-03