Smith & Nephew Recalls Reflection Dead Blow Mallets Due to Weld Cracks
Smith & Nephew is recalling Reflection Dead Blow Mallets because cracks in the weld allowed lead beads to escape into surgical wounds.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The recall is classified as FDA Class II and involves the release of lead particles into surgical wounds, which constitutes a significant injury risk and potential for serious harm.
Plain-English summary
Smith & Nephew, Inc. is recalling 4,444 units of the Reflection Dead Blow Mallet (REF 71362106). The recall was initiated after the firm received complaints regarding cracks in the weld on the head of the mallet.
In the reported cases, some of the lead beads and particles escaped from the mallet into the surgical wound. The affected units were distributed worldwide, including the United States (nationwide), Puerto Rico, and numerous international locations.
Healthcare facilities and consumers should stop using the affected mallets immediately. Users should check their inventory for the specific lot codes listed in the official recall notice and contact Smith & Nephew for instructions on return or replacement.
The recalled product
- Product
- REFLECTION(R) DEAD BLOW MALLET, REF 71362106, QTY: (1), NON-STERILE, Smith & Nephew, Inc,. Memphis, TN 38116
- Manufacturer
- Smith & Nephew, Inc.
- Affected units
- 4,444
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (20)
- 606861
- 606862
- 606863
- 606864
- 701432
- 701433
- 808421
- 808422
- 1200840
- 50903653
- 60708545
- 60806634
- 61005467
- 70704991
- 70907344
- 71002434
- 71106654
- 71106655
- 80603593
- 80603594
Distribution
Related recalls
Same manufacturer · Smith & Nephew, Inc.
See all →- HighTRIGEN proximal humeral nails are missing their distal holes
FDA (Devices) · 2026-06-24
- ModerateBone fixation screws recalled over a labeling error on one lot
FDA (Devices) · 2025-12-24
- ModerateSmith & Nephew Lag/Compression Screw Kit Undersized Socket Defect
FDA (Devices) · 2025-05-28
- HighBIORAPTOR Suture Anchors Recalled for Sterile Barrier Packaging Breach
FDA (Devices) · 2024-12-11
- HighSmith & Nephew Bipolar Hip Implant Component Recalled for Oversized Retainer Ring
FDA (Devices) · 2024-11-13
Same hazard · lead exposure
See all →- High
- High
- HighTheKiddoSpace Recalls Children's Handwriting Kits Over Lead Exposure
CPSC · 2026-02-26
- HighBASDEHEN Kitchen Faucets Recalled Due to Dangerous Lead Exposure
CPSC · 2025-05-29
- HighBracelet in Skechers Gift Sets Recalled for High Lead and Cadmium
CPSC · 2024-03-07
Similar recalls
- HighSmith & Nephew Recalls Reflection Interfit Shell Due to Undersized Radius
FDA (Devices) · 2014-03-05
- HighSmith & Nephew Recalls Reflection Acetabular Liners Due to Tolerance Issues
FDA (Devices) · 2014-01-01
- ModerateSmith & Nephew Recalls Spherical Head Reflection Cancellous Screws Due to Labeling Error
FDA (Devices) · 2016-08-03
- ModerateSmith & Nephew Recalls Renovation Thin Osteotome Blades Due to Shelf Life Concerns
FDA (Devices) · 2017-05-10
- HighSmith & Nephew Recalls PROFIX Mallets Due to Tip Detachment Risk
FDA (Devices) · 2019-12-25
- HighSmith & Nephew Recalls Rotation Medical Tendon Staples Due to Seal Defects
FDA (Devices) · 2024-09-18