Siemens Atellica CH Hemoglobin A1c Reagent Kits Recalled for Quality Control Issues
Siemens Healthcare is recalling Atellica CH Hemoglobin A1c reagent kits due to potential reagent carryover affecting quality control and patient test results. The issue may cause inaccurate diabetes monitoring measurements.
What this means for you
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: This is an FDA Class II recall involving potential reagent carryover in a diagnostic test reagent kit. While no illnesses or injuries are reported in the source, inaccurate hemoglobin A1c results could lead to improper diabetes management and represent a risk of harm to patients.
Plain-English summary
Siemens Healthcare Diagnostics, Inc. is recalling specific lots of the Atellica CH Enzymatic Hemoglobin A1c (A1c_E/A1c_H) reagent kit (Material Number 11097536). A total of 6,606 units have been distributed globally, including throughout the United States. The affected lot numbers are: 110027, 110060, 110065, 110091, 110113, 110129, 110137, 110161, 110170, 110208, 110224, 110234, 110235, 110262, 110265, 110273, 110286, 110315, 110330, 110347, and 110360.
Siemens Healthcare has identified a potential issue with reagent carryover in these kits. Reagent carryover can affect the accuracy of quality control results, patient test samples, and calibrator results. Hemoglobin A1c measurements are used to assess long-term blood glucose control in diabetes patients. Inaccurate results could lead to improper diabetes management decisions.
Clinical laboratories and healthcare facilities currently using these reagent kits should immediately discontinue use of the affected lot numbers. Facilities should contact Siemens Healthcare Diagnostics for instructions on returning affected kits and obtaining replacement reagents. Consider reviewing any test results obtained using these specific lot numbers, particularly for critical patient care decisions.
The recalled product
- Product
- Atellica CH Enzymatic Hemoglobin A1c (A1c_E/A1c_H), Siemens Material Number 11097536
- Manufacturer
- Siemens Healthcare Diagnostics, Inc.
- Affected units
- 6,606
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- UDI: 00630414220505
Distribution
Distributed nationwide across the United States.
Part of a larger recall action
This product is one of 4 recalled by Siemens Healthcare Diagnostics, Inc. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 4 products in this recall →Related recalls
Same manufacturer · Siemens Healthcare Diagnostics, Inc.
See all →- SevereSiemens Quinidine Assay Recalled for Precision Errors
FDA (Devices) · 2026-08-26
- SevereSiemens Recalls Emit 2000 Quinidine Assay Due to Precision Issues
FDA (Devices) · 2026-08-26
- LowSyva Emit Disopyramide Enzyme Immunoassay Calibrator Recalled for Sodium Azide Concentration
FDA (Devices) · 2026-08-12
- ModerateSiemens Tricyclic Antidepressant Calibrator/Controls Recall Lot U2
FDA (Devices) · 2026-08-12
- HighSiemens Atellica CH Urine Albumin In Vitro Diagnostic Recall
FDA (Devices) · 2026-08-12
Same hazard · reagent carryover
See all →- HighSiemens Atellica CH diagnostic reagent carryover may cause false laboratory test results
FDA (Devices) · 2023-09-06
- ModerateSiemens Atellica CH Total Protein II Recalled for Reagent Carryover
FDA (Devices) · 2023-09-06
- HighLaboratory diagnostic test may produce inaccurate results from reagent carryover
FDA (Devices) · 2023-09-06
- HighSiemens Atellica CH Analyzer: Reagent Carryover Affecting Magnesium Test Results
FDA (Devices) · 2023-09-06
- HighSiemens Atellica CH LDL Cholesterol analyzer reagent carryover issue
FDA (Devices) · 2023-09-06