Bio-Rad EVOLIS Microplate System Recalled for Plate Transport Hazard
Bio-Rad is recalling 278 EVOLIS Microplate Systems because a low fluid alarm could cause the plate transport to continue running, pushing plates off the transporter.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall is classified as FDA Class II. The hazard involves a mechanical failure that could cause injury, but the source text does not report any specific injuries or illnesses, fitting the 'High' severity criteria for risk-of-harm products where injury has not yet been reported.
Plain-English summary
Bio-Rad Laboratories, Inc. is recalling 278 units of the EVOLIS Microplate System, Catalog # 89601. The product is a 4-plate fully integrated microplate processing system designed for use with multiple EIA assays. The recall covers units distributed nationwide in the United States, including Puerto Rico.
The recall was initiated due to a mechanical hazard. When the system alarmed for a low "Washer Reagent Clean Fluid" level, customers opened the system drawer. In these instances, the plate transport mechanism was still running, which caused the plate to be pushed off the plate transporter. The instrument is not lot controlled, but each unit is assigned a unique serial number for traceability.
Customers should check their serial numbers against the list provided in the official recall notice. If the serial number matches, the device should be taken out of service and the customer should contact Bio-Rad Laboratories for instructions on repair or replacement.
The recalled product
- Product
- EVOLIS Microplate System, Catalog # 89601. Part number 89788 for the EVOLIS Operator's Manual. in vitro diagnostic Product Usage: EVOLIS Microplate System is a 4 plate fully integrated microplate processing system designed for use with multiple EIA assays.
- Manufacturer
- Bio-Rad Laboratories, Inc.
- Affected units
- 278
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (20)
- The EVOLIS Microplate System instrument is not lot controlled
- 9163700175
- 9163700187
- 9163700196
- 9163700208
- 9163700210
- 9163700231
- 9163700266
- 9163700278
- 9163700320
- 9163700328
- 9163700336
- 9163700337
- 9163700349
- 9163700354
- 9163700368
- 9163700402
- 9163700431
- 9163700449
- 9163700478
Distribution
Related recalls
Same manufacturer · Bio-Rad Laboratories, Inc.
See all →- HighToxoplasma IgM assay kits recalled over risk of false positive results
FDA (Devices) · 2025-09-10
- HighAPLS IgM Diagnostic Reagent Packs Recalled Due to Incorrect Conjugate
FDA (Devices) · 2023-05-17
- HighBioPlex 2200 Anti-CCP Reagent Pack Recalled for Reduced Diagnostic Specificity
FDA (Devices) · 2023-04-19
- HighBioPlex 2200 Anti-CCP Reagent Kit recalled due to reduced test specificity
FDA (Devices) · 2023-04-19
- HighCMV IgM EIA Diagnostic Test Recalled for Increased False Positives
FDA (Devices) · 2022-12-07
Same hazard · mechanical hazard
See all →- HighGE Optima XR200/220/240amx Radiographic System Column Safety Mechanism
FDA (Devices) · 2026-07-22
- HighHologic Mammography Systems Recalled for Unexpected C-Arm Movement
FDA (Devices) · 2023-03-01
- High
Similar recalls
- ModerateBio-Rad Recalls EVOLIS Microplate System Due to Software Error
FDA (Devices) · 2019-07-10
- LowBio-Rad Recalls FSE Image Upgrade Kits Due to Data Export Issues
FDA (Devices) · 2013-10-30
- ModerateBio-Rad Recalls MRSASelect In Vitro Diagnostic Plates Due to Abnormal Coloration
FDA (Devices) · 2019-06-12
- HighBio-Rad Recalls MRSASelect II Diagnostic Plates Due to Abnormal Coloration
FDA (Devices) · 2019-06-12
- HighPhilips MultiDiagnost-Eleva Imaging System Recalled for Missing Locking Plate
FDA (Devices) · 2019-04-03
- SevereTecan Hydroflex ELISA Plate Washer Recalled for Battery Overheating Risk
FDA (Devices) · 2016-08-31