Integra York Metzenbaum Scissors Recalled Due to Packaging Seal Separation
Integra York PA, Inc. is recalling 50 units of sterile Metzenbaum Scissors because packaging seals may separate, compromising sterility.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a risk-of-harm product (sterile surgical instruments) where the compromise of sterility poses a potential infection risk, but no injuries or illnesses have been reported in the source text.
Plain-English summary
Integra York PA, Inc. is recalling 50 units of Metzenbaum Scissors 7", Curved, Sterile. These single-use sterile surgical instruments are intended for cutting and grasping tissue in general surgical procedures. The recall is due to a defect in the packaging where the Chevron seals of the 6x10 Tyvek peel pouch may separate, causing the packages to open and compromising the sterility of the instruments.
The affected products are identified by Catalog # ST5-182 and lot # 355. The recall covers units distributed in North Carolina and Texas. No specific dates of distribution are provided in the source text.
Healthcare facilities and consumers should stop using the affected instruments and contact the recalling firm for instructions on return or replacement. The FDA has classified this as a Class II recall.
The recalled product
- Product
- Metzenbaum Scissors 7, Curved, Sterile The Metzenbaum Scissors 7, Curved Curved are single-use sterile surgical instruments intended for cutting and grasping tissue in general surgical procedures.
- Manufacturer
- Integra York PA, Inc
- Affected units
- 50
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (2)
- Catalog # ST5-182
- lot# 355
Distribution
Part of a larger recall action
This product is one of 2 recalled by Integra York PA, Inc under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 2 products in this recall →Related recalls
Same manufacturer · Integra York PA, Inc
See all →- HighIntegra York Recalls Sterile Rochester-Pean Hemostatic Forceps Due to Seal Defect
FDA (Devices) · 2016-12-21
- HighMiltex Chisel Blade Handle Recall Due to Insecure Blade Fit
FDA (Devices) · 2016-06-08
- ModerateIntegra Container Lids Recalled for Lack of FDA Clearance
FDA (Devices) · 2014-09-17
Same hazard · sterility compromise
See all →- ModerateAVID Medical Recalls Halyard IV Start Kits Due to Packaging Seal Issues
FDA (Devices) · 2026-09-30
- HighMedline Recalls Cataract Convenience Kits Due to Open Sterile Seals
FDA (Devices) · 2026-09-23
- HighMedline Myringotomy Kits Recalled for Potential Sterility Compromise
FDA (Devices) · 2026-09-23
- HighMedline Anesthesia Pain Kits Recalled for Potential Sterility Compromise
FDA (Devices) · 2026-09-23
- HighMaquet Percutaneous Insertion Kit Recalled for Sterile Barrier Integrity Issues
FDA (Devices) · 2026-09-23
Similar recalls
- ModerateStryker Metzenbaum Scissors Recalled Due to Sterilization Instructions
FDA (Devices) · 2014-12-24
- ModerateStryker Metzenbaum Scissors Recalled Due to Sterilization Instructions Error
FDA (Devices) · 2014-12-24
- ModerateStryker Endoscopy Recalls 5mm Metzenbaum Scissors Due to Sterilization Labeling Error
FDA (Devices) · 2014-12-24
- ModerateStryker Endoscopy Recalls Metzenbaum Scissors Due to Sterilization Instructions
FDA (Devices) · 2014-12-24
- LowStryker Laparoscopic Scissors Recalled Due to Sterilization Instructions Error
FDA (Devices) · 2014-12-24
- ModerateStryker Baby Metzenbaum Scissors Recalled Due to Sterilization Instructions
FDA (Devices) · 2014-12-24