B. Braun dispensing pins recalled for air filter leakage risk
B. Braun Medical is recalling dispensing pins with an elevated leakage risk in the air inlet filter. The leakage may reduce medication doses, delay treatment, or contaminate the fluid path, potentially causing bloodstream infection.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: This is an FDA Class II recall involving a medical device with potential for serious patient harm. The hazard—air inlet filter leakage—could reduce medication doses, delay treatment, and cause bloodstream infection through fluid contamination. No illnesses or injuries have been reported, placing this in the High severity category as a risk-of-harm product without reported injury.
Plain-English summary
B. Braun Medical, Inc. is recalling one lot of Dispensing Pins for Air Inlet Filter (Catalog No. 412005, DP2500) used to aspirate or inject medication and enteral feeding solution from inverted multi-dose vials. Lot number 0061788969 with expiration date 5/31/2026 is affected. The product was distributed nationwide in the United States and Canada.
The recalled dispensing pins may have an elevated risk of leakage from the air inlet filter. This leakage can result in decreased medication doses being delivered to patients, which may delay necessary treatment. Additionally, the leakage may contaminate the fluid pathway, potentially leading to bloodstream infection.
Healthcare facilities and providers in the affected distribution areas should identify and quarantine any dispensing pins from the recalled lot. Contact B. Braun Medical, Inc. for guidance on replacement or return of affected product. Do not use dispensing pins from the recalled lot.
The recalled product
- Product
- Dispensing Pins for Air Inlet Filter, Product Catalog No. 412005, DP2500 Dispensing Pin W/Valve. A valve for aspiration or injection of medication or enteral feeding solution from inverted multi-dose vials.
- Manufacturer
- B. Braun Medical, Inc.
Distribution
Related recalls
Same manufacturer · B. Braun Medical, Inc.
See all →- CriticalB. Braun Recalls Sodium Chloride Injection Due to Particulate Matter
FDA (Drugs) · 2026-09-16
- LowB Braun Recalls Discofix Stopcock Sets Due to Incorrect Expiration Date
FDA (Devices) · 2026-09-09
- SevereB. Braun Recalls Lactated Ringer's Injection Due to Particulate Matter
FDA (Drugs) · 2026-09-02
- ModerateB. Braun UPMC double catheter trays contain Mastisol with cracking tubing
FDA (Devices) · 2026-06-10
- ModerateB. Braun spinal epidural kits contain Mastisol with cracking tubing
FDA (Devices) · 2026-06-10
Same hazard · leakage
See all →- SevereDraeger VentStar Resus Neo Neonatal Breathing Circuit Recall
FDA (Devices) · 2026-10-07
- HighConvaTec Esteem Body Soft Convex Urostomy Pouches Recalled for Leakage
FDA (Devices) · 2026-08-26
- SevereStryker AHTO Tube Set Packaging Recalled for Handpiece Leaking
FDA (Devices) · 2026-08-12
- SevereMedtronic Perfusion Systems Recalls EOPA Elongated One-Piece Arterial Cannula Model 77522
FDA (Devices) · 2026-08-05
- HighICU Medical Recalls Hotline Fluid Warming Sets Due to Leakage Risk
FDA (Devices) · 2026-07-29
Similar recalls
- LowB. Braun Medical Recalls Non-Vented Dispensing Pins Due to Packaging Tears
FDA (Devices) · 2016-06-08
- LowB. Braun Recalls Non-Vented Dispensing Pins Due to Packaging Tears
FDA (Devices) · 2016-06-08
- HighInfusion Pump Sets Recalled for Leakage and Medication Under-Delivery Risk
FDA (Devices) · 2021-10-06
- HighB. Braun Recalls WHIN Infusion Sets Due to Needle Protrusion Risk
FDA (Devices) · 2016-06-01
- HighB. Braun Infusion Pump Sets Recalled for Leakage and Infection Risk
FDA (Devices) · 2021-10-06
- HighInfusion pump set backcheck valve malfunction may prevent medication delivery
FDA (Devices) · 2024-07-24