Bayer Recalls Medrad Source Administration Sets for Dosing Errors
Bayer Healthcare is recalling Medrad Source Administration Sets because tubing defects may cause incorrect dose positioning during nuclear medicine procedures.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall is classified as FDA Class II. The hazard involves potential dosing errors in medical procedures, which is a risk-of-harm product issue where specific injury reports are not detailed in the source text, fitting the 'High' severity criteria for risk-of-harm products without reported injury.
Plain-English summary
Bayer Healthcare is recalling Medrad Source Administration Sets (Catalog number INT CSS) used with MEDRAD Intego PET Infusion pump Systems. These devices are utilized in nuclear medicine diagnostic procedures.
The recall is due to an investigation finding that the inner diameter of the saline tubing is out of specification. This defect may cause the system to fail to position the dose correctly during extraction, potentially leading to a low measurement of the extracted dose or a higher dose being extracted. Additionally, occluded tubing may impair the priming function and prompt a prime fail error.
The affected units were distributed nationwide to specific states including AR, AZ, CA, CO, CT, FL, GA, HI, IA, ID, IL, IN, KS, LA, MA, MI, MN, MO, NC, NE, NH, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, VA, VT, and WI. Users should stop using the affected administration sets and contact Bayer Healthcare for further instructions.
The recalled product
- Product
- Medrad Source Administration Sets, Catalog number INT CSS. For use with MEDRAD Intego PET Infusion pump Systems, in nuclear medicine diagnostic procedures.
- Manufacturer
- Bayer Healthcare
- Affected units
- 198,598
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (20)
- 50856405
- 50857510
- 50860994
- 50866789
- 50867921
- 50869464
- 50869465
- 50871131
- 50872965
- 50878229
- 50878230
- 50878231
- 50878232
- 50881328
- 50881393
- 50881394
- 50881395
- 50881506
- 50881511
- 50881512
Distribution
Related recalls
Same manufacturer · Bayer Healthcare
See all →- HighBayer Recalls Medrad Intego PET Infusion System Pumps
FDA (Devices) · 2017-02-15
- HighBayer Medrad Intego PET Infusion Pump Recall for Pressure Testing Failure
FDA (Devices) · 2016-11-23
- SevereBayer Certegra Workstation Recalled for Fire and Smoke Risk
FDA (Devices) · 2016-09-14
- ModerateBayer Recalls MEDRAD MRXperion MRI Injection Systems Due to Error Messages
FDA (Devices) · 2016-07-27
- HighBayer Medrad Mark 7 Arterion Injection System Software Recall
FDA (Devices) · 2015-09-23
Same hazard · dosing error
See all →- SevereLevothyroxine Sodium Tablets Recalled for Subpotency
FDA (Drugs) · 2026-07-29
- SevereMajor Pharmaceuticals Recalls Levothyroxine Sodium Tablets Over Subpotency
FDA (Drugs) · 2026-07-29
- HighPhothera 200 phototherapy calibration certificates had outputs reversed
FDA (Devices) · 2026-06-10
- HighMedline eye trays contain insulin syringes labeled as tuberculin syringes
FDA (Devices) · 2026-06-03
- CriticalPediatric ALS organizers recalled over potentially harmful drug dosing errors
FDA (Food) · 2026-02-04
Similar recalls
- HighBayer Recalls Medrad Intego PET Infusion System Pumps
FDA (Devices) · 2017-02-15
- HighBayer Medrad Intego PET Infusion Pump Recall for Pressure Testing Failure
FDA (Devices) · 2016-11-23
- HighBayer Recalls Medrad Continuum MR Infusion System Tubing Sets
FDA (Devices) · 2012-12-26
- ModerateMedrad Continuum MR Infusion System tubing sets recalled for flow accuracy issues
FDA (Devices) · 2012-12-26
- HighSource Administration Set medical device recalled for contamination
FDA (Devices) · 2023-01-18
- HighBayer Recalls Medrad Continuum MR Infusion Pump Tubing Sets
FDA (Devices) · 2012-12-26