Zimmer Biomet Recalls Virage OCT Spinal Fixation System Due to Set Screw Defect
Zimmer Biomet is recalling the Virage OCT Spinal Fixation System because set screw staking is out of specification, which can interfere with rod insertion.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a high-risk medical device where a mechanical defect can interfere with the insertion of a spinal rod. No injuries or illnesses are reported in the source text, placing this in the 'risk-of-harm products where injury has not yet been reported' category.
Plain-English summary
Zimmer Biomet, Inc. is recalling the Virage OCT Spinal Fixation System, Item Number 07.01738.001. This posterior system is intended to achieve an implant and construct of the Occipital-Cervical-Thoracic spine (Occiput-T3). The recall involves 372 units distributed across 20 U.S. states and four countries: Australia, Germany, Switzerland, and Sweden.
The recall was initiated after product testing revealed that the staking of the set screw was out of specification. This defect can interfere with the insertion of the occipital rod when the set screw is staked too low. The affected lot numbers are 62968065, 62947660, 62536230, 62745662, 62773482, 62758613, and 62874869.
Healthcare providers and facilities should contact Zimmer Biomet to determine if they have affected units and to arrange for the appropriate corrective action.
The recalled product
- Product
- Zimmer, Virage OCT Spinal Fixation System, Item Number: 07.01738.001, a posterior system intended to achieve an implant and construct of the Occipital-Cervical-Thoracic spine (Occiput-T3). UDI Number 889024328952
- Manufacturer
- Zimmer Biomet, Inc.
- Category
- Medical Device — Spinal Fixation
- Affected units
- 372
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (7)
- Lots: 62968065
- 62947660
- 62536230
- 62745662
- 62773482
- 62758613
- 62874869
Distribution
Related recalls
Same manufacturer · Zimmer Biomet, Inc.
See all →- HighZimmer Biomet Recalls Spinal Rod Cutters Due to Fracture Risk
FDA (Devices) · 2020-12-30
- ModerateZimmer Biomet Recalls Polaris Spinal System Screws for Labeling Update
FDA (Devices) · 2020-12-23
- HighZimmer Biomet Recalls Hip Prosthesis Cups Due to Sterilant Biocompatibility Concerns
FDA (Devices) · 2020-11-11
- HighZimmer Biomet Recalls Hip Prosthesis Components Due to Sterilant Biocompatibility Concerns
FDA (Devices) · 2020-11-11
- HighZimmer Biomet Recalls Hip Prosthesis Component Due to Sterilant Concerns
FDA (Devices) · 2020-11-11
Same hazard · mechanical defect
See all →- HighMobile Digital Radiographic System Arm Drop Risk During Patient Exams
FDA (Devices) · 2026-07-22
- ModerateSurgical driver systems recalled over out of the box driver wobble
FDA (Devices) · 2025-09-03
- HighBeckman Coulter DxI 9000 Analyzer wash wheel mixer defect may prevent operation
FDA (Devices) · 2025-03-19
- SevereBaxter Spectrum IQ Infusion System may have missing motor mounting screws
FDA (Devices) · 2025-03-12
- HighVNS Therapy Generator May Stop Delivering Stimulation Due to Mechanical Defect
FDA (Devices) · 2025-02-12
Similar recalls
- ModerateVirage OCT Spinal Fixation System Recall for Updated Surgical Guidance
FDA (Devices) · 2016-03-09
- HighZimmer Biomet Recalls Altius M-INI OCT Spinal Fixation System
FDA (Devices) · 2017-04-05
- HighZimmer Biomet Recalls Vitality Spinal Fixation Set Screws
FDA (Devices) · 2019-03-06
- SevereZimmer Biomet Recalls Vital MIS Spinal Fixation Implants Due to Locking Issues
FDA (Devices) · 2020-06-10
- SevereZimmer Biomet Recalls Vital MIS Spinal Fixation Implants Due to Locking Failure
FDA (Devices) · 2020-06-10
- ModerateZimmer Biomet Recalls Lineum Translation Screws Due to Incorrect Length Marking
FDA (Devices) · 2019-06-12