DJO EMPOWR Knee System Recall: Incorrect Device in Packaging
Encore Medical is recalling 37 DJO surgical EMPOWR Porous Knee System SIZE 8 devices distributed nationwide because incorrect product components were packaged with certain units.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: This is an FDA Class II recall involving a medical device where incorrect packaging creates a risk-of-harm situation. Although no illnesses or injuries have been reported, the potential for serious complications from device mismatch meets the rubric criterion for 'risk-of-harm products where injury has not yet been reported.'
Plain-English summary
Encore Medical, LP is recalling 37 DJO surgical EMPOWR Porous Knee System devices due to incorrect product/device components within the packaging. The affected devices include Model 243-01-108 (Lot 277W1114) and Model 353-03-108 (Lot 213W1051), both SIZE 8 Left configurations. These devices were distributed nationwide throughout the United States and are intended for knee arthroplasty (total knee replacement) in eligible patients.
When incorrect surgical components are packaged with devices, healthcare providers may receive and potentially implant the wrong component, which could lead to surgical complications or additional procedures.
Healthcare facilities and patients who received affected units should verify the contents of their packages before use. Any person who believes they received an incorrect device should contact Encore Medical, LP immediately. Additional information is available through the FDA.
The recalled product
- Product
- DJO surgical EMPOWR Porous Knee System Empowr 3D Femur-Porous Coated SIZE 8 Left 3D MATRIX COATED REF 243-01-108 DJO surgical EMPOWR KNEE", PRESS FIT BP MINUS, 8L REF 353-03-108 For the treatment of patients who are candidates for knee arthroplasty per the Indication for…
- Manufacturer
- Encore Medical, LP
- Affected units
- 37
Distribution
Distributed nationwide across the United States.
Related recalls
Same manufacturer · Encore Medical, LP
See all →- ModerateEMPOWR 3D KNEE insertion instruments recalled for incorrect product size packaging
FDA (Devices) · 2026-07-15
- ModerateEMPOWR 3D Knee surgical device recalled due to packaging discrepancy
FDA (Devices) · 2026-07-15
- SevereKnee and Humeral Socket Implants Recalled for Incorrect Labeling
FDA (Devices) · 2026-03-04
- HighShoulder prosthesis humeral socket inserts recalled over incorrect implant labeling
FDA (Devices) · 2026-03-04
- SevereReverse Shoulder Prosthesis Implants Recalled Over Incorrect Labeling
FDA (Devices) · 2026-03-04
Same hazard · device mismatch
See all →- ModeratePrelude IDEAL 4F Hydrophilic Sheath Introducer contains incorrect 5F dilators
FDA (Devices) · 2025-04-02
- HighStryker neurosurgical device labeling mismatch: wrong instruments shipped
FDA (Devices) · 2025-01-29
- HighHip prosthesis components recalled for mislabeling with incorrect sizes and types
FDA (Devices) · 2021-06-23
- HighZimmer NexGen Knee System Recall Due to Unapproved Component Combinations
FDA (Devices) · 2013-08-28
- HighZimmer Recalls NexGen Knee Components Due to Unapproved Combinations
FDA (Devices) · 2013-08-28
Similar recalls
- ModerateEMPOWR 3D KNEE insertion instruments recalled for incorrect product size packaging
FDA (Devices) · 2026-07-15
- HighKnee Prosthesis Recall: Packaging Mixup May Cause Wrong Size Implantation
FDA (Devices) · 2021-07-28
- ModerateEMPOWR 3D Knee surgical device recalled due to packaging discrepancy
FDA (Devices) · 2026-07-15
- HighDJO Surgical EMPOWR 3D Knee Tibial Insert packaging may contain wrong implant size
FDA (Devices) · 2021-07-28
- HighDJO EMPOWR 3D Knee Tibial Insert Mispackaged—Risk of Wrong Implant
FDA (Devices) · 2022-06-15
- ModerateEMPOWR 3D Knee Tibial Insert Recalled for Wrong Product in Package
FDA (Devices) · 2025-01-01