Siemens ARTIS icono biplane recalled for movement control issues
Siemens Medical Solutions is recalling three ARTIS icono biplane units because they may not execute movement control commands as intended.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall is classified as Class II and involves a potential failure to execute movement control commands on a medical device. The source does not report any illnesses, injuries, or deaths.
Plain-English summary
Siemens Medical Solutions USA, Inc. is recalling three units of the ARTIS icono biplane, Model Number 11327600. The recall is due to a potential issue where the system may not execute movement control commands as intended and may display the message "Limited stand/table movement, SC."
The affected units were distributed nationwide in California, Kentucky, New York, and Texas. The specific units are identified by Serial Numbers 180361, 180569, and 180607, and are running Software Version VE50B.
Healthcare facilities should contact Siemens Medical Solutions USA, Inc. for instructions on how to address the issue with these specific units.
The recalled product
- Product
- ARTIS icono biplane. Model Number: 11327600.
- Manufacturer
- Siemens Medical Solutions USA, Inc
- Hazard
- Affected units
- 3
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (3)
- Model Number: 11327600. UDI-DI: 4056869063317. Serial Numbers: 180361
- 180569
- 180607. Software Version VE50B.
Distribution
Related recalls
Same manufacturer · Siemens Medical Solutions USA, Inc
See all →- HighSiemens ARTIS icono Ceiling Recalled for Movement Control Defect
FDA (Devices) · 2026-11-18
- SevereSiemens ARTIS icono floor recalled for movement control issues
FDA (Devices) · 2026-11-18
- ModerateSiemens ARTIS icono ceiling recalled for potential loss of X-ray functionality
FDA (Devices) · 2026-11-18
- ModerateSiemens ARTIS icono biplane recalled for potential loss of X-ray functionality
FDA (Devices) · 2026-11-18
- ModerateSiemens ARTIS pheno X-ray System Recalled for Potential Loss of Functionality
FDA (Devices) · 2026-11-18
Same hazard · malfunction
See all →- ModerateSiemens ARTIS pheno Medical Device Recalled for Movement Control Issues
FDA (Devices) · 2026-11-18
- ModerateTransMedics Recalls OCS Lung Mission Critical Plus Perfusion Sets
FDA (Devices) · 2026-11-18
- ModerateFerno-Washington Power F2 Powered Fastening System Recall for Firmware Issue
FDA (Devices) · 2026-10-21
- ModerateCriticare nGenuity Patient Monitor Recalled for Capnography Setup Error
FDA (Devices) · 2026-09-30
- HighFresenius BlueStar Hemodialysis Machines Recalled for Alarm Defects
FDA (Devices) · 2026-09-02
Similar recalls
- SevereSiemens ARTIS icono floor recalled for movement control issues
FDA (Devices) · 2026-11-18
- HighSiemens ARTIS icono Ceiling Recalled for Movement Control Defect
FDA (Devices) · 2026-11-18
- ModerateSiemens ARTIS icono biplane recalled for potential loss of X-ray functionality
FDA (Devices) · 2026-11-18
- ModerateSiemens ARTIS pheno Medical Device Recalled for Movement Control Issues
FDA (Devices) · 2026-11-18
- ModerateARTIS icono biplane medical imaging system detector lift malfunction
FDA (Devices) · 2026-07-08
- ModerateSiemens ARTIS icono ceiling recalled for potential loss of X-ray functionality
FDA (Devices) · 2026-11-18