The Recall Desk
Agency classClass IIOur severity:HighFDA (Devices)·Z-0364-2023·Announced 2022-12-14

Treadmill Magnetic Safety Tether May Fail to Stop During Fall

Full Vision Inc. TrackMaster treadmills with specific serial numbers have a circuit defect that may prevent the magnetic safety tether from stopping the treadmill during a fall.

The agency’s classification

FDA (Devices): Class II

Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.

This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work

What this means for you

Our assessment, not the agency’s: severity 3/5 (High).

Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.

Our severity reasoning: This is a risk-of-harm product classified as FDA Class II with a safety function defect, but no injuries have been reported. The emergency stop mechanism may fail during a fall scenario; however, actual harm has not yet occurred.

Plain-English summary

Full Vision Inc. is recalling 106 units of the TrackMaster TMX428 110V treadmill (Model #317-07926) due to a circuit defect affecting the magnetic safety tether.

A latch-up condition can occur in the circuit that controls the safety tether on the treadmill's control PCB. When the magnetic tether is pulled loose—such as during a fall—the treadmill may fail to stop.

Affected units were distributed to Wisconsin, Georgia, New York, and Mexico. Serial numbers range from FVDC-7585 through FVDC-7737. Owners of affected treadmills should contact Full Vision Inc. for further information.

The recalled product

Product
FULL VISION INC. TRACKMASTER, TREADMILL TMX428 110V, Model #317-07926
Manufacturer
Full Vision Inc
Affected units
106

Is your product affected?

Check your packaging against the codes below. If any of them match, the product is part of this recall.

Lot numbers (20)

  • UDI/DI 00860176000606
  • Serial Numbers: FVDC-7585
  • FVDC-7586
  • FVDC-7587
  • FVDC-7588
  • FVDC-7589
  • FVDC-7590
  • FVDC-7591
  • FVDC-7592
  • FVDC-7593
  • FVDC-7594
  • FVDC-7595
  • FVDC-7596
  • FVDC-7597
  • FVDC-7598
  • FVDC-7599
  • FVDC-7600
  • FVDC-7601
  • FVDC-7602
  • FVDC-7603

Distribution

Distributed in 3 states:

Part of a larger recall action

This product is one of 7 recalled by Full Vision Inc under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.

See all 7 products in this recall →

Same hazard · fail to stop

See all →