Vital Scientific Selectra ProM Analyzer Recalled for Power Supply Failure
Vital Scientific N.V. is recalling five Selectra ProM Analyzers due to power supply failures that cause instrument malfunction and prevent the production of patient results.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a medical device where a malfunction prevents the production of patient results, representing a risk of harm to patients due to lack of diagnostic data, but no specific injuries or illnesses are reported in the source text.
Plain-English summary
Vital Scientific N.V. is recalling five units of the Selectra ProM Analyzer, a clinical chemistry system intended for use in clinical laboratories. The affected instruments are identified by Catalog # 6003-435 (UDI # 03661540600395) and Catalog # 6003-436 (UDI # 03661540600401). The specific serial numbers for the recalled units are 11-7425, 11-7516, 11-7535, 11-7563, and 11-7564.
The recall was initiated because of a power supply failure. When this failure occurs, the instruments malfunction and no patient results are produced. This issue affects the reliability of the clinical chemistry system in generating necessary diagnostic data.
The affected instruments were distributed in the United States, specifically in the states of New York and Utah. Clinical laboratories should check their inventory for these specific serial numbers and contact Vital Scientific N.V. for further instructions on the recall.
The recalled product
- Product
- Selectra ProM Analyzer, Catalog # 6003-435/UDI # 03661540600395 and Catalog # 6003-436/UDI # 03661540600401 Product Usage: :clinical chemistry system intended for use in clinical laboratories.
- Manufacturer
- Vital Scientific N.V.
- Affected units
- 5
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (5)
- serial numbers: 11-7425
- 11-7516
- 11-7535
- 11-7563
- 11-7564.
Distribution
Part of a larger recall action
This product is one of 5 recalled by Vital Scientific N.V. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 5 products in this recall →Related recalls
Same manufacturer · Vital Scientific N.V.
See all →- HighV-Twin In Vitro Diagnostic Instruments Recalled for Sample Mismatch Risk
FDA (Devices) · 2019-12-04
- ModerateVital Scientific V-Twin Automated Chemistry Analyzer Recalled for Power Supply Failure
FDA (Devices) · 2019-10-23
- ModerateVital Scientific Viva-JR Automated Chemistry Analyzer Recalled for Power Supply Failure
FDA (Devices) · 2019-10-23
- ModerateVital Scientific Selectra ProS Analyzer Recalled for Power Supply Failure
FDA (Devices) · 2019-10-23
- ModerateVital Scientific Viva-E Automated Chemistry Analyzer Recalled for Power Supply Failure
FDA (Devices) · 2019-10-23
Same hazard · power supply failure
See all →- HighMedical Device Recall: BD FACSLyric Flow Cytometer Power Supply Failure Risk
FDA (Devices) · 2025-01-01
- HighGalaxy System bronchoscope power supply defect may injure lung tissue
FDA (Devices) · 2025-01-01
- HighBD FACSLyric Flow Cytometer Power Supply May Fail During Use
FDA (Devices) · 2025-01-01
- HighPhilips Patient Information Center iX UPS devices recalled for potential power failure
FDA (Devices) · 2024-05-01
- ModeratePrucka 3 Amplifier Power Supply May Fail and Cause Device Inoperability
FDA (Devices) · 2023-09-27
Similar recalls
- LowELITech Viva-ProE Systems Recalled for Software Malfunction
FDA (Devices) · 2019-10-09
- ModerateV-Twin Automated Chemistry Analyzer Recalled for Software Lockup
FDA (Devices) · 2019-10-02
- HighVital Scientific V-Twin Automated Chemistry Analyzer Recall for Cooling Defect
FDA (Devices) · 2019-10-16
- ModerateSiemens ADVIA Centaur Prolactin Assay Recalled for Analytical Sensitivity Failure
FDA (Devices) · 2012-09-26
- HighPhadia 1000 Instrument Recalled Due to Retry Command Malfunction
FDA (Devices) · 2018-01-24
- HighSteris Caviwave Pro Ultrasonic Cleaning System Recalled for Power Failure Risk
FDA (Devices) · 2015-05-06