Testosterone Injections Recalled for Lack of Sterility Assurance
Tailor Made Compounding is recalling 246 vials of compounded testosterone injections distributed nationwide due to lack of assurance of sterility. Non-sterile injectable medications may pose a risk of infection.
The agency’s classification
FDA (Drugs): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: This is an FDA Class II recall involving a risk-of-harm product (injectable medication) where lack of sterility assurance could lead to serious infections. No illnesses or injuries have been reported in the source material, placing it at the high-risk but non-severe threshold.
Plain-English summary
Tailor Made Compounding has initiated a recall of compounded testosterone injections (testosterone cypionate/enanthate/propionate 80/80/40mg) in both 5 mL and 10 mL vials due to lack of assurance of sterility. The recall affects 246 vials distributed nationwide, including Puerto Rico, across seven batches with expiration dates ranging from April to August 2022.
The lack of assurance of sterility means the products may not have been produced under proper conditions to ensure they are free from harmful microorganisms. Non-sterile injectable medications pose a risk of serious infections when injected.
Patients who have received these injections should contact their healthcare provider. Healthcare providers and patients should verify batch numbers (10202107A1, 10142120A2, 10272102A1, 11032117A2, 11102104A2, 01252212A2, 02182227A1) against the product they have. Any vials matching these batch numbers should not be used.
The recalled product
- Product
- Testosterone Cypionate/Enanthate/Propionate 80/80/40mg, a) 5 mL-vial, b) 10 ml-vial, Room temperature, Tailor Made Compounding
- Manufacturer
- TMC Acquisition LLC dba Tailor Made Compounding
- Affected units
- 246
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (13)
- Batch#: a) 10202107A1
- Exp 4/18/2022
- b) 10142120A2
- Exp 4/12/2022
- 10272102A1
- Exp 4/25/2022
- 11032117A2
- 11102104A2
- Exp 4/30/2022
- 01252212A2
- Exp 7/24/2022
- 02182227A1
- Exp 8/17/2022 .
Distribution
Part of a larger recall action
This product is one of 52 recalled by TMC Acquisition LLC dba Tailor Made Compounding under a single FDA (Drugs) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 52 products in this recall →Related recalls
Same manufacturer · TMC Acquisition LLC dba Tailor Made Compounding
See all →- HighDexpanthenol Preservative Free Injectable Recalled Due to Sterility Assurance Failure
FDA (Drugs) · 2022-07-20
- HighHydroxocobalamin Compounded Injections Recalled for Lack of Sterility Assurance
FDA (Drugs) · 2022-07-20
- HighTailor Made Compounding Recalls Glycyrrhizic Acid Injectable for Lack of Sterility Assurance
FDA (Drugs) · 2022-07-20
- HighFDA Recalls Tailor Made Compounding GAC Injectable Vials for Lack of Sterility Assurance
FDA (Drugs) · 2022-07-20
- HighEstradiol Cypionate Injectable Recalled for Lack of Sterility Assurance
FDA (Drugs) · 2022-07-20
Same hazard · lack of sterility
See all →- SevereK.C. Pharmaceuticals Recalls Dry Eye Relief Eye Drops for Sterility Concerns
FDA (Drugs) · 2026-10-14
- SevereK.C. Pharmaceuticals Recalls Multiple Brands of Eye Drops for Sterility Concerns
FDA (Drugs) · 2026-10-14
- SevereClear Eyes Redness Relief Eye Drops Recalled for Sterility Concerns
FDA (Drugs) · 2026-09-30
- SevereClear Eyes Redness Relief Eye Drops Recalled for Sterility Assurance Issues
FDA (Drugs) · 2026-09-30
- SevereGentle Eyes Lubricant Eye Drops Recalled for Sterility Concerns
FDA (Drugs) · 2026-09-30
Similar recalls
- SevereTestosterone Cypionate Injectable Recalled for Lack of Sterility Assurance
FDA (Drugs) · 2021-11-17
- High
- SevereTestosterone Cypionate Injection Recalled Due to Sterility Concerns
FDA (Drugs) · 2015-09-23
- SevereTestosterone Cypionate Injection Recalled for Lack of Sterility Assurance
FDA (Drugs) · 2015-09-23
- SevereTestosterone Cypionate Injectable Recalled Due to Sterility Concerns
FDA (Drugs) · 2013-06-12
- HighInjectable Testosterone Recalled for Lack of Sterility Assurance
FDA (Drugs) · 2022-06-01