The Recall Desk

Manufacturer

Stryker GmbH

75 recalls in our database name Stryker GmbH as the manufacturing or recalling firm.

What the numbers show

Total
75
Critical
0
Severe
19
Most recent
2026-08-05

Of the 75 recalls from Stryker GmbH we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 19 (25%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–25 of 75

  • HighFDA (Devices)·Z-2829-2026·2026-08-05

    Stryker Hoffmann II Connecting Rod Micro May Crack After Cleaning and Sterilization

    Stryker GmbH is recalling Stryker Hoffmann II Connecting Rod Micro 3 x 50mm due to a potential risk of the rods cracking after cleaning and sterilization.

    Product
    Stryker Hoffmann II Connecting Rod Micro 3 x 50mm. Catalog Number: 50796050.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2827-2026·2026-08-05

    Stryker Hoffmann II Connecting Rod Micro Recalled Due to Potential Cracking

    Stryker is recalling Hoffmann II Connecting Rod Micro 3 x 30mm (catalog 50796030) because the rods may crack after cleaning and sterilization. FDA has classified this as Class II.

    Product
    Stryker Hoffmann II Connecting Rod Micro 3 x 30mm. Catalog Number: 50796030.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2833-2026·2026-08-05

    Stryker Hoffmann II Connecting Rod Micro May Crack After Cleaning and Sterilization

    Stryker GmbH is recalling Stryker Hoffmann II Connecting Rod Micro 3 x 150mm due to the potential for the rods to crack following cleaning and sterilization processes.

    Product
    Stryker Hoffmann II Connecting Rod Micro 3 x 150mm. Catalog Number: 50796150.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2830-2026·2026-08-05

    Stryker Hoffmann II Carbon Connecting Rods Recalled Over Potential Cracking

    Stryker GmbH is recalling Hoffmann II Carbon Connecting Rods (catalog 50796060) because they may crack after cleaning and sterilization. The recall covers all lots and about 9,658 units distributed worldwide.

    Product
    Stryker Hoffmann II Connecting Rod Micro 3 x 60mm. Catalog Number: 50796060.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1939-2025·2025-06-18

    Femoral Nail T2 GTN Left and Right Versions Mislabeled

    Stryker GmbH is recalling certain Femoral Nail T2 GTN devices because some labeled as left version contained right nails, and vice versa. This mislabeling could result in incorrect surgical implantation.

    Product
    Femoral Nail, LEFT T2 GTN 8x300 mm. Catalog Number: 1850-0830S.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1914-2025·2025-06-18

    Stryker Gamma4 Long Nail with incorrect left-nail geometry recalled

    Stryker GmbH is recalling a specific lot of Gamma4 Right Long Nails (Catalog Number 84250320S) because they were manufactured with left-nail geometry instead of right-nail geometry, which could affect surgical fit and function.

    Product
    Long Nail, RIGHT Gamma4 10x320mm x 125, component of the Gamma4 System. Catalog Number: 84250320S.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1940-2025·2025-06-18

    Femoral Nail RIGHT T2 GTN 8x300 mm labeled incorrectly

    Stryker GmbH is recalling Femoral Nail RIGHT T2 GTN 8x300 mm devices because some lots were labeled as left or right but contained the opposite orientation.

    Product
    Femoral Nail, RIGHT T2 GTN 8x300 mm. Catalog Number: 1851-0830S.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1620-2025·2025-04-23

    Guide Wire with Ruler Tube 3x800 mm Metal Ring Detachment Recall

    Stryker GmbH is recalling the Guide Wire with Ruler Tube 3x800 mm DIA because the metal ring at the end may detach during surgery. The defect could interfere with the surgical procedure.

    Product
    Guide Wire with Ruler Tube 3x800 mm DIA; Catalog number/REF: 2351-3080S;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1621-2025·2025-04-23

    Guide Wire with Ruler Tube metal ring detachment recall

    Stryker GmbH is recalling Guide Wire with Ruler Tube 3x1000 mm DIA devices because the metal ring at the end may detach during surgery.

    Product
    Guide Wire with Ruler Tube 3x1000 mm DIA; Catalog number/REF: 2351-3100S;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2219-2024·2024-07-03

    Stryker Hoffman LRF Wire Tensioner Adjustment Ring May Become Loose

    Stryker is recalling 39 Hoffman LRF Wire Tensioner devices because the adjustment ring may loosen, preventing proper tension setting. No injuries reported.

    Product
    Stryker Hoffman LRF Wire Tensioner REF 4933-9-100, a component of the Hoffmann LRF System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1191-2023·2023-03-08

    Stryker Hoffmann LRF Transport Strut Locking Mechanism Recall

    Stryker is recalling Hoffmann LRF Transport Strut devices due to oversized thread pitch that prevents the distal ring fixation from locking, affecting 488 units nationwide.

    Product
    stryker Hoffmann LRF, Transport Strut, Model Number 4933-0-400; Orthopedic external fixation device intended to keep bone fragments/segments in a correct anatomical position until reliable bone consolidation is achieved
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1011-2022·2022-05-04

    Smart Toe II Surgical Implant Recalled: Obscured Nickel Warning Label

    Stryker GmbH recalls 246 Smart Toe II orthopedic implants due to label obstruction that obscures the nickel-sensitivity contraindication, potentially allowing inappropriate use.

    Product
    Smart Toe II Intramedullary Arthrodesis Implant
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2171-2021·2021-08-11

    Stryker Nail Insertion Sleeve Recalled for Inner Diameter Mismatch

    Stryker GmbH is recalling 242 Nail Insertion Sleeves (Catalog Number 18061406S, Lot K03CC4F) because the inner diameter does not match the dimension specified on the outer box label.

    Product
    Nail Insertion Sleeve, elastic T2 Tibia SPI ¿8-11 (SPI Elast. Sleeve 8-11), Catalog Number 18061406S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2170-2021·2021-08-11

    Stryker Nail Insertion Sleeve Recalled for Incorrect Inner Diameter

    Stryker is recalling Nail Insertion Sleeves with incorrect inner diameters that do not match the box label. The dimensional mismatch could affect proper fit during orthopedic surgical procedures.

    Product
    Nail Insertion Sleeve, elastic T2 Tibia SPI ¿8-13 (SPI Elast. Sleeve 8-13), Catalog Number 18061407S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0457-2021·2020-11-25

    Stryker Recalls Osteosynthesis Compression Staple EasyClip Devices

    Stryker GmbH is recalling EasyClip and EasyClip Xpress staples due to potential nickel release above safety margins in pediatric patients under 20 kg.

    Product
    Osteosynthesis Compression Staple EasyClip
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2382-2020·2020-06-24

    Stryker Locking Screw Recall Due to Potential Sterility Compromise

    Stryker is recalling specific lots of Locking Screws because the blister pack seal may be compromised, meaning sterility cannot be assured.

    Product
    Stryker Locking Screw, Fully Threaded T2 Tibia ¿5x35 mm Catalog Number: 18965035S - Product Usage: Stryker implants are single use devices intended for the temporary fixation, correction or stabilization of bones.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2383-2020·2020-06-24

    Stryker Locking Screw Recall Due to Compromised Blister Pack Seal Integrity

    Stryker is recalling specific lots of locking screws because the blister pack seal may be compromised, meaning sterility cannot be assured.

    Product
    Stryker Locking Screw, Fully Threaded T2 Tibia ¿5x37,5 mm Catalog Number: 18965037S - Product Usage: Stryker implants are single use devices intended for the temporary fixation, correction or stabilization of bones.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2376-2020·2020-06-24

    Stryker End Cap Recall Due to Potential Sterility Compromise

    Stryker GmbH is recalling specific End Cap implants because the blister pack seal may be compromised, meaning sterility cannot be assured.

    Product
    Stryker End Cap, Standard T2 Humerus ¿6 mm Catalog Number: 18300003S - Product Usage: Stryker implants are single use devices intended for the temporary fixation, correction or stabilization of bones.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2374-2020·2020-06-24

    Stryker Compression Screw Recalled Due to Potential Sterility Compromise

    Stryker GmbH is recalling specific Advanced T2 Tibia Compression Screws because the blister pack seal integrity may be compromised, meaning sterility cannot be assured.

    Product
    Stryker Compression Screw, Advanced T2 Tibia Catalog Number: 18220001S - Product Usage: Stryker implants are single use devices intended for the temporary fixation, correction or stabilization of bones.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2375-2020·2020-06-24

    Stryker End Cap T2 Tibia Recalled Due to Compromised Sterility

    Stryker GmbH is recalling specific lots of End Cap T2 Tibia implants because the blister pack seal may be compromised, meaning sterility cannot be assured.

    Product
    Stryker End Cap T2 Tibia +10 mm Catalog Number: 18220010S - Product Usage: Stryker implants are single use devices intended for the temporary fixation, correction or stabilization of bones.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2373-2020·2020-06-24

    Stryker Locking Screw Recall Due to Compromised Sterility

    Stryker is recalling specific locking screws because the packaging seal may be compromised, meaning sterility cannot be assured.

    Product
    Stryker Locking Screw, Fully Threaded S2 05x35 mm Catalog Number: 17965035S - Product Usage: Stryker implants are single use devices intended for the temporary fixation, correction or stabilization of bones.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2384-2020·2020-06-24

    Stryker Locking Screw Recall Due to Compromised Blister Pack Seal Integrity

    Stryker GmbH is recalling specific lots of Locking Screws because the blister pack seal may be compromised, meaning sterility cannot be assured.

    Product
    Stryker Locking Screw, Fully Threaded T2 Tibia ¿5x40 mm Catalog Number: 18965040S - Product Usage: Stryker implants are single use devices intended for the temporary fixation, correction or stabilization of bones.
    Category
    Medical Device
    Distribution
    Distributed nationwide