The Recall Desk

Manufacturer

MEDLINE INDUSTRIES, LP - Northfield

822 recalls in our database name MEDLINE INDUSTRIES, LP - Northfield as the manufacturing or recalling firm.

What the numbers show

Total
822
Critical
9
Severe
68
Most recent
2025-10-01

Of the 822 recalls from MEDLINE INDUSTRIES, LP - Northfield we have scored against our rubric, 9 (1%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 68 (8%) are Severe.

Which agencies issued them

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

776–800 of 822

  • HighFDA (Devices)·Z-1047-2023·2023-02-08

    Medline UNITE Foot & Ankle Drill Bit Recalled for Intra-operative Screw Failure Risk

    Medline Industries recalls 190 UNITE foot and ankle drill bits due to observed screw failure during surgery. When used to pre-drill holes for certain screw sizes, the drill bits may fail under surgical torque, creating risk during procedures.

    Product
    MEDLINE UNITE FOOT & ANKLE DRILL BIT, 1.3MM Solid Core, REF MPN10013
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1030-2023·2023-02-08

    Non-sterile procedural trays risk sterile packaging breach

    Medline Industries is recalling non-sterile laparoscopic procedural trays containing sterile blades that may puncture the outer packaging, potentially breaching the sterile barrier. 260 cases have been distributed nationwide.

    Product
    Non-sterile procedural trays labeled as LAPAROSCOPIC, 2 per case
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1029-2023·2023-02-08

    MEDLINE procedural trays recalled for potential sterile packaging breach

    MEDLINE is recalling procedural trays because sterile blades within the kits could puncture the outer foil packaging, potentially breaching the sterile barrier.

    Product
    Non-sterile procedural trays labeled as CRANI, 2 per case
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1015-2023·2023-02-01

    Medical Device Manufacturer Recalls VAD Drive Kits With Expired Component

    Medline Industries is recalling 1,050 kits of Centurion Medical Products Silver Antimicrobial VAD Drive due to expired components. Affected kits were distributed across New York, Indiana, Florida, New Jersey, and Illinois.

    Product
    CENTURION MEDICAL PRODUCTS, SILVER ANTIMICROBIAL VAD DRIVE, REF DT18760
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0930-2023·2023-01-18

    Medline CISION Sterile Surgical Blades Recalled for Sterile Packaging Breach Risk

    Medline Industries is recalling CISION Sterile Blades used in surgical procedures due to potential for the blade to puncture the sterile outer packaging, breaching sterility. No injuries reported.

    Product
    Medline CISION Sterile Blades. Labeled as follows with corresponding Item Number. a. STERILE BLADE NO. 10 CARBON STEEL, Item Number: CISION10CS; b. STERILE BLADE NO. 10 CARBON STEEL RIB, Item Number: CISION10CSR; c. STERILE BLADE NO. 11 CARBON STEEL, Item Number…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0158-2023·2022-11-09

    Surgical Cataract Pack Recalled Due to Compromised Sterile Packaging

    Medline Industries is recalling 300 units of Bausch + Lomb Cataract Packs due to breather pouches with seal openings that may compromise sterility. The affected surgical kits were distributed nationwide.

    Product
    BAUSCH + LOMB CATARACT PACK, REF VAL009CTSGA. Convenience kit used in surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0157-2023·2022-11-09

    Bausch + Lomb Ophthalmic Surgical Kits Recalled for Sterile Packaging Defect

    Medline Industries is recalling 800 Bausch + Lomb Basic Ophthalmic surgical kits (Lot 22DBN365) for defective breather pouch seals. Opened seals in the packaging compromise the sterile conditions required for surgical procedures.

    Product
    BAUSCH + LOMB BASIC OPHTHALMIC PACK, REF LYN023BSBLB. Convenience kit used in surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0156-2023·2022-11-09

    Surgical Kit Sterile Pouches with Seal Openings Recalled by Medline

    Medline is recalling approximately 160 surgical kits with defective breather pouches showing seal openings, potentially compromising sterility. The recall affects facilities in eight states nationwide.

    Product
    BAUSCH + LOMB PHACO PACK, REF LYN011PHNHD. Convenience kit used in surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0167-2023·2022-11-09

    NICU PICC Insertion Bundle Recalled for Breather Pouch Seal Defects

    Medline Industries recalls NICU PICC insertion bundles (50 kits) due to openings in breather pouch seals that compromise sterile barrier integrity. This Class II recall affects units distributed across the United States.

    Product
    CENTURION MEDICAL PRODUCTS NICU PICC INSERTION BUNDLE W/O, REF CVI4470. Convenience kit used in medical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0163-2023·2022-11-09

    Medline LINQ Surgical Trays Recalled for Compromised Pouch Seals

    Medline has recalled LINQ TRAY surgical kits with breather pouch seal openings that could compromise sterility. The recall affects 40 kits distributed nationwide; no injuries have been reported.

    Product
    MEDLINE LINQ TRAY, REF DYNJ65880A. Convenience kit used in medical/surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0160-2023·2022-11-09

    Surgical Cataract Kits Recalled for Defective Breather Pouch Seals

    Medline has recalled Bausch + Lomb cataract surgical kits due to breather pouches with seal openings that could compromise sterility. Affected kits were distributed nationwide.

    Product
    BAUSCH + LOMB CATARACT TRAY, REF LYN023FACTB. Convenience kit used in surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0159-2023·2022-11-09

    Surgical eye kits recalled for breached sterile pouches

    Medline Industries recalls Bausch + Lomb eye muscle surgical kits due to breached breather pouches that may compromise sterility. The affected kits (Lot 22DBN366) were distributed nationwide.

    Product
    BAUSCH + LOMB EYE MUSCLE, REF VAL036EMESB. Convenience kit used in surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0161-2023·2022-11-09

    Surgical Cataract Packs with Compromised Breather Pouch Seals Recalled

    Medline recalls 708 Bausch + Lomb cataract surgical packs due to breather pouch seal defects that could compromise sterility of surgical instruments.

    Product
    BAUSCH + LOMB CATARACT PACK, REF VAL001CPMEA. Convenience kit used in surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0164-2023·2022-11-09

    Medline Dental Pack Recall Due to Breather Pouch Seal Defect

    Medline is recalling Dental Pack surgical kits (Lot 22DBE139) because breather pouches have openings in their seals that could compromise sterility. Affected units were distributed to healthcare facilities in eight US states.

    Product
    MEDLINE DENTAL PACK, REF DYNJ66983. Convenience kit used in medical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0155-2023·2022-11-09

    Surgical Eye Kit Pouches Recalled for Seal Defects

    Medline recalls Bausch + Lomb Eye surgical kits due to breather pouches with openings in the seal. Affected kits were distributed to healthcare facilities nationwide; unopened kits should not be used.

    Product
    BAUSCH + LOMB EYE PACK, REF LYN003EYSPA. Convenience kit used in surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0166-2023·2022-11-09

    Medline CVC Barrier Kit Recalled for Breached Pouch Seals

    Medline is recalling CVC barrier kits (Lot 22ABT774) due to breather pouches with seal openings that could compromise sterility of the surgical kit contents.

    Product
    MEDLINE CVC BARRIER KIT, REF DYNJ80485. Convenience kit used in medical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0165-2023·2022-11-09

    Medline Radiology Procedure Pack Breather Pouches Recalled for Seal Defects

    Medline is recalling 240 Radiology Procedure Packs because some breather pouches show seal openings that could compromise sterility. The affected kits were distributed nationwide.

    Product
    MEDLINE RADIOLOGY PROCEDURE PACK, REF DYNJ67150A. Convenience kit used in medical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0162-2023·2022-11-09

    Medline Lithotomy Sterile Surgical Kit Recalled for Compromised Breather Pouch Seal

    Medline is recalling 96 sterile surgical kits (REF DYNJ50099C, Lot 22DBL482) distributed nationwide due to complaints of openings in breather pouches that compromise sterility and increase contamination risk.

    Product
    MEDLINE LITHOTOMY, REF DYNJ50099C. Convenience kit used in medical/surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0124-2023·2022-11-02

    Medline Pre-Op CHG Bathing Kit recalled for incorrect expiration dates

    Medline is recalling 460 Pre-Op CHG Bathing Kits because the CHG solution and blood culture bottles have expiration dates that don't match the kit label. Expired components could compromise effectiveness.

    Product
    MEDLINE PRE-OP CHG BATHING KIT Reorder #: P164756
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0122-2023·2022-11-02

    Medline Blood Culture Kits recalled due to mismatched component expiration dates

    Medline Industries is recalling 1,600 blood culture kits (Reorder # DYNDH1592) because component expiration dates don't match the kit label. Affected components include CHG Solution and Bactec bottle plastic.

    Product
    MEDLINE BLOOD CLUTURE KIT, Reorder #: DYNDH1592
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0121-2023·2022-11-02

    Medline Peripheral Blood Culture Draw Kit Recall: Incorrect Expiration Dates

    Medline is recalling 1,020 peripheral blood culture draw kits due to incorrect expiration dates on kit components. The CHG solution and Bactec bottle plastic have expiration dates that do not match the date listed on the kit.

    Product
    MEDLINE PHERIPHERAL BLOOD CULTURE DRAW, Reorder #: DYNDH1561
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0120-2023·2022-11-02

    Medline Blood Culture Collection Kits Recalled for Incorrect Expiration Dates

    Medline recalls Adult Blood Culture Collection Kits due to incorrect expiration dates on kit components. The expiration dates on the CHG Solution and Bactec bottle plastic do not match the dates listed on the kit packaging.

    Product
    MEDLINE ADLT BLOOD CLUTURE COLLECT KIT, Reorder #: DYNDH1245
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0123-2023·2022-11-02

    Blood Culture Collection Kit Distributed with Mismatched Component Expiration Dates

    Medline is recalling 760 blood culture kits because the expiration dates printed on the kit do not match the expiration dates on the CHG Solution and Bactec bottle components inside.

    Product
    MEDLINE 24 BLOOD CLUTURE KIT, Reorder #: DYNDH1632
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0106-2023·2022-10-26

    Chest Tube Insertion Tray Recalled Due to Over-Sterilization of Suture Component

    Medline recalls CENTURION SnagFree Chest Tube insertion trays because a silk suture component was sterilized twice instead of once, potentially compromising its integrity. The affected lot contains 18 kits distributed in California and Texas.

    Product
    CENTURION SnagFree Chest Tube insertion Tray, Reorder CHT545
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0088-2023·2022-10-19

    Medline Venclose cardiovascular procedure kits recalled for wrong component size

    Medline Industries is recalling 1,760 Venclose procedure packs due to incorrect introducer/sheath component size. Affected kits contain 12cm components instead of the required 7cm.

    Product
    VENCLOSE, VENCLOSE PROCEDURE PACK, 7VM, REF VC-PPH-67A. Cardiovascular procedure convenience kit.
    Category
    Medical Device
    Distribution
    1 state