The Recall Desk

Hazard

Structural Failure recalls

2,056 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
2,056
Critical
10
Severe
1,049
Most recent
2026-09-17

Of the 2,056 structural failure recalls we have scored against our rubric, 10 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,049 (51%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all structural failure recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1251–1275 of 2056

  • HighNHTSA·15V035000·2015-01-27

    Crossroads Recalls 2015 Z1 Trailers Due to Incorrect Ramp Load Labels

    Crossroads RV is recalling 2015 Z1 toyhauler trailers because the front loading ramps display a 700-pound capacity limit, but the actual limit is 500 pounds.

    Product
    CROSSROADS — CROSSROADS Z1
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V024000·2015-01-22

    Life Line Recalls Ford F-Series Emergency Vehicles with Suspension Defect

    Life Line Emergency Vehicles is recalling 2014-2015 Ford F-450 and F-550 SD emergency vehicles equipped with Liquid Spring suspension kits due to a potential mounting bracket failure.

    Product
    FORD — FORD F-450 SD, F-550 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·15063·2015-01-22

    Primal Vantage Recalls Ameristep Hyde Tree Stands Due to Fall Hazard

    Primal Vantage is recalling about 1,000 Ameristep Hyde tree stands because the aluminum platform can break, posing a fall risk to hunters.

    Product
    Ameristep Hyde Cliff Hanger and Sky Walker Tree Stands
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0953-2015·2015-01-21

    DePuy ATTUNE INTUITION Impaction Handle Recalled for Fracture Risk

    DePuy Orthopaedics is recalling ATTUNE INTUITION Impaction Handles because the lever can fracture during knee surgery, potentially leaving device pieces in the patient.

    Product
    The ATTUNE INTUITION Impaction Handle is a re-useable instrument utilized in knee replacement procedures. The instrument interfaces with several related ATTUNE instruments: keel punch, tibial tower, evaluation bullet, fixed bearing tibial impactor, rotating platform tibial impact
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0954-2015·2015-01-21

    GE Healthcare Proteus XR/a Wall Stand Cable Breakage Recall

    GE Healthcare is recalling Proteus XR/a X-ray systems with wall stands due to potential breakage of steel support cables. No injuries have been reported.

    Product
    GE Healthcare, Proteus XR/a with wall stand model number 600-0301.
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-0977-2015·2015-01-21

    SpineFrontier Recalls Inline Persuader Pedicle Screw System Due to Handle Crack

    SpineFrontier, Inc. is recalling four Inline Persuader PedFuse Pedicle Screw Systems because a crack may develop in the handle, potentially progressing with continued use.

    Product
    lnline Persuader- PedFuse Pedicle Screw System; Part Number: 11-80164
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0857-2015·2014-12-31

    Iris Diagnostics Recalls RTH8 Rotor for StatSpin Express 4 Centrifuge

    Iris Diagnostics is recalling RTH8 rotors for the StatSpin Express 4 Horizontal Centrifuge because the parts may develop cracks with use over time.

    Product
    RTH8 Rotor, P/N X01-005847-001. RTH8 used in the StatSpin Express 4 Horizontal Centrifuge, Model M510, Product No. SSH4. The RTH8 rotor is used with the Statspin Express 4 Horizontal Centrifuge. StatSpin Express 4 Centrifuge: For in vitro diagnostic use to produce the rapid s
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V826000·2014-12-30

    Dodgen Recalls 2014-2015 RVs for Suspension Tank Bracket Failure Risk

    Dodgen is recalling 2014-2015 Born Free RVs equipped with Liquid Spring suspension kits because a mounting bracket may fail, causing the fluid tank to separate and create a road hazard.

    Product
    DODGEN — DODGEN BORN FREE, BORN FREE MOBILITY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·14V825000·2014-12-29

    Dodgen Recalls Mobility RVs Due to Wheelchair Lift Platform Cracking Risk

    Dodgen is recalling 2006-2014 Mobile Tech. Mobility RVs equipped with specific Ricon wheelchair lifts because the platform side plate may crack, posing an injury risk.

    Product
    DODGEN — DODGEN MOBILE TECH. MOBILITY RV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V819000·2014-12-24

    GM Recalls 2015 Silverado and Sierra Trucks for Rear Axle Fracture Risk

    General Motors is recalling specific 2015 Chevrolet Silverado 1500 and GMC Sierra 1500 trucks because the rear axle shaft may fracture, potentially causing the rear wheel to separate.

    Product
    GMC — GMC, CHEVROLET SIERRA, SILVERADO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0800-2015·2014-12-24

    Carestream DRX-Revolution Mobile X-Ray System Recalled for Broken Bolts

    Carestream Health is recalling 629 DRX-Revolution Mobile X-Ray Systems because bolts securing the x-ray tube assembly may break, posing a risk of equipment failure.

    Product
    DRX-Revolution Mobile X-Ray System, MODEL DRXR-1, Service Code 1243, Catalog Number 1060177 (China) and 1019397 (all other countries) --- Carestream Health, Inc. The DRX-Revolution Mobile X-Ray System is a mobile imaging system that incorporates a self contained x-ray generat
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·14V799000·2014-12-17

    Winnebago WFG38S Recalled for Wheelchair Lift Platform Cracking Risk

    Farber Specialty Vehicles is recalling 2005-2008 Winnebago WFG38S vehicles with specific Ricon wheelchair lifts because the platform side plate may crack, posing an injury risk.

    Product
    WINNEBAGO — WINNEBAGO WFG38S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·15045·2014-12-12

    UVEX Recalls Bicycle Helmets Due to Chinstrap Anchor Failure Risk

    UVEX Sports is recalling 46,800 bicycle helmets because the chinstrap anchor can fail, causing the helmet to slide off and posing a head injury hazard.

    Product
    UVEX Bicycle Helmets
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V786000·2014-12-10

    Ameritrans Recalls Transit Buses Due to Suspension Tank Mount Failure Risk

    Ameritrans is recalling 2013-2014 F330 and 2013 R330 transit buses because a suspension fluid tank mount may fail, causing the tank to separate and create a road hazard.

    Product
    AMERITRANS — AMERITRANS F330, R330
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·15046·2014-12-10

    GCI Outdoor Recalls Stadium Seats Due to Backrest Failure Risk

    GCI Outdoor is recalling about 6,000 BleacherBack stadium seats because the backrest can fail, posing a risk of injury. Consumers should stop using the seats and contact the company for a repair kit.

    Product
    Stadium seats
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·14V780000·2014-12-08

    Kingmor Recalls IC CE School Buses with Cracking Wheelchair Lifts

    Kingmor is recalling 2006-2014 IC CE school buses equipped with certain Ricon wheelchair lifts because the platform side plates may crack, posing an injury risk.

    Product
    IC — IC CE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·15041·2014-12-04

    Salsa Cycles Recalls Bearpaw Bicycle Forks Due to Fall Hazard

    Salsa Cycles is recalling approximately 2,500 Bearpaw bicycle forks because they may bend or break, posing a fall hazard to riders.

    Product
    Salsa Bearpaw Bicycle Forks
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0468-2015·2014-12-03

    Summit J700 X-Ray Tube Stand Recalled for Insufficient Welds

    Summit Industries is recalling 32 J700 Floor Mounted Tube Stands because insufficient welds may cause breakage, leading to equipment damage or injury.

    Product
    The J700 Floor Mounted Tube Stand (FMTS) is intended to support and position the diagnostic x-ray tube housing assembly for a medical radiographic procedure. The product consists of a vertical column (with counterbalanced vertical carriage, counterweight and pulley system), horiz
    Category
    Medical Device
    Distribution
    14 states