The Recall Desk

Hazard

Quench recalls

22 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
22
Critical
20
Severe
0
Most recent
2026-01-21

Of the 22 quench recalls we have scored against our rubric, 20 (91%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all quench recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–22 of 22

  • HighFDA (Devices)·Z-1018-2026·2026-01-21

    MRI systems recalled over ice that may block magnet venting

    Canon Medical Systems is recalling 22 Vantage Titan 3T MRI systems because ice in the magnet venting system could lead to a helium vessel rupture during a quench.

    Product
    VANTAGE TITAN 3T Model MRT-3010/MEXL-3010
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1071-2026·2026-01-21

    MRI systems recalled over ice that may block the magnet venting system

    Canon Medical Systems is recalling 34 Vantage Galan 3T MRI systems because ice may form in the venting system, and a quench in that condition could rupture the helium vessel.

    Product
    Allura Xper FD20 Biplane; Model Number: 722013;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0431-2026·2025-11-19

    MRI upgrade recalled over ice blockage in helium venting paths

    Siemens Medical Solutions is recalling four MAGNETOM Cima.X Upgrade systems because an ice blockage may form in the magnet's helium venting paths. The FDA has classified it Class I.

    Product
    MAGNETOM Cima.X Upgrade. Model Number: 11689304.
    Category
    Medical Device
    Distribution
    1 state
  • CriticalFDA (Devices)·Z-0163-2026·2025-11-05

    MRI operating suites recalled over ice blockage in the magnet venting system

    IMRIS is recalling the IMRIS iMRI 3T V Operating Suite because an ice blockage in the Siemens 3 Tesla magnet's venting system could rupture the helium containment system during a quench. The FDA classified it Class I.

    Product
    IMRIS Operating Suite, IMRIS iMRI 3T V, containing Siemens 3 Tesla MRI Magnet, vIDA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0161-2026·2025-11-05

    Neuro operating suites recalled over ice blockage in magnet venting paths

    IMRIS is recalling the Neuro III-SV iMRI and iMRX systems because an ice blockage in the Siemens 3 Tesla Verio magnet's venting system could rupture the helium containment system during a quench.

    Product
    IMRIS Operating Suite, Neuro III-SV iMRI System, iMRX System, containing Siemens 3 Tesla MRI Magnet, Verio
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0164-2026·2025-11-05

    InVision operating suite recalled over ice blockage in magnet venting paths

    IMRIS is recalling the InVision 3T Operating Suite because an ice blockage in the Siemens 3 Tesla Vida magnet's venting system could rupture the helium containment system during a quench.

    Product
    IMRIS Operating Suite, InVision 3T Operating Suite, containing Siemens 3 Tesla MRI Magnet, Vida
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0162-2026·2025-11-05

    MRI operating suites with Skyra magnet recalled over venting system blockage

    IMRIS is recalling the IMRIS iMRI 3T S Operating Suite because an ice blockage in the Siemens 3 Tesla Skyra magnet's venting system could rupture the helium containment system during a quench.

    Product
    IMRIS Operating Suite, iMRI 3T S, containing Siemens 3 Tesla MRI Magnet, Skyra
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2663-2025·2025-10-08

    MAGNETOM Spectra MRI systems recalled over helium venting ice blockage

    Siemens is recalling three MAGNETOM Spectra MRI systems because an ice blockage in the magnet venting system could prevent helium escaping during a quench.

    Product
    MAGNETOM Spectra as the following: 1. MAGNETOM Spectra. Model Number: 10837643. 2. MAGNETOM Spectra (CN). Model Number: 10655588.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2657-2025·2025-10-08

    MRI scanner recalled over ice blockage in magnet helium venting system

    A MAGNETOM Connectom.X MRI system is being recalled because an ice blockage in the magnet venting system could prevent helium from escaping during a quench.

    Product
    MAGNETOM Connectom.X. Model Number: 11371480.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2654-2025·2025-10-08

    Biograph mMR scanners recalled over ice blockage in magnet venting

    Siemens is recalling 27 Biograph mMR systems because an ice blockage in the magnet venting system could stop helium escaping during a quench.

    Product
    Biograph mMR. Model Number: 10433372.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2661-2025·2025-10-08

    MAGNETOM Skyra fit MRI systems recalled over magnet vent ice blockage

    Siemens is recalling 56 MAGNETOM Skyra fit MRI systems because an ice blockage in the magnet venting system could stop helium escaping during a quench.

    Product
    MAGNETOM Skyra fit. Model Number: 10849580.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2660-2025·2025-10-08

    MAGNETOM Skyra MRI systems recalled over ice blockage in venting system

    Siemens is recalling 586 MAGNETOM Skyra (DE) MRI systems because an ice blockage in the magnet venting system could prevent helium escaping during a quench.

    Product
    MAGNETOM Skyra (DE). Model Number: 10432915. 510(k) Numbers: K101347, K111242, K123510, K133435, K140253, K141977, K142515, K153343, K173592, K202014, K231560.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2664-2025·2025-10-08

    MAGNETOM Verio MRI systems recalled over magnet venting ice blockage risk

    Siemens is recalling 154 MAGNETOM Verio MRI systems because an ice blockage in the magnet venting system could stop helium escaping during a quench.

    Product
    MAGNETOM Verio. Model Number: 10276755.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2658-2025·2025-10-08

    MAGNETOM Lumina MRI systems recalled over helium venting ice blockage risk

    Siemens is recalling 130 MAGNETOM Lumina (DE) MRI systems because an ice blockage in the magnet venting system could prevent helium escaping during a quench.

    Product
    MAGNETOM Lumina (DE). Model Number: 11344916.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2655-2025·2025-10-08

    BIOGRAPH One scanner recalled over ice blockage in magnet venting system

    Siemens is recalling one BIOGRAPH One (DE) system because an ice blockage in the magnet venting system could prevent helium escaping during a quench.

    Product
    BIOGRAPH One (DE). Model Number: 11689172.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2666-2025·2025-10-08

    MAGNETOM Verio Dot Upgrade systems recalled over magnet venting ice blockage

    Siemens is recalling 78 MAGNETOM Verio Dot Upgrade systems because an ice blockage in the magnet venting system could stop helium escaping during a quench.

    Product
    MAGNETOM Verio Dot Upgrade. Model Number: 10684334.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2656-2025·2025-10-08

    MAGNETOM Cima.X systems recalled over ice blockage in helium venting system

    Siemens is recalling 22 MAGNETOM Cima.X (DE) systems because an ice blockage in the magnet venting system could prevent helium escaping during a quench.

    Product
    MAGNETOM Cima.X (DE). Model Number: 11647158.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2667-2025·2025-10-08

    MAGNETOM Vida MRI systems recalled over ice blockage in magnet venting

    Siemens is recalling 498 MAGNETOM Vida (DE) MRI systems because an ice blockage in the magnet venting system could stop helium escaping during a quench.

    Product
    MAGNETOM Vida (DE). Model Number: 11060815. 510(k): K170396, K173617, K181433, K183254, K192924, K203443, K213693, K213805, K220425, K231560.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2665-2025·2025-10-08

    MAGNETOM Verio Dot systems recalled over magnet venting ice blockage risk

    Siemens is recalling 59 MAGNETOM Verio Dot systems because an ice blockage in the magnet venting system could stop helium escaping during a quench.

    Product
    MAGNETOM Verio Dot. Model Number: 10684333.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2662-2025·2025-10-08

    MAGNETOM Skyra Fit BioMatrix systems recalled over magnet vent ice blockage

    Siemens is recalling 39 MAGNETOM Skyra Fit BioMatrix systems because an ice blockage in the magnet venting system could stop helium escaping during a quench.

    Product
    MAGNETOM Skyra Fit BioMatrix. Model Number: 11516217.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2668-2025·2025-10-08

    MAGNETOM Vida Fit MRI systems recalled over magnet vent ice blockage

    Siemens is recalling 41 MAGNETOM Vida Fit MRI systems because an ice blockage in the magnet venting system could stop helium escaping during a quench.

    Product
    MAGNETOM Vida Fit. Model Number: 11410481.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2659-2025·2025-10-08

    MAGNETOM Prisma MRI systems recalled over helium venting ice blockage

    Siemens is recalling 101 MAGNETOM Prisma MRI systems because an ice blockage in the magnet venting system could prevent helium escaping during a quench.

    Product
    MAGNETOM Prisma. Model Number: 10849582.
    Category
    Medical Device
    Distribution
    Distributed nationwide