The Recall Desk

Hazard

Electrical Short recalls

382 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
382
Critical
0
Severe
236
Most recent
2026-08-21

Of the 382 electrical short recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 236 (62%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all electrical short recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

301–325 of 382

  • HighCPSC·14106·2014-02-18

    LEM 5-Tray Food Dehydrators Recalled for Electrical Shock Hazard

    LEM Products is expanding a recall of 5-tray food dehydrators due to damaged wiring that poses a shock hazard. Consumers should stop using the units and contact the company for repair.

    Product
    5-Tray Dehydrators with Digital Timers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V052000·2014-02-12

    Nissan Recalls 2012-2014 Frontier Vehicles for Wiring Fire Risk

    Nissan is recalling 2012-2014 Frontier vehicles because an incorrectly installed circuit breaker may cause a wire harness to contact a metal bolt, potentially leading to an electrical short and fire.

    Product
    NISSAN — NISSAN FRONTIER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V019000·2014-01-27

    Turtle Top Recalls Ford-Based Transit Buses Due to Electrical Fire Risk

    Turtle Top is recalling 453 Ford-based transit buses because a pinched alternator harness could cause a short circuit, fire, or vehicle stall.

    Product
    TURTLE TOP — TURTLE TOP FORD VAN TERRA, FORD LIMO COACH, FORD ODYSSEY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·13V568000·2013-11-14

    Volkswagen Recalls 2013-2014 Jetta Hybrid Vehicles for Gearbox Corrosion

    Volkswagen is recalling 2013-2014 Jetta Hybrid vehicles because gearbox corrosion may cause an electrical short and sudden loss of power, increasing crash risk.

    Product
    VOLKSWAGEN — VOLKSWAGEN JETTA HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·13V566000·2013-11-13

    GM Recalls 2013 Chevrolet Malibu for Power Seat Wiring Fire Risk

    General Motors is recalling 2013 Chevrolet Malibus with 8-way power seats because the wiring harness may chafe, potentially causing a short circuit or fire.

    Product
    CHEVROLET — CHEVROLET MALIBU
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V534000·2013-10-29

    Prevost Recalls 2008-2009 Coach Buses Due to Battery Cable Fire Risk

    Prevost is recalling 142 model year 2008-2009 X3-45 and X3-45 Entertainer coach buses because a battery cable may rub against a clamp, causing a short circuit and potential vehicle fire.

    Product
    PREVOST — PREVOST XLII-45 ENTERTAINER, X3-45
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·13V521000·2013-10-17

    Nissan Recalls 2013 NV200 Vehicles for Wiring Harness Defect

    Nissan is recalling 2,529 model year 2013 NV200 vehicles because a wiring harness may wear through its covering, potentially causing a short circuit that stops the engine while driving.

    Product
    NISSAN — NISSAN redundant NV200
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0833-2013·2013-08-14

    Ventana BenchMark ULTRA Staining Platform Recalled for Fluid Overflow Risk

    Ventana Medical Systems is recalling 1,735 BenchMark ULTRA automated staining platforms due to a potential waste fluid overflow that could cause electrical shorting.

    Product
    VENTANA (a member of the Roche Group) BenchMark ULTRA; REF/MU 750-600; Research Use Only Product Usage: Research Use Only-The DISCOVERY ULTRA Advanced Staining System is intended to automatically stain histological or cytological specimens on microscope slides with specific
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1647-2013·2013-07-10

    Ortho-Clinical Diagnostics Recalls VITROS 5,1 FS Chemistry Systems Due to Electrical Short

    Ortho-Clinical Diagnostics is recalling 101 VITROS 5,1 FS Chemistry Systems because an electrical short can cause heat accumulation and melted wiring.

    Product
    1) VITROS 5,1 FS Chemistry System (product code 6801375) and 2) VITROS 5,1 FS Chemistry System Refurbished (product code 6801890) Product Usage: For use in the in vitro quantitative, semi-quantitative, and qualitative measurement of a variety of analytes of clinical interest
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1650-2013·2013-07-10

    Ortho-Clinical VITROS 3600 Immunodiagnostic System Recalled for Electrical Short

    Ortho-Clinical Diagnostics is recalling VITROS 3600 Immunodiagnostic Systems because an electrical short caused heat accumulation that melted wiring and connectors.

    Product
    VITROS 3600 Immunodiagnostic System (product code 6802783) Product Usage: For use in the in vitro quantitative, semi-quantitative, and qualitative measurement of a variety of analytes of clinical interest, using VITROS Immunodiagnostic Products Reagents
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1648-2013·2013-07-10

    Ortho-Clinical VITROS 4600 Chemistry System Recalled for Electrical Short

    Ortho-Clinical Diagnostics is recalling VITROS 4600 Chemistry Systems because an electrical short in the connector caused heat accumulation and melted wiring.

    Product
    VITROS 4600 Chemistry System (VITROS 5,1 FS System family member)(product code 6802445) Product Usage: For use in the in vitro quantitative measurement of a variety of analytes of clinical interest, using both VITROS Chemistry Products Slides (colorimetric endpoint, rate, io
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1649-2013·2013-07-10

    Ortho-Clinical VITROS 5600 Integrated System Recalled for Electrical Short

    Ortho-Clinical Diagnostics is recalling VITROS 5600 Integrated Systems due to an electrical short that caused heat accumulation and melted wiring.

    Product
    VITROS 5600 Integrated System (product code 6802413) Product Usage: For use in the in vitro quantitative, semi-quantitative, and qualitative measurement of a variety of analytes of clinical interest, using VITROS Chemistry Products Slides, VITROS Chemistry Products MicroTip
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1651-2013·2013-07-10

    Ortho Assay Software Server Recalled Due to Electrical Short and Heat

    Ortho-Clinical Diagnostics is recalling 31 units of the ORTHO Assay Software Server because an electrical short caused heat accumulation and melted wiring.

    Product
    ORTHO¿ Assay Software (OAS) Server, Catalog # 6842840 Usage: The ORTHO¿ Summit System (OSS) is a modular, integrated system for use with licensed blood screening tests. Consisting of networked processors and instruments linked together via a local area network, assay-specific
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V294000·2013-07-05

    TCI Recalls Two School Bus Models Due to Wheelchair Lift Fire Risk

    TCI is recalling two school bus models because a wheelchair lift cable may not clear the lift, potentially causing a short circuit and fire.

    Product
    TCI — TCI DW6159RLSST, SC159DSFP600
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1580-2013·2013-07-03

    Medtronic SynchroMed EL Pumps Recalled for Electrical Shorting Risk

    Medtronic is recalling SynchroMed EL pumps due to potential internal electrical shorting that may cause therapy loss.

    Product
    Medtronic SynchroMed EL Programmable pumps, Models 8626, 8626L, 8627, 8627L, (The SynchroMed EL Pumps are supplied in 10 ml or 18 ml reservoir size.) Sterilized using ethylene oxide. The pump is part of an infusion system that stores and delivers a prescribed drug to a specific s
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1579-2013·2013-07-03

    Medtronic SynchroMed II Pumps Recalled for Electrical Shorting Risk

    Medtronic is recalling SynchroMed II pumps due to potential electrical shorting that may cause therapy loss or reduction.

    Product
    Medtronic SynchroMed II, Model 8637, (The SynchroMed II Pump is supplied in 20 ml or 40 ml reservoir size.) Sterilized using ethylene oxide. The pump is part of an infusion system that stores and delivers a prescribed drug to a specific site. The implantable components of the Syn
    Category
    Medical Device
    Distribution
    0 states
  • HighNHTSA·13V263000·2013-06-24

    Turtle Top Recalls Wheelchair Lifts on Ford Odyssey Vehicles

    Turtle Top is recalling certain 2007-2012 Ford Odyssey, Terra Transport, and Van Terra vehicles equipped with Ricon wheelchair lifts. An armored cable may not clear the lift, potentially causing a short circuit and fire.

    Product
    TURTLE TOP — TURTLE TOP FORD ODYSSEY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V253000·2013-06-21

    Elkhart Coach Shuttle Bus Recall for Wheelchair Lift Fire Risk

    Elkhart Coach is recalling 2006-2012 shuttle buses because a wheelchair lift cable may cause a short circuit and fire.

    Product
    ELKHART COACH — ELKHART COACH SHUTTLE BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V248000·2013-06-13

    GM Recalls 2005-2007 SUVs for Door Module Fire Risk

    General Motors is recalling approximately 193,652 vehicles from 2005-2007 due to a driver's door module defect that could cause a fire.

    Product
    GMC — GMC, ISUZU, SAAB ENVOY, ASCENDER, 9-7X, TRAILBLAZER EXT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V224000·2013-05-29

    Altec Aerial Devices Recalled for Battery Cable Fire Risk

    Altec is recalling 2010-2012 aerial devices because a battery cable could short to ground and cause a fire.

    Product
    ALTEC — ALTEC AT248F, AT235P, AT237, AT35-G
    Category
    Vehicle
    Distribution
    Distributed nationwide