54 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
54
Critical
0
Severe
6
Most recent
2026-10-14

Of the 54 cybersecurity vulnerability recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 6 (11%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all cybersecurity vulnerability recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–25 of 54

  • ModerateFDA (Devices)·Z-0089-2027·2026-10-14

    Nihon Kohden CNS-6200 Central Nurse Station Recalled for Cybersecurity Vulnerability

    Nihon Kohden America LLC is recalling 808 CNS-6200 Series Central Nurse Stations due to a cybersecurity vulnerability that could disrupt patient monitoring.

    Product
    Product Name: Nihon Kohden CNS-6200 Series Central Nurse Station, Model/Catalog Number: CN-6201 Software Version: software versions: 01-03, 01-04, 01-05, 01-06, 02-10, 02-11, and 02-40 Product Description: The device is intended for use by medical professionals to provide…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2878-2026·2026-08-12

    GE Healthcare Portrait Core Services Software Recall Due to Software Vulnerability

    GE Medical Systems Information Technologies Inc is recalling GE Healthcare Portrait Core Services SW V 1.2.0 (REF 5700592) patient monitoring systems due to a software vulnerability.

    Product
    GE Healthcare Portrait Core Services SW V 1.2.0, REF 5700592. patient monitoring system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2717-2026·2026-07-15

    Versius Surgical System Console affected by cybersecurity vulnerability

    CMR Surgical Limited is recalling the Versius Surgeon Console (Model V-SS-1020, Software Version Pratchett 1 version 62.1) due to Secure Boot not being enabled at manufacturing, presenting a potential cybersecurity risk.

    Product
    Brand Name: Versius Surgical System US Product Name: Vesius Surgeon Console US Model/Catalog Number: V-SS-1020 Software Version: Pratchett 1 version 62.1 Product Description: The Versius Surgical System is a modular, open console, software controlled, electromechanical…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1826-2026·2026-05-06

    WHILL Model C2 Powered Wheelchair Recalled for Bluetooth Security Vulnerability

    WHILL Model C2 powered wheelchairs with software versions before HMI 2.22 and MC 1.13 are recalled due to a Bluetooth Low Energy (BLE) communication vulnerability identified by CISA. Approximately 4,685 units distributed in Kansas are affected.

    Product
    WHILL Model C2, with software versions before HMI: 2.22 / MC: 1.13; device is an indoor/outdoor battery-operated 2-wheel drive (rear-wheel drive) powered wheelchair.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1570-2026·2026-03-25

    GE Centricity Viewer 6.0 may expose login credentials on workstations

    GE Medical Systems is recalling Centricity Universal Viewer software versions 6.0 through 6.0 SP10.4.1 because user login credentials may be exposed on the local client workstation.

    Product
    Centricity Universal Viewer Software Versions 6.0 through 6.0 Sp10.4.1, a device that displays medical images (including mammograms) and data from various imaging sources, Model Numbers 2088026-406, 2100169-001, 2088026-985, 2088026-971, 2088026-614, 2088026-713, 2088026-994…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1571-2026·2026-03-25

    GE Centricity Viewer 5.0 may expose login credentials on workstations

    GE Medical Systems is recalling Centricity Universal Viewer software versions 5.0 SP6 through 5.0 SP7.1 because user login credentials may be exposed on the local client workstation.

    Product
    Centricity Universal Viewer Software Versions 5.0 SP6 through UV 5.0 SP7.1, a device that displays medical images (including mammograms) and data from various imaging sources, Model Numbers 2088026-026, 2088026-115, 2088026-043, K2042VJED, 2088026-132, 2088026-003, 2088026-110…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1569-2026·2026-03-25

    GE Centricity Viewer 7.0 may expose login credentials on workstations

    GE Medical Systems is recalling Centricity Universal Viewer software versions 7.0 through 7.0 SP2.0.1 because user login credentials may be exposed on the local client workstation.

    Product
    Centricity Universal Viewer Software Versions 7.0 through 7.0 Sp2.0.1, a device that displays medical images (including mammograms) and data from various imaging sources, Model Numbers 5826659-027, 5826659-029, 5826659-032, 5826659-033, 5826659-028, 5826659-034, 5826659-030…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1726-2025·2025-05-21

    Welch Allyn Life2000 Compressor recalled for cybersecurity vulnerability

    Baxter Healthcare Corporation is recalling Welch Allyn Life2000 Compressor units due to a cybersecurity vulnerability discovered during internal testing.

    Product
    Welch Allyn Life2000 Compressor, Product Codes: 1) BT-80-0004; 2) BT-80-0004A; 3) BT-80-0008; 4) BT-80-0008A; 5) RMS010093CP.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1725-2025·2025-05-21

    Welch Allyn Life2000 Ventilation System Recalled for Cybersecurity Vulnerability

    Baxter Healthcare Corporation is recalling the Welch Allyn Life2000 Ventilation system due to a cybersecurity vulnerability discovered through internal testing. The recall affects 4,881 units distributed worldwide.

    Product
    Welch Allyn Life2000 Ventilation system, Product Codes: 1) BT-20-0002; 2) BT-20-0002A; 3) BT-20-0002AP; 4) BT200007; 5) BT-20-0007; 6) BT200011; 7) BT-20-0011; 8) RMS010118CP.
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-1764-2025·2025-05-21

    CMS8000 Patient Monitor Has Nine Cybersecurity Vulnerabilities

    The CMS8000 Patient Monitor manufactured by Contec Medical Systems Co., Ltd. has nine identified cybersecurity vulnerabilities. The FDA is issuing this Class II recall affecting approximately 7,773 units distributed nationwide.

    Product
    CMS8000 Patient Monitor
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0594-2025·2024-12-11

    BD BACTEC FX40 Product Service Credentials Accessed by Unauthorized Actor

    Unauthorized actor accessed BD technical support credentials for the BACTEC FX40 laboratory instrument. Until credentials are updated, there is a risk of unauthorized access to the system and associated data.

    Product
    BD BACTEC FX40 Instrument Version or Model: 442296 Catalog Number: 442296
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0990-2024·2024-02-14

    Flow-c Anesthesia System cybersecurity vulnerability in 14 units

    The Flow-c Anesthesia System model 6887700 has a cybersecurity vulnerability allowing potential denial of service, tampering, or remote code execution via remote login. Fourteen units were distributed in the United States.

    Product
    Flow-c Anesthesia System, model 6887700
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0991-2024·2024-02-14

    Flow-e Anesthesia System Model 6887900 Cybersecurity Vulnerability Recall

    The Flow-e Anesthesia System model 6887900 is recalled due to a cybersecurity vulnerability that could allow remote access, denial of service, or code execution, potentially affecting anesthesia delivery safety.

    Product
    Flow-e Anesthesia System, model 6887900
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0988-2024·2024-02-14

    Anesthesia System Cybersecurity Vulnerability Poses Denial of Service Risk

    The Flow-i C30 Anesthesia System contains a cybersecurity vulnerability allowing remote attackers to cause denial of service, tampering, or code execution, potentially creating hazardous conditions.

    Product
    Flow-i C30 Anesthesia System, model 6677300
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0989-2024·2024-02-14

    Flow-i C40 Anesthesia System Recalled for Cybersecurity Vulnerability

    Getinge's Flow-i C40 Anesthesia System (model 6677400) contains a potential cybersecurity vulnerability allowing remote login attacks that could result in denial of service, system tampering, or remote code execution.

    Product
    Flow-i C40 Anesthesia System, model 6677400
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1976-2023·2023-06-28

    NextSeq 550Dx sequencing instruments recalled for cybersecurity software vulnerability

    Illumina is recalling 1,067 NextSeq 550Dx sequencing instruments due to a cybersecurity vulnerability in the Universal Copy Service software. The affected instruments have been distributed worldwide.

    Product
    NextSeq 550Dx Instrument, Catalog # 20005715, contaning Universal Copy Service software
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1977-2023·2023-06-28

    FDA Recalls MiSeq Dx Instruments for Software Cybersecurity Vulnerability

    Illumina recalls 740 MiSeq Dx sequencing instruments due to a software cybersecurity vulnerability affecting the Universal Copy Service component. No patient harm reported.

    Product
    MiSeq Dx Instrument, Catalog # M70101, containing Universal Copy Service (UCS) software.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0194-2023·2022-11-16

    Insulin Pump Cybersecurity Vulnerability Allows Unauthorized Remote Access

    MiniMed 600 series insulin pumps have a cybersecurity vulnerability that could allow unauthorized access, potentially resulting in delivery of too much or too little insulin. Users should disable the Remote Bolus feature.

    Product
    Insulin Pump/Model: MiniMed 620G/ MMT-1750 MiniMed 640G/ MMT-1711, MMT-1712, MMT-1751, MMT-1752
    Category
    Medical Device
    Distribution
    54 states
  • HighFDA (Devices)·Z-0193-2023·2022-11-16

    Medtronic MiniMed Insulin Pumps Recalled for Cybersecurity Vulnerability

    Medtronic is recalling MiniMed 630G and 670G insulin pumps due to a cybersecurity vulnerability that could allow unauthorized access to the pump system, potentially resulting in incorrect insulin delivery.

    Product
    Insulin Pump/Model: MiniMed 630G/ MMT-1715, MMT-1755, MMT-1754; MiniMed 670G/ MMT-1780, MMT-1781, MMT-1782, MMT-1760, MMT-1761, MMT-1762, MMT-1740, MMT-1741, MMT-1742
    Category
    Medical Device
    Distribution
    54 states
  • HighFDA (Devices)·Z-1259-2022·2022-06-22

    Illumina MiSeq Dx Sequencing Instruments Recalled Due to Cybersecurity Vulnerability

    Illumina is recalling approximately 1,014 MiSeq Dx sequencing instruments due to a cybersecurity vulnerability. The devices are distributed worldwide and throughout the United States.

    Product
    illumina REF DX-410-1001 Model: MiSeq Dx illumina REF 15036706 Model: MiSeq Dx illumina REF 20014053 Model: MiSeq Dx
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1260-2022·2022-06-22

    Illumina NextSeq 550 Genetic Sequencer Cybersecurity Vulnerability Recall

    Illumina is recalling 799 NextSeq 550 Dx genetic sequencers due to a cybersecurity vulnerability in the Local Run Manager software. Affected devices have been distributed worldwide and in the United States.

    Product
    illumina Model NextSeq 550 Dx REF 20005715
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0870-2022·2022-04-13

    Draeger Evita V500 Ventilator Cybersecurity Vulnerability Affects Patient Safety

    Draeger Medical is recalling Evita V500 ventilators due to cybersecurity vulnerabilities that could potentially compromise device functionality. Affected units require software remediation.

    Product
    Evita V500 Ventilator with Software 2.51.01 and Lower - intended for the ventilation of adult, pediatric and neonatal patients Catalog Number: 8416400
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0871-2022·2022-04-13

    Draeger Babylog VN500 Ventilators Recalled for Cybersecurity Vulnerability

    Draeger Medical is recalling Babylog VN500 ventilators for neonatal and pediatric patients due to cybersecurity vulnerabilities. The devices are not equipped against potential cyber threats.

    Product
    Babylog VN500 Ventilator with Software 2.51.01 and Lower- intended for the ventilation neonatal patients from 0.4 kg (0.88 lbs) up to 10 kg (22 lbs) and pediatric patients from 5 kg (11 lbs) up to 20 kg (44 lbs) bodyweight Catalog Number: 8417400
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1506-2021·2021-05-05

    Datascope Cardiosave Hybrid IABP Recalled for Cybersecurity Vulnerabilities

    Datascope Corp. is recalling Cardiosave Hybrid IABP devices due to cybersecurity vulnerabilities in a TCP/IP software library that may cause loss of communication to hospital systems.

    Product
    Cardiosave Hybrid IABP - Product Usage: used to inflate and deflate intra-aortic balloons. It provides temporary support to the left ventricle via the principle of counterpulsation, Model Numbers 0998-00-0800-32, 0998-00-0800-33, 0998-00-0800-34, 0998-00-0800-35…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1507-2021·2021-05-05

    Datascope Cardiosave Rescue IABP Recalled for Cybersecurity Vulnerabilities

    Datascope Corp. is recalling Cardiosave Rescue IABP units due to cybersecurity vulnerabilities in a TCP/IP software library that may cause loss of communication to hospital systems.

    Product
    Cardiosave Rescue IABP - Product Usage: used to inflate and deflate intra-aortic balloons. It provides temporary support to the left ventricle via the principle of counterpulsation, Model Numbers 0998-00-0800-75, 0998-00-0800-83, 0998-00-0800-85
    Category
    Medical Device
    Distribution
    Distributed nationwide